Researcher profile

Michael Lustig

Michael Lustig contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
11works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

11 published item(s)

preprint2022arXiv

Rapid Fabrication of Low Impedance, 3D Dry Electrodes for Physiological Sensing

Medical electrophysiological sensors that can study the body and diagnose diseases depend on consistently low impedance electrode-skin interfaces. Clinical-standard wet electrodes use hydrogels and skin abrasion to improve the interface and thus the recorded signal quality. These electrodes are challenging to self-administer and impede in-home care. Wearable dry electrodes are more practical; however, they show higher impedances than wet electrodes and are costly to customize. This work presents a fabrication method for rapidly producing low impedance, anatomically fit dry electrodes that do not require hydrogels. By using electroless copper and gold plating with 3D printing, biocompatible electrodes can be optimized for individuals at a fraction of the cost of existing vacuum deposition-based techniques. Example 3D dry electrodes made with this process are evaluated alongside clinical-standard devices in typical scenarios to compare electrical performance and comfort. The resulting dry electrodes exhibited an average electrode-skin impedance of 66.7 kΩ at 50Hz and DC offset of -20 mV without any hydrogel, which, when area normalized, is within the range achieved by wet electrodes without skin abrasion.

preprint2021arXiv

Memory-efficient Learning for High-Dimensional MRI Reconstruction

Deep learning (DL) based unrolled reconstructions have shown state-of-the-art performance for under-sampled magnetic resonance imaging (MRI). Similar to compressed sensing, DL can leverage high-dimensional data (e.g. 3D, 2D+time, 3D+time) to further improve performance. However, network size and depth are currently limited by the GPU memory required for backpropagation. Here we use a memory-efficient learning (MEL) framework which favorably trades off storage with a manageable increase in computation during training. Using MEL with multi-dimensional data, we demonstrate improved image reconstruction performance for in-vivo 3D MRI and 2D+time cardiac cine MRI. MEL uses far less GPU memory while marginally increasing the training time, which enables new applications of DL to high-dimensional MRI.

preprint2020arXiv

Extreme MRI: Large-Scale Volumetric Dynamic Imaging from Continuous Non-Gated Acquisitions

Purpose: To develop a framework to reconstruct large-scale volumetric dynamic MRI from rapid continuous and non-gated acquisitions, with applications to pulmonary and dynamic contrast enhanced (DCE) imaging. Theory and Methods: The problem considered here requires recovering hundred-gigabytes of dynamic volumetric image data from a few gigabytes of k-space data, acquired continuously over several minutes. This reconstruction is vastly under-determined, heavily stressing computing resources as well as memory management and storage. To overcome these challenges, we leverage intrinsic three dimensional (3D) trajectories, such as 3D radial and 3D cones, with ordering that incoherently cover time and k-space over the entire acquisition. We then propose two innovations: (1) A compressed representation using multi-scale low rank matrix factorization that constrains the reconstruction problem, and reduces its memory footprint. (2) Stochastic optimization to reduce computation, improve memory locality, and minimize communications between threads and processors. We demonstrate the feasibility of the proposed method on DCE imaging acquired with a golden-angle ordered 3D cones trajectory and pulmonary imaging acquired with a bit-reversed ordered 3D radial trajectory. We compare it with "soft-gated" dynamic reconstruction for DCE and respiratory resolved reconstruction for pulmonary imaging. Results: The proposed technique shows transient dynamics that are not seen in gating based methods. When applied to datasets with irregular, or non-repetitive motions, the proposed method displays sharper image features. Conclusion: We demonstrated a method that can reconstruct massive 3D dynamic image series in the extreme undersampling and extreme computation setting.

preprint2020arXiv

How to do Physics-based Learning

The goal of this tutorial is to explain step-by-step how to implement physics-based learning for the rapid prototyping of a computational imaging system. We provide a basic overview of physics-based learning, the construction of a physics-based network, and its reduction to practice. Specifically, we advocate exploiting the auto-differentiation functionality twice, once to build a physics-based network and again to perform physics-based learning. Thus, the user need only implement the forward model process for their system, speeding up prototyping time. We provide an open-source Pytorch implementation of a physics-based network and training procedure for a generic sparse recovery problem

preprint2020arXiv

Iterative Motion Compensation reconstruction ultra-short TE(iMoCo UTE) for high resolution free breathing pulmonary MRI

Purpose, To develop a high scanning efficiency, motion corrected imaging strategy for free-breathing pulmonary MRI by combining a motion compensation reconstruction with a UTE acquisition, called iMoCo UTE. Methods, An optimized golden angle ordering radial UTE sequence was used to continuously acquire data for 5 minutes. All readouts were grouped to different respiratory motion states based on self-navigator signals, then motion resolved data was reconstructed by XD Golden angle RAdial Sparse Parallel reconstruction (XD GRASP). One state from the motion resolved images was selected as a reference, and motion fields from the other states to the reference were derived via non-rigid registration. Finally, all motion resolved data and motion fields were reconstructed by using an iterative motion compensation reconstruction with a total generalized variation sparse constraint. Results, The iMoCo UTE strategy was evaluated in volunteers and non-sedated pediatric patient(4-6 y/o) studies. Images reconstructed with iMoCo UTE provided sharper anatomical lung structures, and higher apparent SNR and CNR, compared to using other motion correction strategies, such as soft-gating, motion resolved reconstruction, and non-rigid motion compensation(MoCo). iMoCo UTE also showed promising results in an infant study. Conclusions, The proposed iMoCo UTE combines self-navigation, motion modeling, and a compressed sensing reconstruction to increase scan efficiency, SNR, and reduce respiratory motion in lung MRI. This proposed strategy shows improvements in free breathing lung MRI scans, especially in very challenging application situations, such as pediatric MRI studies.

preprint2020arXiv

Memory-efficient Learning for Large-scale Computational Imaging

Critical aspects of computational imaging systems, such as experimental design and image priors, can be optimized through deep networks formed by the unrolled iterations of classical model-based reconstructions (termed physics-based networks). However, for real-world large-scale inverse problems, computing gradients via backpropagation is infeasible due to memory limitations of graphics processing units. In this work, we propose a memory-efficient learning procedure that exploits the reversibility of the network's layers to enable data-driven design for large-scale computational imaging systems. We demonstrate our method on a small-scale compressed sensing example, as well as two large-scale real-world systems: multi-channel magnetic resonance imaging and super-resolution optical microscopy.

preprint2020arXiv

Memory-efficient Learning for Large-scale Computational Imaging -- NeurIPS deep inverse workshop

Computational imaging systems jointly design computation and hardware to retrieve information which is not traditionally accessible with standard imaging systems. Recently, critical aspects such as experimental design and image priors are optimized through deep neural networks formed by the unrolled iterations of classical physics-based reconstructions (termed physics-based networks). However, for real-world large-scale systems, computing gradients via backpropagation restricts learning due to memory limitations of graphical processing units. In this work, we propose a memory-efficient learning procedure that exploits the reversibility of the network's layers to enable data-driven design for large-scale computational imaging. We demonstrate our methods practicality on two large-scale systems: super-resolution optical microscopy and multi-channel magnetic resonance imaging.

preprint2020arXiv

SURE-based Automatic Parameter Selection For ESPIRiT Calibration

Purpose: Parallel imaging methods in MRI have resulted in faster acquisition times and improved noise performance. ESPIRiT is one such technique that estimates coil sensitivity maps from the auto-calibration region using an eigenvalue-based method. This method requires choosing several parameters for the the map estimation. Even though ESPIRiT is fairly robust to these parameter choices, occasionally, poor selection can result in reduced performance. The purpose of this work is to automatically select parameters in ESPIRiT for more robust and consistent performance across a variety of exams. Theory and Methods: Stein's unbiased risk estimate (SURE) is a method of calculating an unbiased estimate of the mean squared error of an estimator under certain assumptions. We show that this can be used to estimate the performance of ESPIRiT. We derive and demonstrate the use of SURE to optimize ESPIRiT parameter selection. Results: Simulations show SURE to be an accurate estimator of the mean squared error. SURE is then used to optimize ESPIRiT parameters to yield maps that are optimal in a denoising/data-consistency sense. This improves g-factor performance without causing undesirable attenuation. In-vivo experiments verify the reliability of this method. Conclusion: Simulation experiments demonstrate that SURE is an accurate estimate of expected mean squared error. Using SURE to determine ESPIRiT parameters allows for automatic parameter selections.In-vivo results are consistent with simulation and theoretical results.

preprint2020arXiv

Unsupervised Deep Basis Pursuit: Learning inverse problems without ground-truth data

Basis pursuit is a compressed sensing optimization in which the l1-norm is minimized subject to model error constraints. Here we use a deep neural network prior instead of l1-regularization. Using known noise statistics, we jointly learn the prior and reconstruct images without access to ground-truth data. During training, we use alternating minimization across an unrolled iterative network and jointly solve for the neural network weights and training set image reconstructions. At inference, we fix the weights and pass the measurements through the network. We compare reconstruction performance between unsupervised and supervised (i.e. with ground-truth) methods. We hypothesize this technique could be used to learn reconstruction when ground-truth data are unavailable, such as in high-resolution dynamic MRI.

preprint2019arXiv

Accelerating Non-Cartesian MRI Reconstruction Convergence using k-space Preconditioning

We propose a k-space preconditioning formulation for accelerating the convergence of iterative Magnetic Resonance Imaging (MRI) reconstructions from non-uniformly sampled k-space data. Existing methods either use sampling density compensations which sacrifice reconstruction accuracy, or circulant preconditioners which increase per-iteration computation. Our approach overcomes both shortcomings. Concretely, we show that viewing the reconstruction problem in the dual formulation allows us to precondition in k-space using density-compensation-like operations. Using the primal-dual hybrid gradient method, the proposed preconditioning method does not have inner loops and are competitive in accelerating convergence compared to existing algorithms. We derive l2-optimized preconditioners, and demonstrate through experiments that the proposed method converges in about ten iterations in practice.

preprint2019arXiv

Computational MRI with Physics-based Constraints: Application to Multi-contrast and Quantitative Imaging

Compressed sensing takes advantage of low-dimensional signal structure to reduce sampling requirements far below the Nyquist rate. In magnetic resonance imaging (MRI), this often takes the form of sparsity through wavelet transform, finite differences, and low rank extensions. Though powerful, these image priors are phenomenological in nature and do not account for the mechanism behind the image formation. On the other hand, MRI signal dynamics are governed by physical laws, which can be explicitly modeled and used as priors for reconstruction. {1}These explicit and implicit signal priors can be synergistically combined in an inverse problem framework to recover sharp, multi-contrast images from highly accelerated scans. Furthermore, the physics-based constraints provide a recipe for recovering quantitative, bio-physical parameters from the data. This article introduces physics-based modeling constraints in MRI and shows how they can be used in conjunction with compressed sensing for image reconstruction and quantitative imaging. We describe model-based quantitative MRI, as well as its linear subspace approximation. We also discuss approaches to selecting user-controllable scan parameters given knowledge of the physical model. We present several MRI applications that take advantage of this framework for the purpose of multi-contrast imaging and quantitative mapping.