Source author record

Markus Kuster

Markus Kuster appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

12works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

12 published item(s)

preprint2016arXiv

Performance of the LBNL FastCCD for the European XFEL

The European X-ray Free Electron Laser (XFEL.EU) is currently being commissioned in Schenefeld, Germany. From 2017 onwards it will provide spatially coherent X-rays of energies between 0.25\,keV and 25\,keV with a unique timing structure. One of the detectors foreseen at XFEL.EU for the soft X-ray regime (energies below 6\,keV) is a quasi column-parallel readout FastCCD developed by Lawrence Berkeley National Lab (LBNL) specifically for the XFEL.EU requirements. Its sensor has 1920$\times$960 pixels of 30\,$μ$m $\times$30\,$μ$m size with a beam hole in the middle of the sensor. The camera can be operated in full frame and frame store mode. With the FastCCD a frame rate of up to 120~fps can be achieved, but at XFEL.EU the camera settings are optimized for the 10\,Hz XFEL bunch-mode. The detector has been delivered to XFEL.EU. Results of the performance tests and calibration done using the XFEL.EU detector calibration infrastructure are presented quantifying noise level, gain and energy resolution.

preprint2016arXiv

Safety-Interlock System of the DSSC X-Ray Imager

In this paper, the DSSC safety-interlock system is introduced. It is designed to keep the DSSC mega-pixel camera in a safe-state. The system is composed of four inter-communicating sub-systems referred here as a master SIB (safety-interlock board) and three partner SIBs. Each SIB monitors and processes 75 temperature sensors mainly located in the focal plane and also distributed inside the camera-head electronics. It monitors the signals from two pressure sensors, one humidity sensor as well as the connectivity to sixteen low-voltage and two high-voltage cables. The master SIB supervises the signals to and from external equipments like the cooling system, pressure gauge, power crates and status information from experimental environment. SIB is an 8-layer printed-circuit board (PCB) with a micro-controller sitting on top as its central processing unit. A decision-matrix software reads the sensor status continuously and determines whether the camera is in a safe state or not. All error and warnings flags are sent to the detector control software framework and the end user directly. These flags are also stored every 100 ms together with the image data. The full SIB sensor data is sent to the back end for offline analysis. A shutdown sequence is initiated by SIB in case of a critical failure. The safety-interlock philosophy, hardware design, and software architecture along with test results will be presented.

preprint2015arXiv

X-CSIT: a toolkit for simulating 2D pixel detectors

A new, modular toolkit for creating simulations of 2D X-ray pixel detectors, X-CSIT (X-ray Camera SImulation Toolkit), is being developed. The toolkit uses three sequential simulations of detector processes which model photon interactions, electron charge cloud spreading with a high charge density plasma model and common electronic components used in detector readout. In addition, because of the wide variety in pixel detector design, X-CSIT has been designed as a modular platform so that existing functions can be modified or additional functionality added if the specific design of a detector demands it. X-CSIT will be used to create simulations of the detectors at the European XFEL, including three bespoke 2D detectors: the Adaptive Gain Integrating Pixel Detector (AGIPD), Large Pixel Detector (LPD) and DePFET Sensor with Signal Compression (DSSC). These simulations will be used by the detector group at the European XFEL for detector characterisation and calibration. For this purpose, X-CSIT has been integrated into the European XFEL's software framework, Karabo. This will further make it available to users to aid with the planning of experiments and analysis of data. In addition, X-CSIT will be released as a standalone, open source version for other users, collaborations and groups intending to create simulations of their own detectors.

preprint2014arXiv

Geant4 and beyond: recent progress in precision physics modeling

This extended abstract briefly summarizes ongoing research activity on the evaluation and experimental validation of physics methods for photon and electron transport. The analysis includes physics models currently implemented in Geant4 as well as modeling methods used in other Monte Carlo codes, or not yet considered in general purpose Monte Carlo simulation systems. The validation of simulation models is performed with the support of rigorous statistical methods, which involve goodness-of-fit tests followed by categorical analysis. All results are quantitative, and are fully documented.

preprint2014arXiv

Validation of Compton Scattering Monte Carlo Simulation Models

Several models for the Monte Carlo simulation of Compton scattering on electrons are quantitatively evaluated with respect to a large collection of experimental data retrieved from the literature. Some of these models are currently implemented in general purpose Monte Carlo systems; some have been implemented and evaluated for possible use in Monte Carlo particle transport for the first time in this study. Here we present first and preliminary results concerning total and differential Compton scattering cross sections.

preprint2013arXiv

Performance of an LPD prototype detector at MHz frame rates under Synchrotron and FEL radiation

A MHz frame rate X-ray area detector (LPD - Large Pixel Detector) is under development by the Rutherford Appleton Laboratory for the European XFEL. The detector will have 1 million pixels and allows analogue storage of 512 images taken at 4.5 MHz in the detector front end. The LPD detector has 500 mm thick silicon sensor tiles that are bump bonded to a readout ASIC. The ASICs preamplifier provides relatively low noise at high speed which results in a high dynamic range of 10^5 photons over an energy range of 5-20 keV. Small scale prototypes of 32x256 pixels (LPD 2-Tile detector) and 256x256 pixels (LPD supermodule detector) are now available for X-ray tests. The performance of prototypes of the detector is reported for first tests under synchrotron radiation (PETRA III at DESY) and Free-Electron-Laser radiation (LCLS at SLAC). The initial performance of the detector in terms of signal range and noise, radiation hardness and spatial and temporal response are reported. The main result is that the 4.5 MHz sampling detection chain is reliably working, including the analogue on-chip memory concept. The detector is at least radiation hard up to 5 MGy at 12 keV. In addition the multiple gain concept has been demonstrated over a dynamic range to 10^4 at 12 keV with a readout noise equivalent to <1 photon rms in its most sensitive mode.

preprint2013arXiv

Radioactive Decays in Geant4

The simulation of radioactive decays is a common task in Monte-Carlo systems such as Geant4. Usually, a system either uses an approach focusing on the simulations of every individual decay or an approach which simulates a large number of decays with a focus on correct overall statistics. The radioactive decay package presented in this work permits, for the first time, the use of both methods within the same simulation framework - Geant4. The accuracy of the statistical approach in our new package, RDM-extended, and that of the existing Geant4 per-decay implementation (original RDM), which has also been refactored, are verified against the ENSDF database. The new verified package is beneficial for a wide range of experimental scenarios, as it enables researchers to choose the most appropriate approach for their Geant4-based application.

preprint2013arXiv

Status of detector development for the European XFEL

The European X-ray Free Electron Laser (XFEL.EU) will provide as-yet-unrivaled peak brilliance and ultra-short pulses of spatially coherent X-rays with a pulse length of less than 100 fs in the energy range between 0.25 and 25 keV. The high radiation intensity and ultra-short pulse duration will open a window for novel scientific techniques and will allow to explore new phenomena in biology, chemistry, material science, as well as matter at high energy density, atomic, ion and molecular physics. The variety of scientific applications and especially the unique XFEL.EU time structure require adequate instrumentation to be developed in order to exploit the full potential of the light source. To make optimal use of the unprecedented capabilities of the European XFEL and master these vast technological challenges, the European XFEL GmbH has started a detector R&D program. The technology concepts of the detector system presently under development are complementary in their performance and will cover the requirements of a large fraction of the scientific applications envisaged for the XFEL.EU facility. The actual status of the detector development projects which includes ultra-fast 2D imaging detectors, low repetition rate 2D detectors as well as strip detectors for e.g. spectroscopy applications and the infrastructure for the detectors' calibration and tests will be presented. Furthermore, an overview of the forthcoming implementation phase of the European XFEL in terms of detector R&D will be given.

preprint2013arXiv

Validation of Geant4-based Radioactive Decay Simulation

Radioactive decays are of concern in a wide variety of applications using Monte-Carlo simulations. In order to properly estimate the quality of such simulations, knowledge of the accuracy of the decay simulation is required. We present a validation of the original Geant4 Radioactive Decay Module, which uses a per-decay sampling approach, and of an extended package for Geant4-based simulation of radioactive decays, which, in addition to being able to use a refactored per-decay sampling, is capable of using a statistical sampling approach. The validation is based on measurements of calibration isotope sources using a high purity Germanium (HPGe) detector; no calibration of the simulation is performed. For the considered validation experiment equivalent simulation accuracy can be achieved with per-decay and statistical sampling.

preprint2012arXiv

Detector Development for the European XFEL: Requirements and Status

The variety of applications and especially the unique European XFEL time structure will require adequate instrumentation to be developed to exploit the full potential of the light source. Two-dimensional integrating X-ray detectors with ultra-fast read out up to 4.5 MHz for 1024 x 1024 pixel images are under development for a variety of imaging applications. The actual status of the European XFEL detector development projects is presented. Furthermore, an outlook will be given with respect to detector research and development, performance optimization, integration, and commissioning.

preprint2011arXiv

Background Simulations of the Wide Field Imager of the ATHENA X-Ray Observatory

The ATHENA X-ray Observatory-IXO is a planned multinational orbiting X-ray observatory with a focal length of 11.5m. ATHENA aims to perform pointed observations in an energy range from 0.1 keV to 15 keV with high sensitivity. For high spatial and timing resolution imaging and spectroscopic observations the 640x640 pixel^2 large DePFET-technology based Wide field Imager (WFI) focal plane detector, providing a field of view of 18 arcsec will be the main detector. Based on the actual mechanics, thermal and shielding design we present estimates for the WFI cosmic ray induced background obtained by the use of Monte-Carlo simulations and possible background reduction measures.