Researcher profile

Monica Turcato

Monica Turcato contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - Emerging
6works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2016arXiv

Review of Searches for Rare Processes and Physics Beyond the Standard Model at HERA

The electron-proton collisions collected by the H1 and ZEUS experiments at HERA comprise a unique particle physics data set, and a comprehensive range of measurements has been performed to provide new insight into the structure of the proton. The high centre of mass energy at HERA has also allowed rare processes to be studied, including the production of W and Z bosons and events with multiple leptons in the final state. The data have also opened up a new domain to searches for physics beyond the Standard Model including contact interactions, leptoquarks, excited fermions and a number of supersymmetric models. This review presents a summary of such results, where the analyses reported correspond to an integrated luminosity of up to 1 fb^-1, representing the complete data set recorded by the H1 and ZEUS experiments.

preprint2016arXiv

Safety-Interlock System of the DSSC X-Ray Imager

In this paper, the DSSC safety-interlock system is introduced. It is designed to keep the DSSC mega-pixel camera in a safe-state. The system is composed of four inter-communicating sub-systems referred here as a master SIB (safety-interlock board) and three partner SIBs. Each SIB monitors and processes 75 temperature sensors mainly located in the focal plane and also distributed inside the camera-head electronics. It monitors the signals from two pressure sensors, one humidity sensor as well as the connectivity to sixteen low-voltage and two high-voltage cables. The master SIB supervises the signals to and from external equipments like the cooling system, pressure gauge, power crates and status information from experimental environment. SIB is an 8-layer printed-circuit board (PCB) with a micro-controller sitting on top as its central processing unit. A decision-matrix software reads the sensor status continuously and determines whether the camera is in a safe state or not. All error and warnings flags are sent to the detector control software framework and the end user directly. These flags are also stored every 100 ms together with the image data. The full SIB sensor data is sent to the back end for offline analysis. A shutdown sequence is initiated by SIB in case of a critical failure. The safety-interlock philosophy, hardware design, and software architecture along with test results will be presented.

preprint2013arXiv

Performance of an LPD prototype detector at MHz frame rates under Synchrotron and FEL radiation

A MHz frame rate X-ray area detector (LPD - Large Pixel Detector) is under development by the Rutherford Appleton Laboratory for the European XFEL. The detector will have 1 million pixels and allows analogue storage of 512 images taken at 4.5 MHz in the detector front end. The LPD detector has 500 mm thick silicon sensor tiles that are bump bonded to a readout ASIC. The ASICs preamplifier provides relatively low noise at high speed which results in a high dynamic range of 10^5 photons over an energy range of 5-20 keV. Small scale prototypes of 32x256 pixels (LPD 2-Tile detector) and 256x256 pixels (LPD supermodule detector) are now available for X-ray tests. The performance of prototypes of the detector is reported for first tests under synchrotron radiation (PETRA III at DESY) and Free-Electron-Laser radiation (LCLS at SLAC). The initial performance of the detector in terms of signal range and noise, radiation hardness and spatial and temporal response are reported. The main result is that the 4.5 MHz sampling detection chain is reliably working, including the analogue on-chip memory concept. The detector is at least radiation hard up to 5 MGy at 12 keV. In addition the multiple gain concept has been demonstrated over a dynamic range to 10^4 at 12 keV with a readout noise equivalent to <1 photon rms in its most sensitive mode.

preprint2013arXiv

Status of detector development for the European XFEL

The European X-ray Free Electron Laser (XFEL.EU) will provide as-yet-unrivaled peak brilliance and ultra-short pulses of spatially coherent X-rays with a pulse length of less than 100 fs in the energy range between 0.25 and 25 keV. The high radiation intensity and ultra-short pulse duration will open a window for novel scientific techniques and will allow to explore new phenomena in biology, chemistry, material science, as well as matter at high energy density, atomic, ion and molecular physics. The variety of scientific applications and especially the unique XFEL.EU time structure require adequate instrumentation to be developed in order to exploit the full potential of the light source. To make optimal use of the unprecedented capabilities of the European XFEL and master these vast technological challenges, the European XFEL GmbH has started a detector R&D program. The technology concepts of the detector system presently under development are complementary in their performance and will cover the requirements of a large fraction of the scientific applications envisaged for the XFEL.EU facility. The actual status of the detector development projects which includes ultra-fast 2D imaging detectors, low repetition rate 2D detectors as well as strip detectors for e.g. spectroscopy applications and the infrastructure for the detectors' calibration and tests will be presented. Furthermore, an overview of the forthcoming implementation phase of the European XFEL in terms of detector R&D will be given.

preprint2012arXiv

Detector Development for the European XFEL: Requirements and Status

The variety of applications and especially the unique European XFEL time structure will require adequate instrumentation to be developed to exploit the full potential of the light source. Two-dimensional integrating X-ray detectors with ultra-fast read out up to 4.5 MHz for 1024 x 1024 pixel images are under development for a variety of imaging applications. The actual status of the European XFEL detector development projects is presented. Furthermore, an outlook will be given with respect to detector research and development, performance optimization, integration, and commissioning.

preprint2012arXiv

Investigation of X-ray induced radiation damage at the Si-SiO2 interface of silicon sensors for the European XFEL

Experiments at the European X-ray Free Electron Laser (XFEL) require silicon pixel sensors which can withstand X-ray doses up to 1 GGy. For the investigation of X-ray radiation damage up to these high doses, MOS capacitors and gate-controlled diodes built on high resistivity n-doped silicon with crystal orientations <100> and <111> produced by two vendors, CiS and Hamamatsu, have been irradiated with 12 keV X-rays at the DESY DORIS III synchrotron light source. Using capacitance/conductance-voltage, current-voltage and thermal dielectric relaxation current measurements, the surface densities of oxide charges and interface traps at the Si-SiO2 interface, and the surface-current densities have been determined as function of dose. Results indicate that the dose dependence of the surface density of oxide charges and the surface-current density depend on the crystal orientation and producer. In addition, the influence of the voltage applied to the gates of the MOS capacitor and the gate-controlled diode during X-ray irradiation on the surface density of oxide charges and the surface-current density has been investigated at doses of 100 kGy and 100 MGy. It is found that both strongly depend on the gate voltage if the electric field in the oxide points from the surface of the SiO2 to the Si-SiO2 interface. Finally, annealing studies have been performed at 60 and 80 degree C on MOS capacitors and gate-controlled diodes irradiated to 5 MGy and the annealing kinetics of oxide charges and surface current determined.