Source author record

Georg Weidenspointner

Georg Weidenspointner appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

14works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

14 published item(s)

preprint2014arXiv

Geant4 and beyond: recent progress in precision physics modeling

This extended abstract briefly summarizes ongoing research activity on the evaluation and experimental validation of physics methods for photon and electron transport. The analysis includes physics models currently implemented in Geant4 as well as modeling methods used in other Monte Carlo codes, or not yet considered in general purpose Monte Carlo simulation systems. The validation of simulation models is performed with the support of rigorous statistical methods, which involve goodness-of-fit tests followed by categorical analysis. All results are quantitative, and are fully documented.

preprint2014arXiv

Multiwavelength observations of the black hole transient Swift J1745-26 during the outburst decay

We characterized the broad-band X-ray spectra of Swift J1745-26 during the decay of the 2013 outburst using INTEGRAL ISGRI, JEM-X and Swift XRT. The X-ray evolution is compared to the evolution in optical and radio. We fit the X- ray spectra with phenomenological and Comptonization models. We discuss possible scenarios for the physical origin of a ~50 day flare observed both in optical and X- rays ~170 days after the peak of the outburst. We conclude that it is a result of enhanced mass accretion in response to an earlier heating event. We characterized the evolution in the hard X-ray band and showed that for the joint ISGRI-XRT fits, the e-folding energy decreased from 350 keV to 130 keV, while the energy where the exponential cut-off starts increased from 75 keV to 112 keV as the decay progressed.We investigated the claim that high energy cut-offs disappear with the compact jet turning on during outburst decays, and showed that spectra taken with HEXTE on RXTE provide insufficient quality to characterize cut-offs during the decay for typical hard X-ray fluxes. Long INTEGRAL monitoring observations are required to understand the relation between the compact jet formation and hard X-ray behavior. We found that for the entire decay (including the flare), the X-ray spectra are consistent with thermal Comptonization, but a jet synchrotron origin cannot be ruled out.

preprint2014arXiv

Toward atomic resolution diffractive imaging of isolated molecules with x-ray free-electron lasers

We give a detailed account of the theoretical analysis and the experimental results of an x-ray-diffraction experiment on quantum-state selected and strongly laser-aligned gas-phase ensembles of the prototypical large asymmetric rotor molecule 2,5-diiodobenzonitrile, performed at the Linac Coherent Light Source [Phys. Rev. Lett. 112, 083002 (2014)]. This experiment is the first step toward coherent diffractive imaging of structures and structural dynamics of isolated molecules at atomic resolution, i. e., picometers and femtoseconds, using x-ray free-electron lasers.

preprint2014arXiv

Validation of Compton Scattering Monte Carlo Simulation Models

Several models for the Monte Carlo simulation of Compton scattering on electrons are quantitatively evaluated with respect to a large collection of experimental data retrieved from the literature. Some of these models are currently implemented in general purpose Monte Carlo systems; some have been implemented and evaluated for possible use in Monte Carlo particle transport for the first time in this study. Here we present first and preliminary results concerning total and differential Compton scattering cross sections.

preprint2014arXiv

X-ray diffraction from isolated and strongly aligned gas-phase molecules with a free-electron laser

We report experimental results on x-ray diffraction of quantum-state-selected and strongly aligned ensembles of the prototypical asymmetric rotor molecule 2,5-diiodobenzonitrile using the Linac Coherent Light Source. The experiments demonstrate first steps toward a new approach to diffractive imaging of distinct structures of individual, isolated gas-phase molecules. We confirm several key ingredients of single molecule diffraction experiments: the abilities to detect and count individual scattered x-ray photons in single shot diffraction data, to deliver state-selected, e. g., structural-isomer-selected, ensembles of molecules to the x-ray interaction volume, and to strongly align the scattering molecules. Our approach, using ultrashort x-ray pulses, is suitable to study ultrafast dynamics of isolated molecules.

preprint2013arXiv

Negative Improvements, Relative Validity and Elusive Goodness

Various issues related to the complexity of apprais- ing the capabilities of physics models implemented in Monte Carlo simulation codes and the evolution of the functional quality the associated software are considered, such as the dependence on the experimental environment where the software operates and its sensitivity to detector characteristics. The concept of software validity as relative to the environment is illustrated by means of a real-life experimental test case. Methods and techniques to mitigate the risk of deteriorating the quality of the software are critically discussed: they concern various disciplines of the software development process. Quantitative validation of physics models is advocated as a method to appraise their capabilities objectively and to monitor the evolution of their associated software behavior.

preprint2013arXiv

Radioactive Decays in Geant4

The simulation of radioactive decays is a common task in Monte-Carlo systems such as Geant4. Usually, a system either uses an approach focusing on the simulations of every individual decay or an approach which simulates a large number of decays with a focus on correct overall statistics. The radioactive decay package presented in this work permits, for the first time, the use of both methods within the same simulation framework - Geant4. The accuracy of the statistical approach in our new package, RDM-extended, and that of the existing Geant4 per-decay implementation (original RDM), which has also been refactored, are verified against the ENSDF database. The new verified package is beneficial for a wide range of experimental scenarios, as it enables researchers to choose the most appropriate approach for their Geant4-based application.

preprint2013arXiv

Validation of Geant4 simulation of electron energy deposition

Geant4-based simulations of the energy deposited by electrons in various materials are quantitatively compared to high precision calorimetric measurements taken at Sandia Laboratories. The experimental data concern electron beams of energy between a few tens of keV and 1 MeV at various incidence angles. Two experimental scenarios are evaluated: the longitudinal energy deposition pattern in a finely segmented detector, and the total energy deposited in a larger size calorimeter. The simulations are produced with Geant4 versions from 9.1 to 9.6; they involve models of electron-photon interactions in the standard and low energy electromagnetic packages, and various implementations of electron multiple scattering. Significant differences in compatibility with experimental data are observed in the longitudinal energy deposition patterns produced by the examined Geant4 versions, while the total deposited energy exhibits smaller variations across the various Geant4 versions, with the exception Geant4 9.4. The validation analysis, based on statistical methods, shows that the best compatibility between simulation and experimental energy deposition profiles is achieved using electromagnetic models based on the EEDL and EPDL evaluated data libraries with Geant4 9.1. The results document the accuracy achievable in the simulation of the energy deposited by low energy electrons with Geant4; they provide guidance for application in similar experimental scenarios and for improving Geant4.

preprint2013arXiv

Validation of Geant4-based Radioactive Decay Simulation

Radioactive decays are of concern in a wide variety of applications using Monte-Carlo simulations. In order to properly estimate the quality of such simulations, knowledge of the accuracy of the decay simulation is required. We present a validation of the original Geant4 Radioactive Decay Module, which uses a per-decay sampling approach, and of an extended package for Geant4-based simulation of radioactive decays, which, in addition to being able to use a refactored per-decay sampling, is capable of using a statistical sampling approach. The validation is based on measurements of calibration isotope sources using a high purity Germanium (HPGe) detector; no calibration of the simulation is performed. For the considered validation experiment equivalent simulation accuracy can be achieved with per-decay and statistical sampling.

preprint2012arXiv

Monte Carlo Simulation for Particle Detectors

Monte Carlo simulation is an essential component of experimental particle physics in all the phases of its life-cycle: the investigation of the physics reach of detector concepts, the design of facilities and detectors, the development and optimization of data reconstruction software, the data analysis for the production of physics results. This note briefly outlines some research topics related to Monte Carlo simulation, that are relevant to future experimental perspectives in particle physics. The focus is on physics aspects: conceptual progress beyond current particle transport schemes, the incorporation of materials science knowledge relevant to novel detection technologies, functionality to model radiation damage, the capability for multi-scale simulation, quantitative validation and uncertainty quantification to determine the predictive power of simulation. The R&D on simulation for future detectors would profit from cooperation within various components of the particle physics community, and synergy with other experimental domain sharing similar simulation requirements.

preprint2010arXiv

Conceptual challenges and computational progress in X-ray simulation

Recent developments and validation tests related to the simulation of X-ray fluorescence and PIXE with Geant4 are reviewed. They concern new models for PIXE, which has enabled the first Geant4-based simulation of PIXE in a concrete experimental application, and the experimental validation of the content of the EADL data library relevant to the simulation of X-ray fluorescence. Achievements and open issues in this domain are discussed.

preprint2010arXiv

New techniques in Monte Carlo simulation: experience with a prototype of generic programming application to Geant4 physics processes

An investigation is in progress to evaluate extensively and quantitatively the possible benefits and drawbacks of new programming paradigms in a Monte Carlo simulation environment, namely in the domain of physics modeling. The prototype design and extensive benchmarks, including a variety of rigorous quantitative metrics, are presented. The results of this research project allow the evaluation of new software techniques for their possible adoption in Monte Carlo simulation on objective, quantitative ground.

preprint2006arXiv

Radioactive 26Al and massive stars in the Galaxy

Gamma-rays from radioactive 26Al (half life ~7.2 10^5 yr) provide a 'snapshot' view of ongoing nucleosynthesis in the Galaxy. The Galaxy is relatively transparent to such gamma-rays, and emission has been found concentrated along the plane of the Galaxy. This led to the conclusion1 that massive stars throughout the Galaxy dominate the production of 26Al. On the other hand, meteoritic data show locally-produced 26Al, perhaps from spallation reactions in the protosolar disk. Furthermore, prominent gamma-ray emission from the Cygnus region suggests that a substantial fraction of Galactic 26Al could originate in localized star-forming regions. Here we report high spectral resolution measurements of 26Al emission at 1808.65 keV, which demonstrate that the 26Al source regions corotate with the Galaxy, supporting its Galaxy-wide origin. We determine a present-day equilibrium mass of 2.8 (+/-0.8) M_sol of 26Al. We use this to estimate that the frequency of core collapse (i.e. type Ib/c and type II) supernovae to be 1.9(+/- 1.1) events per century.