Researcher profile

Mario S Rodrigues

Mario S Rodrigues contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2013arXiv

Imaging material properties of biological samples with a Force Feedback Microscope

Mechanical properties of biological samples have been imaged with a \textit{Force Feedback Microscope}. Force, force gradient and dissipation are measured simultaneously and quantitatively, merely knowing the AFM cantilever spring constant. Our first results demonstrate that this robust method provides quantitative high resolution force measurements of the interaction The little oscillation imposed to the cantilever and the small value of its stiffness result in a vibrational energy much smaller than the thermal energy, reducing the interaction with the sample to a minimum. We show that the observed mechanical properties of the sample depend on the force applied by the tip and consequently on the sample indentation. Moreover, the frequency of the excitation imposed to the cantilever can be chosen arbitrarily, opening the way to frequency-dependent studies in biomechanics, sort of spectroscopic AFM investigations.

preprint2013arXiv

System analysis of Force Feedback Microscopy

It was shown recently that the Force Feedback Microscope can avoid the jump-to-contact in Atomic force Microscopy even when the cantilevers used are very soft, thus increasing force resolution. In this letter, we explore theoretical aspects of the associated real time control of the tip position. We take into account lever parameters such as the lever characteristics in its environment, spring constant, mass, dissipation coefficient and the operating conditions such as controller gains, and interaction force. We show how the controller parameters are determined so that the FFM functions at its best and estimate the bandwidth of the system under these conditions.