Source author record

Mario S Rodrigues

Mario S Rodrigues appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2014arXiv

Small amplitude Dynamic AFM: quantifying interactions with different tip detection and excitation schemes in presence of additional resonances

Quantifying the tip-sample interaction at the nanoscale in Amplitude Modulation mode AFM is challenging, especially when measuring in liquids. Here, we derive formulas for the tip-sample conservative and dissipative interactions and investigate the effect that spurious resonances have on the measured interaction. Both direct and acoustic excitation are considered. We also highlight the differences between measuring directly the tip position or the cantilever deflection. We show that, when probing the tip-sample forces, the acoustically excited cantilever behavior is insensitive to spurious resonances as long as the measured signal corresponds to the tip position, or if the excitation force is correctly taken into account. Since the effective excitation force may depend on the presence of such spurious resonances, we consider the cases where the frequency is kept constant during the measurement so that the proportionality between excitation signal and actual excitation force is kept constant. With the present work we show the advantages that result from the use of a calibration method based on the acquisition of approach-retract curves. Optical beam deflection based AFMs benefit from the use of this calibration method, especially in presence of spurious resonances in the cantilever transfer function.

preprint2013arXiv

Imaging material properties of biological samples with a Force Feedback Microscope

Mechanical properties of biological samples have been imaged with a \textit{Force Feedback Microscope}. Force, force gradient and dissipation are measured simultaneously and quantitatively, merely knowing the AFM cantilever spring constant. Our first results demonstrate that this robust method provides quantitative high resolution force measurements of the interaction The little oscillation imposed to the cantilever and the small value of its stiffness result in a vibrational energy much smaller than the thermal energy, reducing the interaction with the sample to a minimum. We show that the observed mechanical properties of the sample depend on the force applied by the tip and consequently on the sample indentation. Moreover, the frequency of the excitation imposed to the cantilever can be chosen arbitrarily, opening the way to frequency-dependent studies in biomechanics, sort of spectroscopic AFM investigations.

preprint2013arXiv

System analysis of Force Feedback Microscopy

It was shown recently that the Force Feedback Microscope can avoid the jump-to-contact in Atomic force Microscopy even when the cantilevers used are very soft, thus increasing force resolution. In this letter, we explore theoretical aspects of the associated real time control of the tip position. We take into account lever parameters such as the lever characteristics in its environment, spring constant, mass, dissipation coefficient and the operating conditions such as controller gains, and interaction force. We show how the controller parameters are determined so that the FFM functions at its best and estimate the bandwidth of the system under these conditions.