Source author record

Fabio Comin

Fabio Comin appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2013arXiv

Comparison between Atomic Force Microscopy and Force Feedback Microscopy static force curves

Atomic Force Microscopy (AFM) conventional static force curves and Force Feedback Microscopy (FFM) force curves acquired with the same cantilever at the solid/air and solid/liquid interfaces are here compared. The capability of the FFM to avoid the jump to contact leads to the complete and direct measurement of the interaction force curve, including the attractive short-range van der Waals and chemical contributions. Attractive force gradients five times higher than the lever stiffness do not affect the stability of the FFM static feedback loop. The feedback loop keeps the total force acting on the AFM tip equal to zero, allowing the use of soft cantilevers as force transducers to increase the instrumental sensitivity. The attractive interactions due to the nucleation of a capillary bridge at the native oxide silicon/air interface or due to a DLVO interaction at the mica/deionized water interface have been measured. This set up, suitable for measuring directly and quantitatively interfacial forces, can be exported to a SFA (Surface Force Apparatus).

preprint2013arXiv

Imaging material properties of biological samples with a Force Feedback Microscope

Mechanical properties of biological samples have been imaged with a \textit{Force Feedback Microscope}. Force, force gradient and dissipation are measured simultaneously and quantitatively, merely knowing the AFM cantilever spring constant. Our first results demonstrate that this robust method provides quantitative high resolution force measurements of the interaction The little oscillation imposed to the cantilever and the small value of its stiffness result in a vibrational energy much smaller than the thermal energy, reducing the interaction with the sample to a minimum. We show that the observed mechanical properties of the sample depend on the force applied by the tip and consequently on the sample indentation. Moreover, the frequency of the excitation imposed to the cantilever can be chosen arbitrarily, opening the way to frequency-dependent studies in biomechanics, sort of spectroscopic AFM investigations.

preprint2013arXiv

Spectroscopic investigation of local mechanical impedance of living cells

The mechanical properties of PC12 living cells have been studied at the nanoscale with a Force Feedback Microscope using two experimental approaches. Firstly, the local mechanical impedance of the cell membrane has been mapped simultaneously to the cell morphology at constant force. As the force of the interaction is gradually increased, we observed the appearance of the sub-membrane cytoskeleton. We shall compare the results obtained with this method with the measurement of other existing techniques. Secondly, a spectroscopic investigation has been performed varying the indentation of the tip in the cell membrane and consequently the force applied on it. In contrast with conventional dynamic atomic force microscopy techniques, here the small oscillation amplitude of the tip is not necessarily imposed at the cantilever first eigenmode. This allows the user to arbitrarily choose the excitation frequency in developing spectroscopic AFM techniques. The mechanical response of the PC12 cell membrane is found to be frequency dependent in the 1 kHz - 10 kHz range. The damping coefficient is reproducibly observed to decrease when the excitation frequency is increased.

preprint2013arXiv

System analysis of Force Feedback Microscopy

It was shown recently that the Force Feedback Microscope can avoid the jump-to-contact in Atomic force Microscopy even when the cantilevers used are very soft, thus increasing force resolution. In this letter, we explore theoretical aspects of the associated real time control of the tip position. We take into account lever parameters such as the lever characteristics in its environment, spring constant, mass, dissipation coefficient and the operating conditions such as controller gains, and interaction force. We show how the controller parameters are determined so that the FFM functions at its best and estimate the bandwidth of the system under these conditions.

preprint2012arXiv

Measurement of the complete interaction force curve at the nanoscale

The force between two interacting particles as a function of distance is one of the most fundamental curves in science. In this regard, Atomic Force Microscopy (AFM) represents the most powerful tool in nanoscience but with severe limits when it is to probe attractive interactions with high sensitivity. The Force Feedback Microscope (FFM) described here, removes from AFM the well known jump to contact problem that precludes the complete exploration of the interaction curve and the study of associated energy exchanges. The FFM makes it possible to explore tip-surface interactions in the entire range of distances with a sensitivity better than 1 pN. FFM stands out as a radical change in AFM control paradigms. With a surprisingly simple arrangement it is possible to provide the AFM tip with the right counterforce to keep it fixed at any time. The counterforce is consequently equal to the tip-sample force. The force, force gradient and damping are simultaneously measured independently of the tip position. This permits the measurement of energy transfer in thermodynamic transformations. Here we show some FFM measurement examples of the complete interaction force curve and in particular that the FFM can follow the nucleation of a water bridge by measuring the capillary attractive force at all distances, without jump to contact despite the large attractive capillary force. Real time combination of the measured parameters will lead to new imaging modalities with chemical contrast in different environments.

preprint2010arXiv

Can nanotechnology experimentally solve the plane-plane challenge

Non-contact interaction between two parallel flat surfaces is a central paradigm in sciences. This situation is the starting point for a wealth of different models: the capacitor description in electrostatics, hydrodynamic flow, thermal exchange, the Casimir force, direct contact study, third body confinement such as liquids or films of soft condensed matter. The control of parallelism is so demanding that no versatile single force machine in this geometry has been proposed so far. Using a combination of nanopositioning based on inertial motors and microcrystal shaping with Focused Ion Beams (FIB) we propose here an experimental set up that should enable one to measure interactions between movable surfaces separated by gaps in the micrometer and the nanometer ranges.