Source author record

Marco Cortesi

Marco Cortesi appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2022arXiv

Snowmass 2021 Instrumentation Frontier (IF5 - MPGDs) -- White Paper 2: Micro Pattern Gaseous Detectors for Nuclear Physics

Many current and future nuclear physics (NP) experiments across the United States have and are implementing micro-pattern gas detectors (MPGDs) to be used for tracking and PID purposes. MPGDs are capable of operating in high rate environments and providing excellent spatial resolution over a large-area with a low material budget. Summarized in this white paper is the role that MPGDs are playing in NP experiments and the R&D which is needed to meet the requirements of future NP experiments.

preprint2015arXiv

Operation of a THGEM-based detector in low-pressure Helium

In view of a possible application as a charge-particle track readout for an Active Target Time Projection Chamber (AT-TPC), the operating properties of THick Gaseous Electron Multipliers (THGEM) in pure low-pressure Helium were investigated. This paper includes the effective gain dependence on pressure for different detector configurations (single-, double-, triple-cascade setup), long-term gain stability and energy resolution from tracks of 5.5 MeV alpha particles. Stable operational conditions and maximum detector gains of 10^4-10^7 have been achieved in pure Helium at pressure ranging from 100 torr up to 760 torr. Energy resolution of 6.65% (FWHM) for 690 keV of energy deposited by 5.5 MeV alpha particles at 350 torr was measured. The expected energy resolution for the full track is around 2.4% (FWHM). These results, together with the robustness of THGEM electrodes against spark damage, make THGEM structures highly competitive compared to other technologies considered for TPC applications in an active target operating with pure noble gases, requiring a high dynamic range and a wide operating pressure range down to few hundred torr.

preprint2015arXiv

Studies of THGEM-based detector at low-pressure Hydrogen/Deuterium, for AT-TPC applications

We study the performance of single- and double- THick Gas Electron Multiplier (THGEM) detectors in pure Hydrogen and Deuterium at low pressures, in the range of 100-450 Torr. The effect of the pressure on the maximum achievable gain, ion-back flow and long-term gain stability are investigated for single and double cascade detectors. In particular, it was found that maximum achievable gains above 10^4, from single-photoelectrons avalanche, can be achieved for pressures of 200 Torr and above; for lower pressure the gains are limited by avalanche-induced secondary effects to a values of around 103. The results of this work are relevant in the field of avalanche mechanism in low-pressure, low-mass noble gases, in particular for applications of THGEM end-cap readout for active-target Time Projection Chambers (TPC) in the field of nuclear physics and nuclear astrophysics.

preprint2011arXiv

Hybrid Multi Micropattern Gaseous Photomultiplier for detection of liquid-xenon scintillation

Gaseous PhotoMultipliers (GPM) are a very promising alternative of vacuum PMTs especially for large-size noble-liquid detectors in the field of Functional Nuclear Medical Imaging and Direct Dark Matter Detection. We present recent characterization results of a Hybrid-GPM made of three Micropattern Gaseous Structures; a Thick Gaseous Electron Multiplier (THGEM), a Parallel Ionization Multiplier (PIM) and a MICROMesh GAseous Structure (MICROMEGAS),operating in Ne/CF4 (90:10). Gain values close to 10^7 were recorded in this mixture, with 5.9keV x-rays at 1100 mbar, both at room temperature and at that of liquid xenon (T = 171K). The results are discussed in term of scintillation detection. While the present multiplier was investigated without photocathode, complementary results of photoextraction from CsI UV photocathodes are presented in Ne/CH4 (95:5) and CH4 in cryogenic conditions.

preprint2010arXiv

A UV Sensitive Integrated Micromegas with Timepix Readout

This article presents a detector system consisting of three components, a CMOS imaging array, a gaseous-detector structure with a Micromegas layout and a UV-photon sensitive CsI reflective photocathode. All three elements have been monolithically integrated using simple post-processing steps. The Micromegas structure and the CMOS imaging chip are not impacted by the CsI deposition. The detector operated reliably in He/isobutane mixtures and attained charge gains with single photons up to a level of 6 \cdot 10^4. The Timepix CMOS array permitted high resolution imaging of single UV-photons. The system has an MTF50 of 0.4 lp/pixel which corresponds to app. 7 lp/mm.