Source author record

Amos Breskin

Amos Breskin appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

8works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2019arXiv

First demonstration of a bubble-assisted Liquid Hole Multiplier operation in liquid argon

We demonstrate, for the time, the operation of a bubble-assisted Liquid Hole Multiplier (LHM) in liquid argon. The LHM, sensitive to both radiation-induced ionization electrons and primary scintillation photons, consists of a perforated electrode immersed in the noble liquid, with a stable gas-bubble trapped underneath. Electrons deposited in the liquid or scintillation-induced photoelectrons emitted from a photocathode on the electrode's surface, are collected into the holes; after crossing the liquid-gas interface, they induce electroluminescence within the bubble. After having validated in previous works the LHM concept in liquid xenon, we provide here first preliminary results on its operation in liquid argon. We demonstrate the bubble containment under a Thick Gas Electron Multiplier (THGEM) electrode and provide detector response to alpha particles, recorded with a SiPM - under electroluminescence and with modest gas multiplication; the imaging capability is also demonstrated.

preprint2013arXiv

Beam Studies of the Segmented Resistive WELL: a Potential Thin Sampling Element for Digital Hadron Calorimetry

Thick Gas Electron Multipliers (THGEMs) have the potential of constituting thin, robust sampling elements in Digital Hadron Calorimetry (DHCAL) in future colliders. We report on recent beam studies of new single- and double-THGEM-like structures; the multiplier is a Segmented Resistive WELL (SRWELL) - a single-faced THGEM in contact with a segmented resistive layer inductively coupled to readout pads. Several 10$\times$10 cm$^2$ configurations with a total thickness of 5-6 mm (excluding electronics) with 1 cm$^2$ pads coupled to APV-SRS readout were investigated with muons and pions. Detection efficiencies in the 98$%$ range were recorded with average pad-multiplicity of $\sim$1.1. The resistive anode resulted in efficient discharge damping, with potential drops of a few volts; discharge probabilities were $\sim10^{-7}$ for muons and $\sim10^{-6}$ for pions in the double-stage configuration, at rates of a few kHz/cm$^2$. Further optimization work and research on larger detectors are underway.

preprint2013arXiv

Liquid Hole-Multipliers: A potential concept for large single-phase noble-liquid TPCs of rare events

A novel concept is proposed for large-volume single-phase noble-liquid TPC detectors for rare events. Both radiation-induced scintillation-light and ionization-charge are detected by Liquid Hole-Multipliers, LHM, immersed in the noble liquid. The latter may consist of cascaded Gas Electron Multipliers (GEM), Thick Gas Electron Multiplier (THGEM) electrodes or others, coated with CsI UV-photocathodes. Electrons, photo-induced on CsI by primary scintillation in the noble liquid, and event-correlated drifting ionization electrons are amplified in the cascaded elements primarily through electroluminescence, and possibly through additional moderate avalanche, occurring within the holes. The resulting charge-signals or light-pulses are recorded on anode pads or with photosensors, e.g. gaseous photomultipliers (GPM), respectively. Potential affordable solutions are proposed for multi-ton dark-matter detectors; open questions are formulated for validating this dream.

preprint2011arXiv

Hybrid Multi Micropattern Gaseous Photomultiplier for detection of liquid-xenon scintillation

Gaseous PhotoMultipliers (GPM) are a very promising alternative of vacuum PMTs especially for large-size noble-liquid detectors in the field of Functional Nuclear Medical Imaging and Direct Dark Matter Detection. We present recent characterization results of a Hybrid-GPM made of three Micropattern Gaseous Structures; a Thick Gaseous Electron Multiplier (THGEM), a Parallel Ionization Multiplier (PIM) and a MICROMesh GAseous Structure (MICROMEGAS),operating in Ne/CF4 (90:10). Gain values close to 10^7 were recorded in this mixture, with 5.9keV x-rays at 1100 mbar, both at room temperature and at that of liquid xenon (T = 171K). The results are discussed in term of scintillation detection. While the present multiplier was investigated without photocathode, complementary results of photoextraction from CsI UV photocathodes are presented in Ne/CH4 (95:5) and CH4 in cryogenic conditions.

preprint2010arXiv

A UV Sensitive Integrated Micromegas with Timepix Readout

This article presents a detector system consisting of three components, a CMOS imaging array, a gaseous-detector structure with a Micromegas layout and a UV-photon sensitive CsI reflective photocathode. All three elements have been monolithically integrated using simple post-processing steps. The Micromegas structure and the CMOS imaging chip are not impacted by the CsI deposition. The detector operated reliably in He/isobutane mixtures and attained charge gains with single photons up to a level of 6 \cdot 10^4. The Timepix CMOS array permitted high resolution imaging of single UV-photons. The system has an MTF50 of 0.4 lp/pixel which corresponds to app. 7 lp/mm.

preprint2010arXiv

An integrated Micromegas UV-photon detector

Preliminary results of a photon detector combining a Micromegas like multiplier coated with a UV-sensitive CsI photocathode are described. The multiplier is made in a CMOS compatible InGrid technology, which allows to post-process it directly on the surface of an imaging IC. This method is aimed at building light-sensitive imaging detectors where all elements are monolithically integrated. We show that the CsI photocathode deposited in the InGrid mesh does not alter the device performance. Maximum gains of ~6000 were reached in a single-grid element operated in Ar/CH4, with a 2% Ion Back Flow fraction returning to the photocathode.

preprint2006arXiv

Mapping the Sensitive Volume of an Ion-Counting Nanodosimeter

We present two methods of independently mapping the dimensions of the sensitive volume in an ion-counting nanodosimeter. The first method is based on a calculational approach simulating the extraction of ions from the sensitive volume, and the second method on probing the sensitive volume with 250 MeV protons. Sensitive-volume maps obtained with both methods are compared and systematic errors inherent in both methods are quantified.