Test of \textit{Topmetal-${II}^-$} In Liquid Nitrogen For Cryogenic Temperature TPCs
\textit{Topmetal-${II}^-$} is a highly pixelated direct charge sensor that contains a 72${\times}$72 pixel array of 83$μ$m pitch size. The key feature of \textit{Topmetal-${II}^-$} is that it can directly collect charges via metal nodes of each pixel to form two-dimensional images of charge cloud distributions. \textit{Topmetal-${II}^-$} was proved to measure charged particles without amplification at room temperature. To measure its performance at cryogenic temperature, a \textit{Topmetal-${II}^-$} sensor is embedded into a liquid nitrogen dewar. The results presented in this paper show that \textit{Topmetal-${II}^-$} can also operate well at this low temperature with a noise (ENC) of 12 e$^-$ lower than that at room temperature (13 e$^-$). From the noise perspective, \textit{Topmetal-${II}^-$} is a promising candidate for the next generation readout of liquid argon and xenon Time Projection Chamber (TPC) used in experiments searching for neutrinoless double beta decay and dark matter.