Researcher profile

M. Tytgat

M. Tytgat contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
12works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

12 published item(s)

preprint2022arXiv

Quality Control of Mass-Produced GEM Detectors for the CMS GE1/1 Muon Upgrade

The series of upgrades to the Large Hadron Collider, culminating in the High Luminosity Large Hadron Collider, will enable a significant expansion of the physics program of the CMS experiment. However, the accelerator upgrades will also make the experimental conditions more challenging, with implications for detector operations, triggering, and data analysis. The luminosity of the proton-proton collisions is expected to exceed $2-3\times10^{34}$~cm$^{-2}$s$^{-1}$ for Run 3 (starting in 2022), and it will be at least $5\times10^{34}$~cm$^{-2}$s$^{-1}$ when the High Luminosity Large Hadron Collider is completed for Run 4. These conditions will affect muon triggering, identification, and measurement, which are critical capabilities of the experiment. To address these challenges, additional muon detectors are being installed in the CMS endcaps, based on Gas Electron Multiplier technology. For this purpose, 161 large triple-Gas Electron Multiplier detectors have been constructed and tested. Installation of these devices began in 2019 with the GE1/1 station and will be followed by two additional stations, GE2/1 and ME0, to be installed in 2023 and 2026, respectively. The assembly and quality control of the GE1/1 detectors were distributed across several production sites around the world. We motivate and discuss the quality control procedures that were developed to standardize the performance of the detectors, and we present the final results of the production. Out of 161 detectors produced, 156 detectors passed all tests, and 144 detectors are now installed in the CMS experiment. The various visual inspections, gas tightness tests, intrinsic noise rate characterizations, and effective gas gain and response uniformity tests allowed the project to achieve this high success rate.

preprint2022arXiv

Simulation Studies of a Novel Muography Detector for the Great Pyramids

Muography is an imaging technique that can be used to examine the interior structure of large-size objects. The technique is based on measurements of the absorption of cosmic-ray muons passing through the object under study. Muographic imaging was already successfully applied to the discovery of a new void inside the Great Pyramid of Khufu at Giza, Egypt. With the aim of studying the Pyramid of Khafre, the second largest pyramid at Giza, a new muography detector is currently being constructed. In this paper we report on the development of a corresponding new simulation framework of the Great Pyramids and the detector setup. This simulation will serve as a basis to develop the data and image reconstruction algorithms to be used during our future muography campaign in the Pyramid of Khafre, and will allow us to study the relevant experimental conditions at the site.

preprint2022arXiv

The MURAVES experiment: study of the Vesuvius Great Cone with Muon Radiography

The MURAVES experiment aims at the muographic imaging of the internal structure of the summit of Mt. Vesuvius, exploiting muons produced by cosmic rays. Though presently quiescent, the volcano carries a dramatic hazard in its highly populated surroundings. The challenging measurement of the rock density distribution in its summit by muography, in conjunction with data from other geophysical techniques, can help the modeling of possible eruptive dynamics. The MURAVES apparatus consists of an array of three independent and identical muon trackers, with a total sensitive area of 3 square meters. In each tracker, a sequence of 4 XY tracking planes made of plastic scintillators is complemented by a 60 cm thick lead wall inserted between the two downstream planes to improve rejection of background from low energy muons. The apparatus is currently acquiring data. Preliminary results from the analysis of a first data sample are presented.

preprint2022arXiv

The simulations chain of the MURAVES experiment

The MUon RAdiography of VESuvius (MURAVES) project aims at the study of the summital cone of Mt. Vesuvius, an active and hazardous volcano near Naples, Italy. A detailed Monte Carlo simulation framework is necessary in order to investigate the effects of the experimental constraints and to perform comparisons with the actual observations. Our Monte Carlo setup combines a variety of Monte Carlo programs that address different aspects of cosmic muon simulation, from muon generation in the Earth's upper atmosphere to the response of the detector, including the interactions with the material of the volcano. We will elaborate on the rationale for our technical choices, including trade-off between speed and accuracy, and on the lessons learned, which are of general interest for similar use cases in muon radiography.

preprint2022arXiv

Towards a portable high-resolution muon detector based on Resistive Plate Chambers

The use of conventional imaging techniques becomes problematic when faced with challenging logistics and confined environments. In particular, such scenarios are not unusual in the field of archaeological and mining explorations as well as for nuclear waste characterization. For these applications, even the use of muography is complicated since the detectors have to be deployed in difficult areas with limited room for instrumentation, e.g., narrow tunnels. To address this limitation, we have developed a portable muon detector (muoscope) based on glass Resistive Plate Chambers (RPC) with an active area of 16 $\times$ 16 cm$^{2}$. The specific design goals taken into consideration while developing our first prototype are portability, robustness, autonomy, versatility, safety and low cost. To help further improve our design goals, we are currently studying the possibility to switch the sensitive units from strips in the old prototype to pixels for the new one However, for performing high resolution muography, the number of readout units per layer will also need to increase significantly, leading to increase in the overall cost and power consumption of the muoscope. To mitigate these issues, we are developing a novel 2D multiplexing algorithm for reading out several pixels with a single electronic channel. In this article, we give an overview of the detector development, focusing mainly on the design goals and the choice of detector technology. Furthermore, we present the details of the expected changes in the new prototype as well as a simulated 2D multiplexing study based on general principles.

preprint2021arXiv

A portable muon telescope for multidisciplinary applications

Muon tomography or muography is an emerging imaging technique that uses cosmogenic muons as the radiation source. Due to its diverse range of applications and the use of natural radiation, muography is being applied across many fields such as geology, archaeology, civil engineering, nuclear reactor monitoring, nuclear waste characterization, underground surveys, etc. Muons can be detected using various detector technologies, among which, resistive plate chambers (RPC) are a very cost effective choice. RPCs are planar detectors which use ionization in a thin gas gap to detect cosmic muons, already used since years in major particle accelerator experiments. We have developed a muon telescope (or muoscope) composed of small scale RPCs. The design goal for our muoscope is to be portable and autonomous, in order to take data in places that are not easily accessible. The whole setup is light and compact, such to be easily packed in a car trunk. Individual RPCs are hosted in gas-tight aluminium cases. There is no need for gas bottles, once the chambers are filled. The muoscope can be controlled from a reasonable distance using wireless connection. In this paper, we summarize the guiding principles of our project and present some recent developments and future prospects, including a long-term stability study of the resistivity of the semiconductive coating obtained with serigraphy.

preprint2021arXiv

End-to-end simulations of the MUon RAdiography of VESuvius experiment

The MUon RAdiography of VESuvius (MURAVES) project aims at the study of the summital cone of Mt. Vesuvius, an active volcano near Naples (Italy), by measuring its density profile through muon flux attenuation. Its data, combined with those from gravimetric and seismic measurement campaigns, will be used for better defining the volcanic plug at the bottom of the crater. We report on the development of an end-to-end simulation framework, in order to perform accurate investigations of the effects of the experimental constraints and to compare simulations, under various model hypotheses, with the actual observations. The detector simulation setup is developed using GEANT4 and a study of cosmic particle generators has been conducted to identify the most suitable one for our simulation framework. To mimic the real data, GEANT4 raw hits are converted to clusters through a simulated digitization: energy deposits are first summed per scintillator bar, and then converted to number of photoelectrons with a data-driven procedure. This is followed by the same clustering algorithm and same tracking code as in real data. We also report on the study of muon transport through rock using PUMAS and GEANT4. In this paper we elaborate on the rationale for our technical choices, including trade-off between speed and accuracy. The developments reported here are of general interest in muon radiography and can be applied in similar cases.

preprint2021arXiv

Modeling the triple-GEM detector response to background particles for the CMS Experiment

An estimate of environmental background hit rate on triple-GEM chambers is performed using Monte Carlo (MC) simulation and compared to data taken by test chambers installed in the CMS experiment (GE1/1) during Run-2 at the Large Hadron Collider (LHC). The hit rate is measured using data collected with proton-proton collisions at 13 TeV and a luminosity of 1.5$\times10^{34}$ cm$^{-2}$ s$^{-1}$. The simulation framework uses a combination of the FLUKA and Geant4 packages to obtain the hit rate. FLUKA provides the radiation environment around the GE1/1 chambers, which is comprised of the particle flux with momentum direction and energy spectra ranging from $10^{-11}$ to $10^{4}$ MeV for neutrons, $10^{-3}$ to $10^{4}$ MeV for $γ$'s, $10^{-2}$ to $10^{4}$ MeV for $e^{\pm}$, and $10^{-1}$ to $10^{4}$ MeV for charged hadrons. Geant4 provides an estimate of detector response (sensitivity) based on an accurate description of detector geometry, material composition and interaction of particles with the various detector layers. The MC simulated hit rate is estimated as a function of the perpendicular distance from the beam line and agrees with data within the assigned uncertainties of 10-14.5%. This simulation framework can be used to obtain a reliable estimate of background rates expected at the High Luminosity LHC.

preprint2021arXiv

Upgrade of the CMS Resistive Plate Chambers for the High Luminosity LHC

During the upcoming High Luminosity phase of the Large Hadron Collider (HL-LHC), the integrated luminosity of the accelerator will increase to 3000 fb$^{-1}$. The expected experimental conditions in that period in terms of background rates, event pileup, and the probable aging of the current detectors present a challenge for all the existing experiments at the LHC, including the Compact Muon Solenoid (CMS) experiment. To ensure a highly performing muon system for this period, several upgrades of the Resistive Plate Chamber (RPC) system of the CMS are currently being implemented. These include the replacement of the readout system for the present system, and the installation of two new RPC stations with improved chamber and front-end electronics designs. The current overall status of this CMS RPC upgrade project is presented.

preprint2020arXiv

Azimuthal single- and double-spin asymmetries in semi-inclusive deep-inelastic lepton scattering by transversely polarized protons

A comprehensive set of azimuthal single-spin and double-spin asymmetries in semi-inclusive leptoproduction of pions, charged kaons, protons, and antiprotons from transversely polarized protons is presented. These asymmetries include the previously published HERMES results on Collins and Sivers asymmetries, the analysis of which has been extended to include protons and antiprotons and also to an extraction in a three-dimensional kinematic binning and enlarged phase space. They are complemented by corresponding results for the remaining four single-spin and four double-spin asymmetries allowed in the one-photon-exchange approximation of the semi-inclusive deep-inelastic scattering process for target-polarization orientation perpendicular to the direction of the incoming lepton beam. Among those results, significant non-vanishing $\cos{ϕ-ϕ_S}$ modulations provide evidence for a sizable worm-gear (II) distribution, $g_{1T}$. Most of the other modulations are found to be consistent with zero with the notable exception of large $\sin{ϕ_S}$ modulations for charged pions and positive kaons.

preprint2020arXiv

Interstrip Capacitances of the Readout Board used in Large Triple-GEM Detectors for the CMS Muon Upgrade

We present analytical calculations, Finite Element Analysis modeling, and physical measurements of the interstrip capacitances for different potential strip geometries and dimensions of the readout boards for the GE2/1 triple-Gas Electron Multiplier detector in the CMS muon system upgrade. The main goal of the study is to find configurations that minimize the interstrip capacitances and consequently maximize the signal-to-noise ratio for the detector. We find agreement at the 1.5--4.8% level between the two methods of calculations and on the average at the 17% level between calculations and measurements. A configuration with halved strip lengths and doubled strip widths results in a measured 27--29% reduction over the original configuration while leaving the total number of strips unchanged. We have now adopted this design modification for all eight module types of the GE2/1 detector and will produce the final detector with this new strip design.

preprint2018arXiv

High Rate RPC detector for LHC

The High Luminosity LHC (HL-LHC) phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. The foreseen gradual increase of the instantaneous luminosity of up to more than twice its nominal value of $10\times10^{34}\ {\rm cm}^{-1}{\rm s}^{-2}$ during Phase I and Phase II of the LHC running, presents special challenges for the experiments. The region with high pseudo rapidity ($η$) region of the forward muon spectrometer ($2.4 > |η| > 1.9$) is not equipped with RPC stations. The increase of the expected particles rate up to 2 kHz cm$^{-1}$ ( including a safety factor 3 ) motivates the installation of RPC chambers to guarantee redundancy with the CSC chambers already present. The current CMS RPC technology cannot sustain the expected background level. A new generation of Glass-RPC (GRPC) using low-resistivity glass was proposed to equip the two most far away of the four high $η$ muon stations of CMS. In their single-gap version they can stand rates of few kHz cm$^{-1}$. Their time precision of about 1 ns can allow to reduce the noise contribution leading to an improvement of the trigger rate. The proposed design for large size chambers is examined and some preliminary results obtained during beam tests at Gamma Irradiation Facility (GIF++) and Super Proton Synchrotron (SPS) at CERN are shown. They were performed to validate the capability of such detectors to support high irradiation environment with limited consequence on their efficiency.