Source author record

M. Kitaguchi

M. Kitaguchi appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

11works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

11 published item(s)

preprint2022arXiv

Angular distribution of $γ$ rays from the p-wave resonance of $^{118}$Sn

The neutron energy-dependent angular distribution of $γ$ rays from $^{117}{\rm Sn}(n,γ)$ reaction was measured with germanium detectors and a pulsed neutron beam. The angular distribution was clearly observed in $γ$-ray emissions with an energy of 9327 keV which corresponds to the transition from a neutron resonance of $^{117}{\rm Sn}+n$ to the ground state of $^{118}{\rm Sn}$. The angular distribution causes an angular-dependent asymmetric resonance shape. An asymmetry $A_{\rm LH}$ was defined as $(N_{\rm L}-N_{\rm H})/(N_{\rm L}+N_{\rm H})$, where $N_{\rm L}$ and $N_{\rm H}$ are integrated values for lower- and higher-energy regions of a neutron resonance, respectively. We found that the $A_{\rm LH}$ has the angular dependence of $(A \cos θ_γ+B)$, where $θ_γ$ is the $γ$-ray emission angle with respect to the incident neutron momentum, with $A=0.394 \pm 0.073$ and $B = 0.118 \pm 0.029$ in the 1.33 eV p-wave resonance.

preprint2020arXiv

Development and application of a $^3$He Neutron Spin Filter at J-PARC

We are developing a neutron polarizer with polarized $^3$He gas, referred to as a $^3$He spin filter, based on the Spin Exchange Optical Pumping (SEOP) for polarized neutron scattering experiments at Materials and Life Science Experimental Facility (MLF) of Japan Proton Accelerator Research Complex (J-PARC). A $^3$He gas-filling station was constructed at J-PARC, and several $^3$He cells with long spin relaxation times have been fabricated using the gas-filling station. A laboratory has been prepared in the MLF beam hall for polarizing $^3$He cells, and compact pumping systems with laser powers of 30~W and 110~W, which can be installed onto a neutron beamline, have been developed. A $^3$He polarization of 85% was achieved at a neutron beamline by using the pumping system with the 110~W laser. Recently, the first user experiment utilizing the $^3$He spin filter was conducted, and there have been several more since then. The development and utilization of $^3$He spin filters at MLF of J-PARC are reported.

preprint2020arXiv

Neutron lifetime measurement with pulsed cold neutrons

The neutron lifetime has been measured by comparing the decay rate with the reaction rate of $^3$He nuclei of a pulsed neutron beam from the spallation neutron source at the Japan Proton Accelerator Research Complex (J-PARC). The decay rate and the reaction rate were determined by simultaneously detecting electrons from the neutron decay and protons from the $^3$He(n,p)$^3$H reaction using a gas chamber of which working gas contains diluted $^3$He. The measured neutron lifetime was $898\,\pm\,10\,_{\rm stat}\,^{+15}_{-18}\,_{\rm sys}\,$s.

preprint2016arXiv

A neutron detector with spatial resolution of submicron using fine-grained nuclear emulsion

We have been developing a neutron detector with spatial resolution of submicron by loading 6Li into fine-grained nuclear emulsion. By exposure to thermal neutrons, tracks from neutron capture events were observed. From their grain density, spatial resolution was estimated. Detection efficiency was also measured by an experiment with cold neutrons.

preprint2015arXiv

Development of time projection chamber for precise neutron lifetime measurement using pulsed cold neutron beams

A new time projection chamber (TPC) was developed for neutron lifetime measurement using a pulsed cold neutron spallation source at the Japan Proton Accelerator Research Complex (J-PARC). Managing considerable background events from natural sources and the beam radioactivity is a challenging aspect of this measurement. To overcome this problem, the developed TPC has unprecedented features such as the use of polyether-ether-ketone plates in the support structure and internal surfaces covered with $^6$Li-enriched tiles to absorb outlier neutrons. In this paper, the design and performance of the new TPC are reported in detail.

preprint2015arXiv

Pulsed UCN production using a Doppler shifter at J-PARC

We have constructed a Doppler-shifter-type pulsed ultra-cold neutron (UCN) source at the Materials and Life Science Experiment Facility (MLF) of the Japan Proton Accelerator Research Complex (J-PARC). Very-cold neutrons (VCNs) with 136-$\mathrm{m/s}$ velocity in a neutron beam supplied by a pulsed neutron source are decelerated by reflection on a m=10 wide-band multilayer mirror, yielding pulsed UCN. The mirror is fixed to the tip of a 2,000-rpm rotating arm moving with 68-$\mathrm{m/s}$ velocity in the same direction as the VCN. The repetition frequency of the pulsed UCN is $8.33~\mathrm{Hz}$ and the time width of the pulse at production is $4.4~\mathrm{ms}$. In order to increase the UCN flux, a supermirror guide, wide-band monochromatic mirrors, focus guides, and a UCN extraction guide have been newly installed or improved. The $1~\mathrm{MW}$-equivalent count rate of the output neutrons with longitudinal wavelengths longer than $58~\mathrm{nm}$ is $1.6 \times 10^{2}~\mathrm{cps}$, while that of the true UCNs is $80~\mathrm{cps}$. The spatial density at production is $1.4~\mathrm{UCN/cm^{3}}$. This new UCN source enables us to research and develop apparatuses necessary for the investigation of the neutron electric dipole moment (nEDM).

preprint2014arXiv

Observation of the Spatial Distribution of Gravitationally Bound Quantum States of Ultracold Neutrons and Its Derivation Using the Wigner Function

Ultracold neutrons (UCNs) can be bound by the potential of terrestrial gravity and a reflecting mirror. The wave function of the bound state has characteristic modulations. We carried out an experiment to observe the vertical distribution of the UCNs above such a mirror at Institut Laue-Langevin in 2011. The observed modulation is in good agreement with that prediction by quantum mechanics using the Wigner function. The spatial resolution of the detector system is estimated to be 0.7 micro meter. This is the first observation of gravitationally bound states of UCNs with submicron spatial resolution.

preprint2010arXiv

Development of a Pixel Detector for Ultra-Cold Neutrons

A pixel detector with high spatial resolution and temporal information for ultra-cold neutrons is developed based on a commercial CCD on which a neutron converter is attached. 10B and 6Li are tested for the neutron converter and 10B is found to be more suitable based on efficiency and spatial resolution. The pixel detector has an efficiency of 44.1 +- 1.1% and a spatial resolution of 2.9 +- 0.1 um (1 sigma).