Source author record

M. Hino

M. Hino appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2020arXiv

Development and application of a $^3$He Neutron Spin Filter at J-PARC

We are developing a neutron polarizer with polarized $^3$He gas, referred to as a $^3$He spin filter, based on the Spin Exchange Optical Pumping (SEOP) for polarized neutron scattering experiments at Materials and Life Science Experimental Facility (MLF) of Japan Proton Accelerator Research Complex (J-PARC). A $^3$He gas-filling station was constructed at J-PARC, and several $^3$He cells with long spin relaxation times have been fabricated using the gas-filling station. A laboratory has been prepared in the MLF beam hall for polarizing $^3$He cells, and compact pumping systems with laser powers of 30~W and 110~W, which can be installed onto a neutron beamline, have been developed. A $^3$He polarization of 85% was achieved at a neutron beamline by using the pumping system with the 110~W laser. Recently, the first user experiment utilizing the $^3$He spin filter was conducted, and there have been several more since then. The development and utilization of $^3$He spin filters at MLF of J-PARC are reported.

preprint2019arXiv

Final results for the neutron $β$-asymmetry parameter $A_0$ from the UCNA experiment

The UCNA experiment was designed to measure the neutron $β$-asymmetry parameter $A_0$ using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the spectrometer. A value for $A_0$ was then extracted from the asymmetry in the numbers of counts in the two detector packages. We summarize all of the results from the UCNA experiment, obtained during run periods in 2007, 2008--2009, 2010, and 2011--2013, which ultimately culminated in a 0.67\% precision result for $A_0$.

preprint2016arXiv

A neutron detector with spatial resolution of submicron using fine-grained nuclear emulsion

We have been developing a neutron detector with spatial resolution of submicron by loading 6Li into fine-grained nuclear emulsion. By exposure to thermal neutrons, tracks from neutron capture events were observed. From their grain density, spatial resolution was estimated. Detection efficiency was also measured by an experiment with cold neutrons.

preprint2015arXiv

Pulsed UCN production using a Doppler shifter at J-PARC

We have constructed a Doppler-shifter-type pulsed ultra-cold neutron (UCN) source at the Materials and Life Science Experiment Facility (MLF) of the Japan Proton Accelerator Research Complex (J-PARC). Very-cold neutrons (VCNs) with 136-$\mathrm{m/s}$ velocity in a neutron beam supplied by a pulsed neutron source are decelerated by reflection on a m=10 wide-band multilayer mirror, yielding pulsed UCN. The mirror is fixed to the tip of a 2,000-rpm rotating arm moving with 68-$\mathrm{m/s}$ velocity in the same direction as the VCN. The repetition frequency of the pulsed UCN is $8.33~\mathrm{Hz}$ and the time width of the pulse at production is $4.4~\mathrm{ms}$. In order to increase the UCN flux, a supermirror guide, wide-band monochromatic mirrors, focus guides, and a UCN extraction guide have been newly installed or improved. The $1~\mathrm{MW}$-equivalent count rate of the output neutrons with longitudinal wavelengths longer than $58~\mathrm{nm}$ is $1.6 \times 10^{2}~\mathrm{cps}$, while that of the true UCNs is $80~\mathrm{cps}$. The spatial density at production is $1.4~\mathrm{UCN/cm^{3}}$. This new UCN source enables us to research and develop apparatuses necessary for the investigation of the neutron electric dipole moment (nEDM).

preprint2014arXiv

Observation of the Spatial Distribution of Gravitationally Bound Quantum States of Ultracold Neutrons and Its Derivation Using the Wigner Function

Ultracold neutrons (UCNs) can be bound by the potential of terrestrial gravity and a reflecting mirror. The wave function of the bound state has characteristic modulations. We carried out an experiment to observe the vertical distribution of the UCNs above such a mirror at Institut Laue-Langevin in 2011. The observed modulation is in good agreement with that prediction by quantum mechanics using the Wigner function. The spatial resolution of the detector system is estimated to be 0.7 micro meter. This is the first observation of gravitationally bound states of UCNs with submicron spatial resolution.

preprint2010arXiv

Development of a Pixel Detector for Ultra-Cold Neutrons

A pixel detector with high spatial resolution and temporal information for ultra-cold neutrons is developed based on a commercial CCD on which a neutron converter is attached. 10B and 6Li are tested for the neutron converter and 10B is found to be more suitable based on efficiency and spatial resolution. The pixel detector has an efficiency of 44.1 +- 1.1% and a spatial resolution of 2.9 +- 0.1 um (1 sigma).