Researcher profile

M. Fallot

M. Fallot contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
7works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2026arXiv

Study of $\boldsymbolβ$ Decay Shape Factors in First-Forbidden Transitions with $\boldsymbol{ΔI^π= 0^-}$ for Reactor Antineutrino Spectra Predictions

The electron spectra of the $β$ decays of $^{92}$Rb and $^{142}$Cs, key contributors to the reactor antineutrino spectrum, were measured at the IGISOL facility using radioactive beams of high isotopic purity. The shapes of the measured $β$ spectra were compared with various $β$ shape models, including first-forbidden correction factors for $ΔI^π= 0^-$ ground-state to ground-state transitions. Comparisons with previous experimental results are also provided. The shapes of the newly measured $β$ spectra are well reproduced employing feedings extracted from total absorption gamma spectroscopy measurements.

preprint2022arXiv

The Double Chooz antineutrino detectors

This article describes the setup and performance of the near and far detectors in the Double Chooz experiment. The electron antineutrinos of the Chooz nuclear power plant were measured in two identically designed detectors with different average baselines of about 400 m and 1050 m from the two reactor cores. Over many years of data taking the neutrino signals were extracted from interactions in the detectors with the goal of measuring a fundamental parameter in the context of neutrino oscillation, the mixing angle θ13. The central part of the Double Chooz detectors was a main detector comprising four cylindrical volumes filled with organic liquids. From the inside towards the outside there were volumes containing gadolinium-loaded scintillator, gadolinium-free scintillator, a buffer oil and, optically separated, another liquid scintillator acting as veto system. Above this main detector an additional outer veto system using plastic scintillator strips was installed. The technologies developed in Double Chooz were inspiration for several other antineutrino detectors in the field. The detector design allowed implementation of efficient background rejection techniques including use of pulse shape information provided by the data acquisition system. The Double Chooz detectors featured remarkable stability, in particular for the detected photons, as well as high radiopurity of the detector components.

preprint2022arXiv

Total absorption $γ$-ray spectroscopy of the $β$ decays of $^{96\text{gs,m}}$Y

The $β$ decays of the ground state (gs) and isomeric state (m) of $^{96}$Y have been studied with the total absorption $γ$-ray spectroscopy technique at the Ion Guide Isotope Separator On-Line facility. The separation of the 8$^{+}$ isomeric state from the 0$^{-}$ ground state was achieved thanks to the purification capabilities of the JYFLTRAP double Penning trap system. The $β$-intensity distributions of both decays have been independently determined. In the analyses the de-excitation of the 1581.6 keV level in $^{96}$Zr, in which conversion electron emission competes with pair production, has been carefully considered and found to have significant impact on the $β$-detector efficiency, influencing the $β$-intensity distribution obtained. Our results for $^{96\text{gs}}$Y (0$^+$) confirm the large ground state to ground state $β$-intensity probability, although a slightly larger value than reported in previous studies was obtained, amounting to $96.6_{-2.1}^{+0.3}\%$ of the total $β$ intensity. Given that the decay of $^{96\text{gs}}$Y is the second most important contributor to the reactor antineutrino spectrum between 5 and 7 MeV, the impact of the present results on reactor antineutrino summation calculations has been evaluated. In the decay of $^{96\text{m}}$Y (8$^{+}$), previously undetected $β$ intensity in transitions to states above 6 MeV has been observed. This shows the importance of total absorption $γ$-ray spectroscopy measurements of $β$ decays with highly fragmented de-excitation patterns. $^{96\text{m}}$Y (8$^{+}$) is a major contributor to reactor decay heat in uranium-plutonium and thorium-uranium fuels around 10 s after fission pulses, and the newly measured average $β$ and $γ$ energies differ significantly from the previous values in evaluated databases (...)

preprint2021arXiv

Development of a Reference Database for Beta-Delayed Neutron Emission

Beta-delayed neutron emission is important for nuclear structure and astrophysics as well as for reactor applications. Significant advances in nuclear experimental techniques in the past two decades have led to a wealth of new measurements that remain to be incorporated in the databases. We report on a coordinated effort to compile and evaluate all the available beta-delayed neutron emission data. The different measurement techniques have been assessed and the data have been compared with semi-microscopic and microscopic-macroscopic models. The new microscopic database has been tested against aggregate total delayed neutron yields, time-dependent group parameters in 6-and 8-group re-presentation, and aggregate delayed neutron spectra. New recommendations of macroscopic delayed-neutron data for fissile materials of interest to applications are also presented. The new Reference Database for Beta-Delayed Neutron Emission Data is available online at: http://www-nds.iaea.org/beta-delayed-neutron/database.html.

preprint2020arXiv

Determination of Beta Decay Ground State Feeding of Nuclei of Importance for Reactor Applications

In $β$-decay studies the determination of the decay probability to the ground state of the daughter nucleus often suffers from large systematic errors. The difficulty of the measurement is related to the absence of associated delayed $γ$-ray emission. In this work we revisit the $4πγ-β$ method proposed by Greenwood and collaborators in the 1990s, which has the potential to overcome some of the experimental difficulties. Our interest is driven by the need to determine accurately the $β$-intensity distributions of fission products that contribute significantly to the reactor decay heat and to the antineutrinos emitted by reactors. A number of such decays have large ground state branches. The method is relevant for nuclear structure studies as well. Pertinent formulae are revised and extended to the special case of $β$-delayed neutron emitters, and the robustness of the method is demonstrated with synthetic data. We apply it to a number of measured decays that serve as test cases and discuss the features of the method. Finally, we obtain ground state feeding intensities with reduced uncertainty for four relevant decays that will allow future improvements in antineutrino spectrum and decay heat calculations using the summation method.

preprint2019arXiv

Commissioning and Operation of the Readout System for the SoLid Neutrino Detector

The SoLid experiment aims to measure neutrino oscillation at a baseline of 6.4 m from the BR2 nuclear reactor in Belgium. Anti-neutrinos interact via inverse beta decay (IBD), resulting in a positron and neutron signal that are correlated in time and space. The detector operates in a surface building, with modest shielding, and relies on extremely efficient online rejection of backgrounds in order to identify these interactions. A novel detector design has been developed using 12800 5 cm cubes for high segmentation. Each cube is formed of a sandwich of two scintillators, PVT and 6LiF:ZnS(Ag), allowing the detection and identification of positrons and neutrons respectively. The active volume of the detector is an array of cubes measuring 80x80x250 cm (corresponding to a fiducial mass of 1.6 T), which is read out in layers using two dimensional arrays of wavelength shifting fibres and silicon photomultipliers, for a total of 3200 readout channels. Signals are recorded with 14 bit resolution, and at 40 MHz sampling frequency, for a total raw data rate of over 2 Tbit/s. In this paper, we describe a novel readout and trigger system built for the experiment, that satisfies requirements on: compactness, low power, high performance, and very low cost per channel. The system uses a combination of high price-performance FPGAs with a gigabit Ethernet based readout system, and its total power consumption is under 1 kW. The use of zero suppression techniques, combined with pulse shape discrimination trigger algorithms to detect neutrons, results in an online data reduction factor of around 10000. The neutron trigger is combined with a large per-channel history time buffer, allowing for unbiased positron detection. The system was commissioned in late 2017, with successful physics data taking established in early 2018.

preprint2014arXiv

Precision Muon Reconstruction in Double Chooz

We describe a muon track reconstruction algorithm for the reactor anti-neutrino experiment Double Chooz. The Double Chooz detector consists of two optically isolated volumes of liquid scintillator viewed by PMTs, and an Outer Veto above these made of crossed scintillator strips. Muons are reconstructed by their Outer Veto hit positions along with timing information from the other two detector volumes. All muons are fit under the hypothesis that they are through-going and ultrarelativistic. If the energy depositions suggest that the muon may have stopped, the reconstruction fits also for this hypothesis and chooses between the two via the relative goodness-of-fit. In the ideal case of a through-going muon intersecting the center of the detector, the resolution is ~40 mm in each transverse dimension. High quality muon reconstruction is an important tool for reducing the impact of the cosmogenic isotope background in Double Chooz.