Source author record

M. Blatnik

M. Blatnik appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2026arXiv

Detection of ultracold neutrons with powdered scintillator screens

Zinc sulfide (ZnS:Ag) scintillators coated with a thin 10B layer are widely used for ultracold neutron (UCN) detection, but their application is limited by long decay times and significant phosphorescence. We investigated two possible replacement scintillators: yttrium aluminum perovskite (YAP:Ce) and lutetium ttrium orthosilicate (LYSO:Ce). Both exhibit decay times on the order of 30-40 ns, which can help reduce dead time in high-count-rate experiments. YAP:Ce showed approximately 60% lower phosphorescence than ZnS:Ag after 2 days and detected about 20% more UCN. In contrast, LYSO:Ce exhibited higher phosphorescence and produced fewer UCN counts compared to both ZnS:Ag and YAP:Ce. While both tested scintillators are capable UCN detectors, YAP:Ce consistently outperformed LYSO:Ce across all measured performance metrics.

preprint2022arXiv

Fill and dump measurement of the neutron lifetime using an asymmetric magneto-gravitational trap

The past two decades have yielded several new measurements and reanalyses of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the lifetime measured in neutron storage experiments. Measurements using different techniques are important for investigating whether there are unidentified systematic effects in any of the measurements. In this paper we report a new measurement using the Los Alamos asymmetric magneto-gravitational trap where the surviving neutrons are counted external to the trap using the fill and dump method. The new measurement gives a free neutron lifetime of . Although this measurement is not as precise, it is in statistical agreement with previous results using in situ counting in the same apparatus.

preprint2019arXiv

Final results for the neutron $β$-asymmetry parameter $A_0$ from the UCNA experiment

The UCNA experiment was designed to measure the neutron $β$-asymmetry parameter $A_0$ using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the spectrometer. A value for $A_0$ was then extracted from the asymmetry in the numbers of counts in the two detector packages. We summarize all of the results from the UCNA experiment, obtained during run periods in 2007, 2008--2009, 2010, and 2011--2013, which ultimately culminated in a 0.67\% precision result for $A_0$.

preprint2019arXiv

Improved limits on Fierz Interference using asymmetry measurements from the UCNA experiment

The Ultracold Neutron Asymmetry (UCNA) experiment was designed to measure the $β$-decay asymmetry parameter, $A_0$, for free neutron decay. In the experiment, polarized ultracold neutrons are transported into a decay trap, and their $β$-decay electrons are detected with $\approx 4π$ acceptance into two detector packages which provide position and energy reconstruction. The experiment also has sensitivity to $b_{n}$, the Fierz interference term in the neutron $β$-decay rate. In this work, we determine $b_{n}$ from the energy dependence of $A_0$ using the data taken during the UCNA 2011-2013 run. In addition, we present the same type of analysis using the earlier 2010 $A$ dataset. Motivated by improved statistics and comparable systematic errors compared to the 2010 data-taking run, we present a new $b_{n}$ measurement using the weighted average of our asymmetry dataset fits, to obtain $b_{n} = 0.066 \pm 0.041_{\text{stat}} \pm 0.024_{\text{syst}}$ which corresponds to a limit of $-0.012 < b_{n} < 0.144$ at the 90% confidence level.

preprint2016arXiv

Performance of a Quintuple-GEM Based RICH Detector Prototype

Cerenkov technology is often the optimal choice for particle identification in high energy particle collision applications. Typically, the most challenging regime is at high pseudorapidity (forward) where particle identification must perform well at high high laboratory momenta. For the upcoming Electron Ion Collider (EIC), the physics goals require hadron ($π$, K, p) identification up to $\sim$~50 GeV/c. In this region Cerenkov Ring-Imaging is the most viable solution.\newline The speed of light in a radiator medium is inversely proportional to the refractive index. Hence, for PID reaching out to high momenta a small index of refraction is required. Unfortunately, the lowest indices of refraction also result in the lowest light yield ($\frac{dN_γ}{dx} \propto \sin^2{\left(θ_C \right)}$) driving up the radiator length and thereby the overall detector cost. In this paper we report on a successful test of a compact RICH detector (1 meter radiator) capable of delivering in excess of 10 photoelectrons per ring with a low index radiator gas ($CF_4$). The detector concept is a natural extension of the PHENIX HBD detector achieved by adding focusing capability at low wavelength and adequate gain for high efficiency detection of single-electron induced avalanches. Our results indicate that this technology is indeed a viable choice in the forward direction of the EIC. The setup and results are described within.