Researcher profile

Luc Beaulieu

Luc Beaulieu contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
6works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2022arXiv

External beam irradiation angle measurement using Cerenkov emission

Due to its angular dependency, Cerenkov light has long been considered a contamination signal in plastic scintillating dosimeters. In this study, we propose a novel approach designed to take advantage of this angular dependency to perform a direct measurement of an external beam radiation angle of incidence. A Cerenkov probe composed of a 10-mm long filtered sensitive volume of clear PMMA optical fibre was built. Both filtered and raw Cerenkov signals from the transport fibre were collected through a single 1-mm diameter transport fibre. An independent PSD composed of 10-mm BCF12 scintillating fibre was also used for simultaneous dose measurements. A first series of measurements aimed at validating the ability to account for the Cerenkov electron energy spectrum dependency by simultaneously measuring the deposited dose. A cylindrical phantom was then used to obtain an angular calibration curve for fixed dose irradiations and perform incident angle measurements using electron and photon beams. The beam nominal energy was found to have a significant impact on the shapes of the angular calibration curves obtained for irradiation angle measurements. This can be linked to the electron energy spectrum dependency of the Cerenkov emission cone. Irradiation angle measurements exhibit an absolute mean error of 1.86° and 1.02° at 6 and 18 MV, respectively. Similar results were obtained with electron beams and the absolute mean error reaches 1.97, 1.66, 1.45 and 0.95 degrees at 9, 12, 16 and 20 MeV, respectively. Reducing the numerical aperture of the Cerenkov probe leads to an increased angular dependency for the lowest energy while no major changes were observed at higher energy. This allowed irradiation angle measurements at 6 MeV with a mean absolute error of 4.82°. The detector offers promising perspectives for external beam radiotherapy and brachytherapy applications.

preprint2022arXiv

External beam irradiation angle measurement using Cerenkov emission I: Signal dependencies consideration

This study introduces a novel hybrid Cerenkov-scintillation dosimeter which is intended to be used for irradiation angle measurements based on the Cerenkov angular dependency. First measurements aimed at validating the ability to account for the Cerenkov electron energy spectrum dependency by simultaneously measuring the deposited dose, thus isolating signal variations resulting from the angular dependency. The Cerenkov probe is composed of a 10-mm long sensitive volume of clear PMMA optical fiber separated by an absorptive filter from a 1-mm diameter transport fiber. Filtered and raw Cerenkov signals from the sensitive volume and transport fiber, respectively, were collected using the Hyperscint RP-200 scintillation dosimetry platform. The total signal was unmixed using a hyperspectral approach. Dose calibration of the detector signal was accomplished with photon and electron beams. Using a solid-water phantom, measurements at fixed incident angles covering a wide range of doses and output factors were realized. For fixed incident angle, signal characterization of the Cerenkov detector displays a linear dose-light relationship. As expected, the sensitive volume signal was found to be energy dependent. Output factors were accurately measured within 0.8 % for field size up to 25 cm x 25 cm with both photons and electrons. First validation of the Cerenkov angular dependency shows a linear dose-light relationship for the whole range of angles tested. As expected, the Cerenkov signal intensity per dose unit varies based on the irradiation angle due to the angular dependency. Results showed that using calibration conditions where the electron energy spectrum is similar to the measurement conditions allows to rely on deposited dose to account for this dependency. These preliminary results constitute a first step toward experimental irradiation angle measurements.

preprint2020arXiv

From conception to clinical trial: IViST -- the first multi-sensor-based platform for real-time In Vivo dosimetry and Source Tracking in HDR brachytherapy

This study aims to introduce IViST (In Vivo Source Tracking), a novel multi-sensors dosimetry platform for real-time treatment monitoring in HDR brachytherapy. IViST is a platform that comprises 3 parts: 1) an optimized and characterized multi-point plastic scintillator dosimeter (3 points mPSD; using BCF-60, BCF-12, and BCF-10 scintillators), 2) a compact assembly of photomultiplier tubes (PMTs) coupled to dichroic mirrors and filters for high-sensitivity scintillation light collection, and 3) a Python-based graphical user interface used for system management and signal processing. IViST can simultaneously measure dose, triangulate source position, and measure dwell time. By making 100 000 measurements/s, IViST samples enough data to quickly perform key QA/QC tasks such as identifying wrong individual dwell time or interchanged transfer tubes. By using 3 co-linear sensors and planned information for an implant geometry (from DICOM RT), the platform can also triangulate source position in real-time. A clinical trial is presently on-going using the IViST system.

preprint2020arXiv

Light-Generating CdSe/CdS Colloidal Quantum Dot-Doped Plastic Optical Fibers

Colloidal quantum dots (cQDs) are now a mature nanomaterial with optical properties customizable through varying size and composition. However, their use in optical devices is limited as they are not widely available in convenient forms such as optical fibers. With advances in polymerization methods incorporating nanocrystals, nanocomposite materials suitable for processing into high quality hybrid active fibers can be achieved. We demonstrate a plastic optical fiber fabrication method which ensures homogeneous dispersion of cQDs within a polymer core matrix. Loading concentrations between 10$^{11}$-10$^{13}$ CdSe/CdS cQDs per cm$^{3}$ in polystyrene were electronically imaged, confirming only sporadic sub-wavelength aggregates. Rayleigh scattering losses are therefore dominant at energies below the semiconductors' band gap, but are overtaken by a sharp CdS-related absorption onset around 525 nm facilitating cQD excitation. The redshifted photoluminescence emission is then minimally reabsorbed along the fiber with a spectrum barely affected by the polymerization and a quantum yield staying at $\sim$65$\%$ of its initial value. The latter, along with the glass transition temperature and refractive index, is independent of the cQD concentration hence yielding a proportionally increasing light output. Our cQD-doped fibers are photostable to within 5$\%$ over days showing great promise for functional material applications.

preprint2020arXiv

On the use of machine learning methods for mPSD calibration in HDR brachytherapy

Purpose: We sought to evaluate the feasibility of using machine learning algorithms for multipoint plastic scintillator detector calibration in high-dose-rate brachytherapy. Methods: The dosimetry system consisted of an optimized 1-mm-core mPSD and a compact assembly of photomultiplier tubes coupled with dichroic mirrors and filters. An $^{192}$Ir source was remotely controlled and sent to various positions in a homemade PMMA holder. Dose measurements covering a range of 0.5 to 12 cm of source displacement were carried out according to TG-43 recommendations. Individual scintillator doses were decoupled using a linear regression model, a random forest estimator, and artificial neural network algorithms. The performance of the different algorithms was evaluated using different sample sizes and distances to the source for the mPSD system calibration. Results: The decoupling methods' deviations from the expected TG-43 dose generally remained below 20%. However, the dose prediction with the three algorithms was accurate to within 7% relative to the dose predicted by the TG-43 formalism for measurements performed in the same range of distances used for calibration. The performance random forest was compromised when the predictions were done beyond the range of distances used for calibration. The dose prediction by the linear regression was less influenced by the calibration conditions than random forest, but with more significant deviations. The number of available measurements for training purposes influenced the random forest and neural network models the most. Their accuracy tended to converge toward deviation values close to 1% from a number of dwell positions greater than 100. Conclusions: In performing HDR brachytherapy dose measurements with an optimized mPSD system, ML algorithms are good alternatives for precise dose reporting and treatment assessment.

preprint2019arXiv

Dosimetric performance of a multi-point plastic scintillator dosimeter as a tool for real-time source tracking in high dose rate brachytherapy

Purpose: To present the performance of a multi-point plastic scintillation detector (mPSD) as a tool in vivo dosimetry in brachytherapy. Methods: A previously optimized three-point sensor system was used for in vivo HDR brachytherapy measurements (using the scintillators BCF-60, BCF-12, and BCF-10). The light detection system of the mPSD consisted of compactly assembled photomultiplier tubes (PMTs) and dichroic mirrors and filters to achieve a highly sensitive scintillation light collection. The PMT signals were recorded using a NI-DAQ board at a rate of 100 kHz. Dose measurements covering a range of 0.5 to 10 cm from the 192Ir source were carried out according to TG-43 U1 recommendations in order to: (1) characterize the system's response in terms of angular dependence; (2) obtain the relative contribution of positioning and measurement uncertainties to the total system uncertainty; (3) assess the system's temporal resolution; and (4) track the source position in real time. Results: The positioning uncertainty dominated close to the source, whereas the measurement uncertainty dominated at larger distances. A maximum measurement uncertainty of 17 % was observed for the BCF-60 scintillator at 10 cm from the source. The average best compromise between positioning and measurement uncertainties were reached at 17.4 mm. The detector further exhibited no angular dependence. The system provided an average location with a standard deviation under 1.7 mm. The maximum observed differences between measured and expected source location was 1.82 mm. Dose deviations remained below 5% in all the explored measurement conditions. With regard to dwell time measurement accuracy, the maximum deviation observed at all distances was 0.56 s. Conclusions: The performance of the system demonstrated that it could be used for real-time dose, position and dwell time measurements during HDR brachytherapy.