Source author record

Lora Nugent-Glandorf

Lora Nugent-Glandorf appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2014arXiv

Open-Air, Broad-Bandwidth Trace-Gas Sensing with a Mid-Infrared Optical Frequency Comb

A mid-Infrared frequency comb is produced via an optical parametric oscillator (OPO) pumped by an amplified 100 MHz Yb:fiber mode-locked laser. We use this source to make measurements of the concentration of the atmospherically-relevant species of CH4 and H2O over a bandwidth of 100 nm centered at 3.25 um. Multiple absorption lines for each species are detected with millisecond acquisition time using a virtually-imaged phased array (VIPA) spectrometer. The measured wavelength-dependent absorption profile is compared to and fitted by a model, yielding quantitative values of the atmospheric concentration of both CH4 and H2O in a controlled indoor environment, as well as over a 26 m open air outdoor path.

preprint2012arXiv

Mid-infrared VIPA Spectrometer for Rapid and Broadband Trace Gas Detection

We present and characterize a 2-D imaging spectrometer based on a virtually-imaged phased array (VIPA) disperser for rapid, high-resolution molecular detection using mid-infrared (MIR) frequency combs at 3.1 and 3.8 μm. We demonstrate detection of CH4 at 3.1 μm with >3750 resolution elements spanning >80 nm with ~600 MHz resolution in a <10 μs acquisition time. In addition to broadband detection, rapid, time-resolved single-image detection is demonstrated by capturing dynamic concentration changes of CH4 at a rate of ~375 frames per second. Changes in absorption above the noise floor of 5\times 10-4 are readily detected on the millisecond time scale, leading to important future applications such as real time monitoring of trace gas concentrations and detection of reactive intermediates.

preprint2011arXiv

The Impact of Dispersion on Amplitude and Frequency Noise in a Yb-fiber Laser Comb

We describe a Yb-fiber based laser comb, with a focus on the relationship between net-cavity dispersion and the frequency noise on the comb. While tuning the net cavity dispersion from anomalous to normal, we measure the amplitude noise (RIN), offset frequency (f_CEO) linewidth, and the resulting frequency noise spectrum on f_CEO. We find that the laser operating at zero net-cavity dispersion has many advantages, including an approximately 100x reduction in free-running f_CEO linewidth and frequency noise power spectral density between laser operation at normal and zero dispersion. In this latter regime, we demonstrate a phase-locked f_CEO beat with low residual noise.