Source author record

Lev V. Levitin

Lev V. Levitin appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2023arXiv

Microstructuring YbRh2Si2 for resistance and noise measurements down to ultra-low temperatures

The discovery of superconductivity in the quantum critical Kondo-lattice system YbRh2Si2 at an extremely low temperature of 2 mK has inspired efforts to perform high-resolution electrical resistivity measurements down to this temperature range in highly conductive materials. Here we show that control over the sample geometry by microstructuring using focused-ion-beam (FIB) techniques allows to reach ultra-low temperatures and increase signal-to-noise ratios (SNR) tenfold, without adverse effects to sample quality. In five experiments we show four-terminal sensing resistance and magnetoresistance measurements which exhibit sharp phase transitions at the Néel temperature, and Shubnikov-de-Haas (SdH) oscillations between 13 T and 18 T where we identified a new SdH frequency of 0.39 kT. The increased SNR allowed resistance fluctuation (noise) spectroscopy that would not be possible for bulk crystals, and confirmed intrinsic 1/f-type fluctuations. Under controlled strain, two thin microstructured samples exhibited a large increase of T_N from 67 mK up to 188 mK while still showing clear signatures of the phase transition and SdH oscillations. SQUID-based thermal noise spectroscopy measurements in a nuclear demagnetisation refrigerator down to 0.95 mK, show a sharp superconducting transition at T_c = 1.2 mK. These experiments demonstrate microstructuring as a powerful tool to investigate the resistance and the noise spectrum of highly conductive correlated metals over wide temperature ranges.

preprint2022arXiv

Cooling low-dimensional electron systems into the microkelvin regime

Two-dimensional electron gases (2DEGs) with high mobility, engineered in semiconductor heterostructures host a variety of ordered phases arising from strong correlations, which emerge at sufficiently low temperatures. The 2DEG can be further controlled by surface gates to create quasi-one dimensional systems, with potential spintronic applications. Here we address the long-standing challenge of cooling such electrons to below 1$\,$mK, potentially important for identification of topological phases and spin correlated states. The 2DEG device was immersed in liquid $^3$He, cooled by the nuclear adiabatic demagnetization of copper. The temperature of the 2D electrons was inferred from the electronic noise in a gold wire, connected to the 2DEG by a metallic ohmic contact. With effective screening and filtering, we demonstrate a temperature of 0.9$\,\pm\,$0.1$\,$mK, with scope for significant further improvement. This platform is a key technological step, paving the way to observing new quantum phenomena, and developing new generations of nanoelectronic devices exploiting correlated electron states.

preprint2013arXiv

Current Sensing Noise Thermometry: A fast practical solution to low temperature measurement

We describe the design and performance of a series of fast, precise current sensing noise thermometers. The thermometers have been fabricated with a range of resistances from 1.290 $Ω$ down to 0.2 m$\mathrmΩ$. This results in either a thermometer that has been optimised for speed, taking advantage of the improvements in superconducting quantum interference device (SQUID) noise and bandwidth, or a thermometer optimised for ultra-low temperature measurement, minimising the system noise temperature. By using a single temperature calibration point, we show that noise thermometers can be used for accurate measurements over a wide range of temperatures below 4 K. Comparisons with a melting curve thermometer, a calibrated germanium thermometer and a pulsed platinum nuclear magnetic resonance thermometer are presented. For the 1.290 $\mathrmΩ$ resistance we measure a 1 % precision in just 100 ms, and have shown this to be independent of temperature.