Researcher profile

Koichi Ichimura

Koichi Ichimura contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - UnverifiedVerification L1Unclaimed author
5works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2021arXiv

Direction-sensitive dark matter search with a low-background gaseous detector NEWAGE-0.3b''

NEWAGE is a direction-sensitive dark matter search using a low-pressure gaseous time projection chamber. A low alpha-ray emission rate micro pixel chamber had been developed in order to reduce background for dark matter search. We conducted the dark matter search at the Kamioka Observatory in 2018. The total live time was 107.6 days corresponding to an exposure of 1.1 kg${\cdot}$days. Two events remained in the energy region of 50-60 keV which was consistent with 2.5 events of the expected background. A directional analysis was carried out and no significant forward-backward asymmetry derived from the WIMP-nucleus elastic scatterings was found. Thus a 90% confidence level upper limit on Spin-Dependent WIMP-proton cross section of 50 pb for a WIMP mass of 100 GeV/c2 was derived. This limit is the most stringent yet obtained from direction-sensitive dark matter search experiments.

preprint2020arXiv

Anisotropic Response Measurements of ZnWO$_4$ Scintillators to Neutrons for Developing the Direction-Sensitive Dark Matter Detector

The scintillation yields of ZnWO$_4$ crystals change depending on the incident direction of particles. This property can be used as a direction-sensitive dark matter detector. So, we investigated the ZnWO$_4$ light yields ratio of neutron-induced nuclear recoils to gamma-ray induced electron recoils(quenching factor). Two surfaces almost perpendicular to the crystal axis of ZnWO$_4$ were irradiated with a quasi-monochromatic neutron beam of 0.885MeV, and the quenching factors of both surfaces for the oxygen-nucleus recoil in the ZnWO$_4$ crystal were measured. The obtained quenching factors of the two surfaces were 0.235 $\pm$ 0.026 and 0.199 $\pm$ 0.020, respectively confirming 15.3$\%$ of anisotropy.

preprint2020arXiv

Development of a low-$α$-emitting $μ$-PIC as a readout device for direction-sensitive dark matter detectors

Direction sensitivity could provide robust evidence for the direct detection of weakly interacting massive particles constituting dark matter. However, the sensitivity of this method remains low due to the radioactive backgrounds. The purpose of this study is to develop a low-background detector as a two-dimensional imaging device for a gaseous time projection chamber. In direction-sensitive dark matter experiments~(e.g. NEWAGE), $α$-rays emitted from the detector components often create substantial radioactive backgrounds. Based on the study of the background of NEWAGE, a new detector "low-$α$ $μ$-PIC" is developed. The produced $μ$-PIC performs well as a gas detector and the $α$-ray emission rate from the $μ$-PIC reduced by a factor of 100.

preprint2020arXiv

Development of Dual-phase Xenon TPC with a Quartz Chamber for Direct Dark Matter Search

The idea of a hermetic quartz chamber in a dual-phase xenon time projection chamber (TPC) has the potential to improve the detector sensitivity for direct dark matter searches in the future. A major challenge facing TPC detectors in future dark matter experiments will be the reduction of the internal background such as $^{222}$Rn and the deterioration of the ionization signal due to electronegative impurities. The hermetic quartz chamber can isolate the TPC's sensitive volume from external interference and is thus expected to prevent contamination caused by the radioactive and electronegative impurities, which originate from outer detector materials. At the Kamioka Observatory in Japan, we developed a TPC with a quartz chamber that contains a $ϕ48 \times 58$ mm volume of liquid xenon. At this development stage, we did not aim at the perfect hermeticity of the quartz chamber. Our aim here is twofold: first, to demonstrate via the use of a calibration source that the presence of quartz materials in the TPC does not impact its operation; and second, to perform quantitative measurements of the TPC's characteristics. We successfully measured electron drift velocities of 1.2--1.7 mm/$μ$s in liquid xenon under electric fields ranging from 75--384 V/cm, and also observed small S2 signals produced by a single ionized electron with a light yield of 16.5 $\pm$ 0.5 PE. These results were consistent with the expected values; therefore, our demonstrations provide a proof of principle for TPCs incorporating a quartz chamber.

preprint2019arXiv

High-light-yield calcium iodide (CaI2) scintillator for astroparticle physics

A high light yield calcium iodide (CaI2) scintillator is being developed for an astroparticle physics experiments. This paper reports scintillation performance of calcium iodide (CaI2) crystal. Large light emission of 2.7 times that of NaI(Tl) and an emission wavelength in good agreement with the sensitive wavelength of the photomultiplier were obtained. A study of pulse shape discrimination using alpha and gamma sources was also performed. We confirmed that CaI2 has excellent pulse shape discrimination potential with a quick analysis.