Source author record

Julia Scherschligt

Julia Scherschligt appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2024arXiv

On the effect of "glancing" collisions in the cold atom vacuum standard

We theoretically investigate the effect of ``glancing" collisions on the ultra-high vacuum (UHV) pressure readings of the cold atom vacuum standard (CAVS), based on either ultracold $^7$Li or $^{87}$Rb atoms. Here, glancing collisions are those collisions between ultracold atoms and room-temperature background atoms or molecules in the vacuum that do not impart enough kinetic energy to eject an ultracold atom from its trap. Our model is wholly probabilistic and shows that the number of the ultracold atoms remaining in the trap as a function of time is non-exponential. We update the recent results of a comparison between a traditional pressure standard -- a combined flowmeter and dynamic expansion system -- to the CAVS [D.S. Barker, et al., arXiv:2302.12143] to reflect the results of our model. We find that the effect of glancing collisions shifts the theoretical predictions of the total loss rate coefficients for $^7$Li colliding with noble gases or N$_2$ by up to $0.6$ %. Likewise, we find that in the limit of zero trap depth the experimentally extracted loss rate coefficients for $^{87}$Rb colliding with noble gases or N$_2$ shift by as much as 2.2 %.

preprint2022arXiv

Comparison of two multiplexed portable cold-atom vacuum standards

We compare the vacuum measured by two portable cold-atom vacuum standards (pCAVS) based on ultracold $^7$Li atoms. The pCAVS are quantum-based standards that use a priori scattering calculations to convert a measured loss rate of cold atoms from a conservative trap into a background gas pressure. Our pCAVS devices share the same laser system and measure the vacuum concurrently. The two pCAVS together detected a leak with a rate on the order of $10^{-6}$ Pa L/s. After fixing the leak, the pCAVS measured a pressure of about 40 nPa with 2.6 % uncertainty. The two pCAVS agree within their uncertainties, even when swapping some of their component parts. Operation of the pCAVS was found to cause some additional outgassing, on the order of $10^{-8}$ Pa L/s, which can be mitigated in the future by better thermal management.

preprint2018arXiv

Nuclear-Spin Dependent Parity Violation in Optically Trapped Polyatomic Molecules

We investigate using optically trapped linear polyatomic molecules as probes of nuclear spin-dependent parity violation. The presence of closely spaced, opposite-parity $\ell$-doublets is a general feature of such molecules, allowing parity-violation-sensitive pairs of levels to be brought to degeneracy in magnetic fields typically 100 times smaller than in diatomics. Assuming laser cooling and trapping of polyatomics at the current state-of-the-art for diatomics, we expect to measure nuclear spin-dependent parity-violating matrix elements $iW$ with 70 times better sensitivity than the current best measurements. Our scheme should allow for 10 \% measurements of $iW$ in nuclei as light as Be or as heavy as Yb, with averaging times on order the of 10 days and 1 second, respectively.