Researcher profile

James A. Fedchak

James A. Fedchak contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2024arXiv

On the effect of "glancing" collisions in the cold atom vacuum standard

We theoretically investigate the effect of ``glancing" collisions on the ultra-high vacuum (UHV) pressure readings of the cold atom vacuum standard (CAVS), based on either ultracold $^7$Li or $^{87}$Rb atoms. Here, glancing collisions are those collisions between ultracold atoms and room-temperature background atoms or molecules in the vacuum that do not impart enough kinetic energy to eject an ultracold atom from its trap. Our model is wholly probabilistic and shows that the number of the ultracold atoms remaining in the trap as a function of time is non-exponential. We update the recent results of a comparison between a traditional pressure standard -- a combined flowmeter and dynamic expansion system -- to the CAVS [D.S. Barker, et al., arXiv:2302.12143] to reflect the results of our model. We find that the effect of glancing collisions shifts the theoretical predictions of the total loss rate coefficients for $^7$Li colliding with noble gases or N$_2$ by up to $0.6$ %. Likewise, we find that in the limit of zero trap depth the experimentally extracted loss rate coefficients for $^{87}$Rb colliding with noble gases or N$_2$ shift by as much as 2.2 %.

preprint2022arXiv

Comparison of two multiplexed portable cold-atom vacuum standards

We compare the vacuum measured by two portable cold-atom vacuum standards (pCAVS) based on ultracold $^7$Li atoms. The pCAVS are quantum-based standards that use a priori scattering calculations to convert a measured loss rate of cold atoms from a conservative trap into a background gas pressure. Our pCAVS devices share the same laser system and measure the vacuum concurrently. The two pCAVS together detected a leak with a rate on the order of $10^{-6}$ Pa L/s. After fixing the leak, the pCAVS measured a pressure of about 40 nPa with 2.6 % uncertainty. The two pCAVS agree within their uncertainties, even when swapping some of their component parts. Operation of the pCAVS was found to cause some additional outgassing, on the order of $10^{-8}$ Pa L/s, which can be mitigated in the future by better thermal management.

preprint2021arXiv

Outgassing rate comparison of seven geometrically similar vacuum chambers of different materials and heat treatments

We have measured the water and hydrogen outgassing rates of seven vacuum chambers of identical geometry but constructed of different materials and heat treatments. Chambers of five different materials were tested: 304L, 316L, and 316LN stainless steels; titanium (ASTM grade 2); and 6061 aluminum. In addition, chambers constructed of 316L and 316LN stainless steel were subjected to a vacuum-fire process, where they were heated to approximately 950 °C for 24 hours while under vacuum; these two chambers are designated as 316L-XHV and 316LN-XHV. All chambers were of identical geometry and made by the same manufacturer, thus a relative comparison of the outgassing rates among these chambers can be made. Water outgassing rates were measured as a function of time using the throughput technique. The water outgassing results for the 316L, 316LN, 316L-XHV, 316LN-XHV were all similar, but lower than those of 304L by a factor of 3 to 5 lower at 10^4 s. The water outgassing results for Ti and Al chambers were close to that of 304L, Ti being slightly lower. Hydrogen outgassing rates were measured using the rate-of-rise method and performed after a low-temperature bake of 125 °C to 150 °C for a minimum of 72 hours. The Ti, Al, 316L-XHV, and 316LN-XHV chambers all have specific outgassing rates below 1 X 10^-11 Pa L s^-1 cm^-2 and are at least a factor of 100 or better than the 304L chamber. The 304L, 316L, and 316LN chambers without vacuum-fire heat treatment have larger hydrogen outgassing rates than the other chambers, with specific outgassing rates ranging between 4.0 X 10^-11 Pa L s^-1 cm^-2 and 8.0 X 10^-11 Pa L s^-1 cm^-2. We conclude that Ti, Al, 316L-XHV, and 316LN-XHV have hydrogen outgassing rates that make them excellent choices for ultra-high vacuum (UHV) and extreme-high vacuum (XHV) applications, the choice depending on cost and other material properties.

preprint2018arXiv

Nuclear-Spin Dependent Parity Violation in Optically Trapped Polyatomic Molecules

We investigate using optically trapped linear polyatomic molecules as probes of nuclear spin-dependent parity violation. The presence of closely spaced, opposite-parity $\ell$-doublets is a general feature of such molecules, allowing parity-violation-sensitive pairs of levels to be brought to degeneracy in magnetic fields typically 100 times smaller than in diatomics. Assuming laser cooling and trapping of polyatomics at the current state-of-the-art for diatomics, we expect to measure nuclear spin-dependent parity-violating matrix elements $iW$ with 70 times better sensitivity than the current best measurements. Our scheme should allow for 10 \% measurements of $iW$ in nuclei as light as Be or as heavy as Yb, with averaging times on order the of 10 days and 1 second, respectively.