Source author record

Juan A. Monsoriu

Juan A. Monsoriu appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

9works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2020arXiv

A new trifocal corneal inlay for presbyopia

Corneal inlays (CIs) are the most recent surgical procedure for the treatment of presbyopia in patients who want complete independence from the use of glasses or contact lenses. Although refractive surgery in presbyopic patients is mostly performed in combination with cataract surgery, when the implantation of an intraocular lens is not necessary, the option of CIs has the advantage of being minimally invasive. Current designs of CIs are, either: small aperture devices, or refractive devices, however, both methods do not have good performance simultaneously at intermediate and near distances in eyes that are unable to accommodate. In the present study, we propose the first design of a trifocal CI, allowing good vision, at the same time, at far, intermediate and near vision in presbyopic eyes. We first demonstrate the good performance of the new inlay in comparison with a commercially available CI by using optical design software. We next confirm experimentally the image forming capabilities of our proposal employing an adaptive optics based optical simulator. This new design also has a number of parameters that can be varied to make personalized trifocal CI, opening up a new avenue for the treatment of presbyopia.

preprint2020arXiv

Influence of the theoretical model eye on the numerical evaluation of fractal intraocular lenses

In this work we present the numerical evaluation of a new design of fractal intraocular lens studied through a ray-tracing program. To determine the monochromatic and polychromatic performance of these lenses in different theoretical model eyes the Modulation Transfer Function (MTF) and the area above the MTF (AMTF) have been used. These merit functions show the same behavior for different values of asphericity (Q), independently from the theoretical model eye, even though there are differences due to the Spherical Aberration (SA) considered in each model.

preprint2016arXiv

Design, characterization and visual performance of a new multizone contact lens

Objectives: To analyze the whole process involved in the production of a new bifocal Multizone Contact Lens (MCL) for presbyopia. Methods: The optical quality of a new MCL was evaluated by ray tracing software in a model eye with pupil different diameters with the lens centered and decentered. A stock of low addition (+1.5 D) MCL for presbyopia was ordered for manufacturing. Power profiles were measured with a contact lens power mapper, processed with a custom software and compared with the theoretical design. Nine lenses from the stock were fitted to presbyopic subjects and the visual performance was evaluated with new APPs for iPad Retina. Results: Numerical simulations showed that the trough the focus curve provided by MCL has an extended depth of focus. The optical quality was not dependent on pupil size and only decreased for lens decentered with a pupil diameter of 4.5 mm. The manufactured MCL showed a smoothed power profile with a less-defined zones. The bias between experimental and theoretical zone sizes was uniform along the optical zone unless for the most central area. Eyes fitted with the manufactured MCL showed an improvement in near Visual Acuity (VA) and near stereopsis. Althouh Contrast Sensitivity (CS) at distance decreased, the defocus curve for contrast showed an extended depth of focus correlated to the ray tracing results. Conclusions: The understanding of vision with MCL requires a process that involves design and characterization for detecting any defect that may have impact in the final visual performance. Keywords: Multifocal contact lenses, design, characterization, visual performance

preprint2016arXiv

Fast and reliable stereopsis measurement at multiple distances with iPad

Purpose: To present a new fast and reliable application for iPad (ST) for screening stereopsis at multiple distances. Methods: A new iPad application (app) based on a random dot stereogram was designed for screening stereopsis at multiple distances. Sixty-five subjects with no ocular diseases and wearing their habitual correction were tested at two different distances: 3 m and at 0.4 m. Results were compared with other commercial tests: TNO (at near) and Howard Dolman (at distance) Subjects were cited one week later in order to repeat the same procedures for assessing reproducibility of the tests. Results: Stereopsis at near was better with ST (40 arcsec) than with TNO (60 arcsec), but not significantly (p = 0.36). The agreement was good (k = 0.604) and the reproducibility was better with ST (k = 0.801) than with TNO (k = 0.715), in fact median difference between days was significant only with TNO (p = 0.02). On the other hand, poor agreement was obtained between HD and ST at far distance (k=0.04), obtaining significant differences in medians (p = 0.001) and poorer reliability with HD (k = 0.374) than with ST (k = 0.502). Conclusions: Screening stereopsis at near with a new iPad app demonstrated to be a fast and realiable. Results were in a good agreement with conventional tests as TNO, but it could not be compared at far vision with HD due to the limited resolution of the iPad.

preprint2016arXiv

Theoretical and experimental study of the normal modes in a coupled two-dimensional system

In this work, the normal modes of a two-dimensional oscillating system have been studied from a theoretical and experimental point of view. The normal frequencies predicted by the Hessian matrix for a coupled two-dimensional particle system are compared to those obtained for a real system consisting of two oscillating smartphones coupled one to the other by springs. Experiments are performed on an air table in order to remove the friction forces. The oscillation data are captured by the acceleration sensor of the smartphones and exported to file for further analysis. The experimental frequencies compare reasonably well with the theoretical predictions, namely, within 1.7 % of discrepancy.

preprint2016arXiv

Two-dimensional relative peripheral refractive error induced by Fractal Contact Lenses for myopia control

Purpose: To assess the peripheral refraction induced by Fractal Contact Lenses (FCLs) in myopic eyes by means of a two-dimensional Relative Peripheral Refractive Error (RPRE) map. Methods: FCLs prototypes were specially manufactured and characterized. This study involved twenty-six myopic subjects ranging from -0.50 D to -7.00 D. The two-dimensional RPRE was measured with an open-field autorefractor by means of tracking targets distributed in a square grid from -30 degrees (deg) nasal to 30 deg temporal and 15 deg superior to -15 deg inferior. Corneal topographies were taken in order to assess correlations between corneal asphericity, lens decentration and RPRE represented in vector components M, J0 and J45. Results: The mean power of the FCLs therapeutic zones was 1.32 +/- 0.28 D. Significant correlations were found between the corneal asphericity and vector components of the RPRE in the nacked eyes. FCLs were decentered a mean of 0.7 +/- 0.19 mm to the temporal cornea. M decreased asymmetrically between nasal and temporal retina after fitting the FCLs with a significant increment of the myopic shift besides 10 deg (p<0.05) and the induced myopic shift at 25 deg and 30 deg decreased with FCLs decentration to temporal cornea. The peak of maximum myopic shift at the peripheral retina (M= -1.3 D) was located at 20 deg. Two-dimensional maps showed uniform significant differences in extreme positions of the visual field in comparison with the horizontal RPRE for M and J0, but not for J45. Conclusions: FCLs measured in myopic eyes showed a similar performance than the reported in previous ray-tracing studies with a small bias explained by the manufacturing process and the lens decentration. Two-dimensional maps are preferable for assessing J45 changes due to the lens.

preprint2012arXiv

Using the mobile phone acceleration sensor in Physics experiments: free and damped harmonic oscillations

The mobile acceleration sensor has been used to in Physics experiments on free and damped oscillations. Results for the period, frequency, spring constant and damping constant match very well to measurements obtained by other methods. The Accelerometer Monitor application for Android has been used to get the outputs of the sensor. Perspectives for the Physics laboratory have also been discussed.

preprint2008arXiv

Fractal Generalized Zone Plates

The construction of fractal generalized zone plates (FraGZPs) from a set of periodic diffractive optical elements with circular symmetry is proposed. This allows us to increase the number of foci of a conventional fractal zone plate (FraZP), keeping the self-similarity property within the axial irradiance. The focusing properties of these fractal diffractive optical elements for points not only along but also in the close vicinity of the optical axis are investigated. In both cases analytical expressions for the irradiance are derived. Numerical simulations of the energetic efficiency of FraGZPs under plane wave illumination are carried out. In addition, some effects on the axial irradiance caused by the variation in area of their transparent rings are shown.

preprint2007arXiv

Tunnelling in quantum superlattices with variable lacunarity

Quantum fractal superlattices are microelectronic devices consisting of a series of thin layers of two semiconductor materials deposited alternately on each other over a substrate following the rules of construction of a fractal set, here, a symmetrical polyadic Cantor fractal. The scattering properties of electrons in these superlattices may be modeled by using that of quantum particles in piecewise constant potential wells. The twist plots representing the reflection coefficient as function of the lacunarity parameter show the appearance of black curves with perfectly transparent tunnelling which may be classified as vertical, arc, and striation nulls. Approximate analytical formulae for these reflection-less curves are derived using the transfer matrix method. Comparison with the numerical results show their good accuracy.