Source author record

Clara Llorens-Quintana

Clara Llorens-Quintana appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2016arXiv

Design, characterization and visual performance of a new multizone contact lens

Objectives: To analyze the whole process involved in the production of a new bifocal Multizone Contact Lens (MCL) for presbyopia. Methods: The optical quality of a new MCL was evaluated by ray tracing software in a model eye with pupil different diameters with the lens centered and decentered. A stock of low addition (+1.5 D) MCL for presbyopia was ordered for manufacturing. Power profiles were measured with a contact lens power mapper, processed with a custom software and compared with the theoretical design. Nine lenses from the stock were fitted to presbyopic subjects and the visual performance was evaluated with new APPs for iPad Retina. Results: Numerical simulations showed that the trough the focus curve provided by MCL has an extended depth of focus. The optical quality was not dependent on pupil size and only decreased for lens decentered with a pupil diameter of 4.5 mm. The manufactured MCL showed a smoothed power profile with a less-defined zones. The bias between experimental and theoretical zone sizes was uniform along the optical zone unless for the most central area. Eyes fitted with the manufactured MCL showed an improvement in near Visual Acuity (VA) and near stereopsis. Althouh Contrast Sensitivity (CS) at distance decreased, the defocus curve for contrast showed an extended depth of focus correlated to the ray tracing results. Conclusions: The understanding of vision with MCL requires a process that involves design and characterization for detecting any defect that may have impact in the final visual performance. Keywords: Multifocal contact lenses, design, characterization, visual performance

preprint2016arXiv

Fast and reliable stereopsis measurement at multiple distances with iPad

Purpose: To present a new fast and reliable application for iPad (ST) for screening stereopsis at multiple distances. Methods: A new iPad application (app) based on a random dot stereogram was designed for screening stereopsis at multiple distances. Sixty-five subjects with no ocular diseases and wearing their habitual correction were tested at two different distances: 3 m and at 0.4 m. Results were compared with other commercial tests: TNO (at near) and Howard Dolman (at distance) Subjects were cited one week later in order to repeat the same procedures for assessing reproducibility of the tests. Results: Stereopsis at near was better with ST (40 arcsec) than with TNO (60 arcsec), but not significantly (p = 0.36). The agreement was good (k = 0.604) and the reproducibility was better with ST (k = 0.801) than with TNO (k = 0.715), in fact median difference between days was significant only with TNO (p = 0.02). On the other hand, poor agreement was obtained between HD and ST at far distance (k=0.04), obtaining significant differences in medians (p = 0.001) and poorer reliability with HD (k = 0.374) than with ST (k = 0.502). Conclusions: Screening stereopsis at near with a new iPad app demonstrated to be a fast and realiable. Results were in a good agreement with conventional tests as TNO, but it could not be compared at far vision with HD due to the limited resolution of the iPad.