Source author record

Vicente Ferrando

Vicente Ferrando appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2020arXiv

A new trifocal corneal inlay for presbyopia

Corneal inlays (CIs) are the most recent surgical procedure for the treatment of presbyopia in patients who want complete independence from the use of glasses or contact lenses. Although refractive surgery in presbyopic patients is mostly performed in combination with cataract surgery, when the implantation of an intraocular lens is not necessary, the option of CIs has the advantage of being minimally invasive. Current designs of CIs are, either: small aperture devices, or refractive devices, however, both methods do not have good performance simultaneously at intermediate and near distances in eyes that are unable to accommodate. In the present study, we propose the first design of a trifocal CI, allowing good vision, at the same time, at far, intermediate and near vision in presbyopic eyes. We first demonstrate the good performance of the new inlay in comparison with a commercially available CI by using optical design software. We next confirm experimentally the image forming capabilities of our proposal employing an adaptive optics based optical simulator. This new design also has a number of parameters that can be varied to make personalized trifocal CI, opening up a new avenue for the treatment of presbyopia.

preprint2020arXiv

Influence of the theoretical model eye on the numerical evaluation of fractal intraocular lenses

In this work we present the numerical evaluation of a new design of fractal intraocular lens studied through a ray-tracing program. To determine the monochromatic and polychromatic performance of these lenses in different theoretical model eyes the Modulation Transfer Function (MTF) and the area above the MTF (AMTF) have been used. These merit functions show the same behavior for different values of asphericity (Q), independently from the theoretical model eye, even though there are differences due to the Spherical Aberration (SA) considered in each model.

preprint2016arXiv

Two-dimensional relative peripheral refractive error induced by Fractal Contact Lenses for myopia control

Purpose: To assess the peripheral refraction induced by Fractal Contact Lenses (FCLs) in myopic eyes by means of a two-dimensional Relative Peripheral Refractive Error (RPRE) map. Methods: FCLs prototypes were specially manufactured and characterized. This study involved twenty-six myopic subjects ranging from -0.50 D to -7.00 D. The two-dimensional RPRE was measured with an open-field autorefractor by means of tracking targets distributed in a square grid from -30 degrees (deg) nasal to 30 deg temporal and 15 deg superior to -15 deg inferior. Corneal topographies were taken in order to assess correlations between corneal asphericity, lens decentration and RPRE represented in vector components M, J0 and J45. Results: The mean power of the FCLs therapeutic zones was 1.32 +/- 0.28 D. Significant correlations were found between the corneal asphericity and vector components of the RPRE in the nacked eyes. FCLs were decentered a mean of 0.7 +/- 0.19 mm to the temporal cornea. M decreased asymmetrically between nasal and temporal retina after fitting the FCLs with a significant increment of the myopic shift besides 10 deg (p<0.05) and the induced myopic shift at 25 deg and 30 deg decreased with FCLs decentration to temporal cornea. The peak of maximum myopic shift at the peripheral retina (M= -1.3 D) was located at 20 deg. Two-dimensional maps showed uniform significant differences in extreme positions of the visual field in comparison with the horizontal RPRE for M and J0, but not for J45. Conclusions: FCLs measured in myopic eyes showed a similar performance than the reported in previous ray-tracing studies with a small bias explained by the manufacturing process and the lens decentration. Two-dimensional maps are preferable for assessing J45 changes due to the lens.