Researcher profile

John G. Hartnett

John G. Hartnett contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
7topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2010arXiv

Colloquium: Comparison of Astrophysical and Terrestrial Frequency Standards

We have re-analyzed the stability of pulse arrival times from pulsars and white dwarfs using several analysis tools for measuring the noise characteristics of sampled time and frequency data. We show that the best terrestrial artificial clocks substantially exceed the performance of astronomical sources as time-keepers in terms of accuracy (as defined by cesium primary frequency standards) and stability. This superiority in stability can be directly demonstrated over time periods up to two years, where there is high quality data for both. Beyond 2 years there is a deficiency of data for clock/clock comparisons and both terrestrial and astronomical clocks show equal performance being equally limited by the quality of the reference timescales used to make the comparisons. Nonetheless, we show that detailed accuracy evaluations of modern terrestrial clocks imply that these new clocks are likely to have a stability better than any astronomical source up to comparison times of at least hundreds of years. This article is intended to provide a correct appreciation of the relative merits of natural and artificial clocks. The use of natural clocks as tests of physics under the most extreme conditions is entirely appropriate; however, the contention that these natural clocks, particularly white dwarfs, can compete as timekeepers against devices constructed by mankind is shown to be doubtful.

preprint2010arXiv

Microwave cavity light shining through a wall optimization and experiment

It has been proposed that microwave cavities can be used in a photon regeneration experiment to search for hidden sector photons. Using two isolated cavities, the presence of hidden sector photons could be inferred from a 'light shining through a wall' phenomenon. The sensitivity of the experiment has strong a dependence on the geometric construction and electromagnetic mode properties of the two cavities. In this paper we perform an in depth investigation to determine the optimal setup for such an experiment. We also describe the results of our first microwave cavity experiment to search for hidden sector photons. The experiment consisted of two cylindrical copper cavities stacked axially inside a single vacuum chamber. At a hidden sector photon mass of 37.78 micro eV we place an upper limit on the kinetic mixing parameter chi = 2.9 * 10^(-5). Whilst this result lies within already established limits our experiment validates the microwave cavity `light shining through a wall' concept. We also show that the experiment has great scope for improvement, potentially able to reduce the current upper limit on the mixing parameter chi by several orders of magnitude.

preprint2010arXiv

Ultra-low vibration pulse-tube cryocooler stabilized cryogenic sapphire oscillator with 10^-16 fractional frequency stability

A low maintenance long-term operational cryogenic sapphire oscillator has been implemented at 11.2 GHz using an ultra-low-vibration cryostat and pulse-tube cryocooler. It is currently the world&#39;s most stable microwave oscillator employing a cryocooler. Its performance is explained in terms of temperature and frequency stability. The phase noise and the Allan deviation of frequency fluctuations have been evaluated by comparing it to an ultra-stable liquid-helium cooled cryogenic sapphire oscillator in the same laboratory. Assuming both contribute equally, the Allan deviation evaluated for the cryocooled oscillator is sigma_y = 1 x 10^-15 tau^-1/2 for integration times 1 < tau < 10 s with a minimum sigma_y = 3.9 x 10^-16 at tau = 20 s. The long term frequency drift is less than 5 x 10^-14/day. From the measured power spectral density of phase fluctuations the single side band phase noise can be represented by L_phi(f) = 10^-14.0/f^4+10^-11.6/f^3+10^-10.0/f^2+10^-10.2/f+ 10^-11.0 for Fourier frequencies 10^-3<f<10^3 Hz in the single oscillator. As a result L_phi approx -97.5 dBc/Hz at 1 Hz offset from the carrier.

preprint2009arXiv

Unknown selection effect simulates redshift periodicity in quasar number counts from Sloan Digital Sky Survey

Discrete Fourier analysis on the quasar number count, as a function of redshift, $z$, calculated from the Sloan Digital Sky Survey DR6 release appears to indicate that quasars have preferred periodic redshifts with redshift intervals of 0.258, 0.312, 0.44, 0.63, and 1.1. However the same periods are found in the mean of the $zConf$ parameter used to flag the reliability of the spectroscopic measurements. It follows that these redshift periods must result from some selection effect, as yet undetermined. It does not signal any intrinsic (quantized) redshifts in the quasars.