Source author record

Joao Almeida

Joao Almeida appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

1works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2019arXiv

Metered reagent injection into microfluidic continuous flow sampling for conductimetric ocean dissolved inorganic carbon sensing

Continuous and autonomous measurement of total dissolved inorganic carbon (TCO2) in the oceans is critical for modelling important climate change factors such as ocean uptake of atmospheric CO2 and ocean acidification. Miniaturised chemical analysis systems are therefore required which are small enough for integration into the existing Argo ocean float network for long-term unattended depth profiling of dissolved CO2 with the accuracy of laboratory bench analysers. A microfluidic conductivity-based approach offers the potential for such miniaturisation. Reagent payload for >3 yr operation is a critical parameter. The precise injection of acid into sample, liberating CO2 from seawater, is addressed here. Laser etched microfluidic snake channel restrictors and asymmetric Y meters were fabricated to adjust the metering ratio between seawater and acid simulants. Laser etching conditions were varied to create a range of channel dimensions down to ~75 microns. Channel flow versus pressure measurements were used to determine hydrodynamic resistances which were compared with finite element simulations using a range of cross-section profiles and areas. Microfluidic metering circuits were constructed from variable resistance snake channels and dimensionally symmetric or asymmetric Y-junctions. Sample to acid volume ratios (meter ratio) up to 100:1 have been achieved with 300 microns wide snake channel for lengths > 1m. At the highest pattern resolution, this would require a footprint of > 600 mm2 (6 x10-4 m2). Circuits based solely on asymmetric Y-junctions gave meter ratios up to 16:1 with a footprint cost of < 40 mm2 and precision values of ~0.2%. Further design and fabrication refinements will be required to ensure the structural and dimensional integrity of such small channels in future integration of metering units into full TCO2 analysis microfluidic circuits.