Researcher profile

Paul Maguire

Paul Maguire contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Methane detection to 1 ppm using machine learning analysis of atmospheric pressure plasma optical emission spectra

Optical emission spectroscopy from a small-volume, 5 uL, atmospheric pressure RF-driven helium plasma was used in conjunction with Partial Least Squares Discriminant Analysis (PLS-DA) for the detection of trace concentrations of methane gas. A limit of detection of 1 ppm was obtained and sample concentrations up to 100 ppm CH4 were classified using a nine-category model. A range of algorithm enhancements were investigated including regularization, simple data segmentation and subset selection, VIP feature selection and wavelength variable compression in order to address the high dimensionality and collinearity of spectral emission data. These approaches showed the potential for significant reduction in the number of wavelength variables and the spectral resolution/bandwidth. Wavelength variable compression exhibited reliable predictive performance, with accuracy values > 97%, under more challenging multi-session train - test scenarios. Simple modelling of plasma electron energy distribution functions highlights the complex cross-sensitivities between the target methane, its dissociation products and atmospheric impurities and their impact on excitation and emission.

preprint2019arXiv

Metered reagent injection into microfluidic continuous flow sampling for conductimetric ocean dissolved inorganic carbon sensing

Continuous and autonomous measurement of total dissolved inorganic carbon (TCO2) in the oceans is critical for modelling important climate change factors such as ocean uptake of atmospheric CO2 and ocean acidification. Miniaturised chemical analysis systems are therefore required which are small enough for integration into the existing Argo ocean float network for long-term unattended depth profiling of dissolved CO2 with the accuracy of laboratory bench analysers. A microfluidic conductivity-based approach offers the potential for such miniaturisation. Reagent payload for >3 yr operation is a critical parameter. The precise injection of acid into sample, liberating CO2 from seawater, is addressed here. Laser etched microfluidic snake channel restrictors and asymmetric Y meters were fabricated to adjust the metering ratio between seawater and acid simulants. Laser etching conditions were varied to create a range of channel dimensions down to ~75 microns. Channel flow versus pressure measurements were used to determine hydrodynamic resistances which were compared with finite element simulations using a range of cross-section profiles and areas. Microfluidic metering circuits were constructed from variable resistance snake channels and dimensionally symmetric or asymmetric Y-junctions. Sample to acid volume ratios (meter ratio) up to 100:1 have been achieved with 300 microns wide snake channel for lengths > 1m. At the highest pattern resolution, this would require a footprint of > 600 mm2 (6 x10-4 m2). Circuits based solely on asymmetric Y-junctions gave meter ratios up to 16:1 with a footprint cost of < 40 mm2 and precision values of ~0.2%. Further design and fabrication refinements will be required to ensure the structural and dimensional integrity of such small channels in future integration of metering units into full TCO2 analysis microfluidic circuits.