Researcher profile

Jiri Kvasnicka

Jiri Kvasnicka contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2026arXiv

Impact of Cold Noise on the tracking performance of ATLAS ITk short strip barrel modules using a charged particle beam

The inner tracking system of the ATLAS experiment will be upgraded to a full silicon detector in 2030 for HL-LHC. The new tracking system is called ITk, the Inner Tracker. It is required to be operable with efficiency higher than 99\% and noise hit occupancy smaller than 0.1\%. During the pre-production phase of the ITk project, many short-strip modules were observed to exhibit so-called "Cold Noise (CN)", wherein clusters of strips displayed very high noise when the modules were operated at temperatures below~$-35\degree$C. To investigate the CN impact and ensure the quality of module production, huge amount of effort have been put in by the collaboration. This paper focuses on the impact of CN on the tracking performance by examining two short strip modules that exhibit CN: one is non-irradiated, while the other one has been irradiated to the maximum expected end-of-lifetime fluence. For each module, the global and single strip tracking performance are evaluated.

preprint2014arXiv

Gain Stabilization of SiPMs

The gain of SiPMs depends both on bias voltage and on temperature. For stable operations, both need to be kept constant. In an ILC calorimeter with millions of channels, this is a challenging task. It is, therefore, desirable to compensate for temperature variations by automatically readjusting the bias voltage. We have designed a bias voltage regulator board to achieve this task. We anticipate an uncertainty on the gain stability at the level of $< 1\%$. First, we present measurements of the gain dependence on temperature and bias voltage for several SiPMs from three different manufacturers and determine their dV/dT dependence. Next, we demonstrate the performance of the gain stability with the bias voltage regulator test board on four SiPMs.

preprint2011arXiv

Beam test of the QMB6 calibration board and HBU0 prototype

We report about the performance of the HBU0 board and the optical calibration system QMB6 in the DESY test beam. A MIP signal was measured on the HBU0 board, providing a reference to the LED amplitude scan, showing an amount of light delivered to each of 12 SiPMs from 0 to 250 MIP at maximum. An ASIC analogue memory cell performance was analyzed in relation with the SiPM signal strength. We observed a non-uniformity and a pedestal shift in the ASIC readout values in the high gain mode for the higher signals strength.