SiPM Gain Stabilization Studies for Adaptive Power Supply

We present herein gain stabilization studies of SiPMs using a climate chamber at CERN. We present results for four detectors not tested before, three from Hamamatsu and one from KETEK. Two of the Hamamatsu SiPMs are novel sensors with trenches that reduce cross talk. We use an improved readout system with a digital oscilloscope controlled with a dedicated LabView program. We improved and automized the analysis to deal with large datasets. We have measured the gain-versus-bias-voltage dependence at fixed temperature and gain-versus-temperature dependence at fixed bias voltage to determine the bias voltage dependence on temperature $V(T)$ for stable gain. We show that the gain remains stable to better than $\pm 0.5\%$ in the $20^\circ \rm C - 30^\circ C$ temperature range if the bias voltage is properly adjusted with temperature.

preprint2014arXiv

Gain Stabilization of SiPMs

The gain of SiPMs depends both on bias voltage and on temperature. For stable operations, both need to be kept constant. In an ILC calorimeter with millions of channels, this is a challenging task. It is, therefore, desirable to compensate for temperature variations by automatically readjusting the bias voltage. We have designed a bias voltage regulator board to achieve this task. We anticipate an uncertainty on the gain stability at the level of $< 1\%$. First, we present measurements of the gain dependence on temperature and bias voltage for several SiPMs from three different manufacturers and determine their dV/dT dependence. Next, we demonstrate the performance of the gain stability with the bias voltage regulator test board on four SiPMs.

preprint2011arXiv

Beam test of the QMB6 calibration board and HBU0 prototype

We report about the performance of the HBU0 board and the optical calibration system QMB6 in the DESY test beam. A MIP signal was measured on the HBU0 board, providing a reference to the LED amplitude scan, showing an amount of light delivered to each of 12 SiPMs from 0 to 250 MIP at maximum. An ASIC analogue memory cell performance was analyzed in relation with the SiPM signal strength. We observed a non-uniformity and a pedestal shift in the ASIC readout values in the high gain mode for the higher signals strength.