Source author record

Gerald Eigen

Gerald Eigen appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

8works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2020arXiv

Light Yield and Uniformity Measurements of Different Scintillator Tiles with Silicon Photomultipliers

We present light yield and uniformity measurements of square and hexagonal tiles read out with silicon photomultipliers via a Y11 wavelength-shifting fiber or directly from the side or from the center at the top face. All tiles are 3~mm thick and have an area of $\rm 9~cm^2$. The sides are wrapped with two layers of Teflon tape while top and bottom faces are covered with two layers of Tyvec paper. We further show the first light yield and uniformity measurements of ATLAS Tile Calorimeter (TileCal) tiles with MPPC readout. This study has been motivated by looking into a possible phase 3 upgrade for the ATLAS hadron calorimeter and for hadron calorimeters at future hadron colliders.

preprint2016arXiv

SiPM Gain Stabilization Studies for Adaptive Power Supply

We present herein gain stabilization studies of SiPMs using a climate chamber at CERN. We present results for four detectors not tested before, three from Hamamatsu and one from KETEK. Two of the Hamamatsu SiPMs are novel sensors with trenches that reduce cross talk. We use an improved readout system with a digital oscilloscope controlled with a dedicated LabView program. We improved and automized the analysis to deal with large datasets. We have measured the gain-versus-bias-voltage dependence at fixed temperature and gain-versus-temperature dependence at fixed bias voltage to determine the bias voltage dependence on temperature $V(T)$ for stable gain. We show that the gain remains stable to better than $\pm 0.5\%$ in the $20^\circ \rm C - 30^\circ C$ temperature range if the bias voltage is properly adjusted with temperature.

preprint2014arXiv

Gain Stabilization of SiPMs

The gain of SiPMs depends both on bias voltage and on temperature. For stable operations, both need to be kept constant. In an ILC calorimeter with millions of channels, this is a challenging task. It is, therefore, desirable to compensate for temperature variations by automatically readjusting the bias voltage. We have designed a bias voltage regulator board to achieve this task. We anticipate an uncertainty on the gain stability at the level of $< 1\%$. First, we present measurements of the gain dependence on temperature and bias voltage for several SiPMs from three different manufacturers and determine their dV/dT dependence. Next, we demonstrate the performance of the gain stability with the bias voltage regulator test board on four SiPMs.

preprint2013arXiv

Global CKM Fits with the Scan Method

We present results of a unitary triangle fit based on the scan method. This frequentist approach employs Gaussian uncertainties for experimental quantities, but makes no arbitrary assumptions about the distribution of theoretical errors. Instead, we perform a large number of fits, scanning over regions of plausible theory errors for each quantity, and retain those fits meeting a specific confidence level criterion, thereby constraining the $\bar ρ- \bar η$ plane using the standard input measurements (CKM matrix elements, $\sin2 β, B^0_{d,s}$ mixing, $ε_K$) as well as branching fraction and \CP asymmetry measurements of B decays to $PP, PV, VV$, and $a_1 P$ final states to determine $α$, $D^{(*)}K^{(*)}$ modes to determine $γ$, and $D^{(*)}π$ and $Dρ$ modes to determine $2β+γ$. We parameterize individual decay amplitudes in terms of color-allowed tree, color-suppressed tree, penguin, singlet penguin, electroweak penguin, as well as $W$-exchange and $W$-annihilation amplitudes. With this parameterization, we obtain a good fit to the measured branching fractions and \CP asymmetries within the Standard Model {\it ansatz}, with no new physics contributions. This simultaneous fit allows us to determine the correlation between $α$ and $β$ as well as between $γ$ and $β$.

preprint2013arXiv

Physics at the CLIC e+e- Linear Collider -- Input to the Snowmass process 2013

This paper summarizes the physics potential of the CLIC high-energy e+e- linear collider. It provides input to the Snowmass 2013 process for the energy-frontier working groups on The Higgs Boson (HE1), Precision Study of Electroweak Interactions (HE2), Fully Understanding the Top Quark (HE3), as well as The Path Beyond the Standard Model -- New Particles, Forces, and Dimensions (HE4). It is accompanied by a paper describing the CLIC accelerator study, submitted to the Frontier Capabilities group of the Snowmass process.

preprint2013arXiv

Radiative Penguin Decays at e^+ e^- Colliders

In this review, the most recent results of the radiative decays B -> X_s gamma, B -> K^{(*)} l^+ l^-$ and B -> pi/eta l^+ l^- at e^+e^- colliders are discussed. The new, most precise CP asymmetry measurements in B -> X_s gamma from BABAR are presented together with branching fractions and photon energy moments. For B -> K^{(*)} l^+ l^- modes, B factory results on partial branching fractions, rate asymmetries and angular observables are combined with measurements from CDF and the LHC experiments. The first branching fraction upper limits for B -> eta l^+ l^- are shown along with updated upper limits of B -> pi l^+ l^- branching fractions.