Source author record

Jin Keun Seo

Jin Keun Seo appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

9works
8topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2022arXiv

Metal Artifact Reduction with Intra-Oral Scan Data for 3D Low Dose Maxillofacial CBCT Modeling

Low-dose dental cone beam computed tomography (CBCT) has been increasingly used for maxillofacial modeling. However, the presence of metallic inserts, such as implants, crowns, and dental filling, causes severe streaking and shading artifacts in a CBCT image and loss of the morphological structures of the teeth, which consequently prevents accurate segmentation of bones. A two-stage metal artifact reduction method is proposed for accurate 3D low-dose maxillofacial CBCT modeling, where a key idea is to utilize explicit tooth shape prior information from intra-oral scan data whose acquisition does not require any extra radiation exposure. In the first stage, an image-to-image deep learning network is employed to mitigate metal-related artifacts. To improve the learning ability, the proposed network is designed to take advantage of the intra-oral scan data as side-inputs and perform multi-task learning of auxiliary tooth segmentation. In the second stage, a 3D maxillofacial model is constructed by segmenting the bones from the dental CBCT image corrected in the first stage. For accurate bone segmentation, weighted thresholding is applied, wherein the weighting region is determined depending on the geometry of the intra-oral scan data. Because acquiring a paired training dataset of metal-artifact-free and metal artifact-affected dental CBCT images is challenging in clinical practice, an automatic method of generating a realistic dataset according to the CBCT physics model is introduced. Numerical simulations and clinical experiments show the feasibility of the proposed method, which takes advantage of tooth surface information from intra-oral scan data in 3D low dose maxillofacial CBCT modeling.

preprint2020arXiv

Automated 3D cephalometric landmark identification using computerized tomography

Identification of 3D cephalometric landmarks that serve as proxy to the shape of human skull is the fundamental step in cephalometric analysis. Since manual landmarking from 3D computed tomography (CT) images is a cumbersome task even for the trained experts, automatic 3D landmark detection system is in a great need. Recently, automatic landmarking of 2D cephalograms using deep learning (DL) has achieved great success, but 3D landmarking for more than 80 landmarks has not yet reached a satisfactory level, because of the factors hindering machine learning such as the high dimensionality of the input data and limited amount of training data due to ethical restrictions on the use of medical data. This paper presents a semi-supervised DL method for 3D landmarking that takes advantage of anonymized landmark dataset with paired CT data being removed. The proposed method first detects a small number of easy-to-find reference landmarks, then uses them to provide a rough estimation of the entire landmarks by utilizing the low dimensional representation learned by variational autoencoder (VAE). Anonymized landmark dataset is used for training the VAE. Finally, coarse-to-fine detection is applied to the small bounding box provided by rough estimation, using separate strategies suitable for mandible and cranium. For mandibular landmarks, patch-based 3D CNN is applied to the segmented image of the mandible (separated from the maxilla), in order to capture 3D morphological features of mandible associated with the landmarks. We detect 6 landmarks around the condyle all at once, instead of one by one, because they are closely related to each other. For cranial landmarks, we again use VAE-based latent representation for more accurate annotation. In our experiment, the proposed method achieved an averaged 3D point-to-point error of 2.91 mm for 90 landmarks only with 15 paired training data.

preprint2020arXiv

Deep Learning-Based Solvability of Underdetermined Inverse Problems in Medical Imaging

Recently, with the significant developments in deep learning techniques, solving underdetermined inverse problems has become one of the major concerns in the medical imaging domain. Typical examples include undersampled magnetic resonance imaging, interior tomography, and sparse-view computed tomography, where deep learning techniques have achieved excellent performances. Although deep learning methods appear to overcome the limitations of existing mathematical methods when handling various underdetermined problems, there is a lack of rigorous mathematical foundations that would allow us to elucidate the reasons for the remarkable performance of deep learning methods. This study focuses on learning the causal relationship regarding the structure of the training data suitable for deep learning, to solve highly underdetermined inverse problems. We observe that a majority of the problems of solving underdetermined linear systems in medical imaging are highly non-linear. Furthermore, we analyze if a desired reconstruction map can be learnable from the training data and underdetermined system.

preprint2016arXiv

Mathematical framework for abdominal electrical impedance tomography to assess fatness

This paper presents a static electrical impedance tomography (EIT) technique that evaluates abdominal obesity by estimating the thickness of subcutaneous fat. EIT has a fundamental drawback for absolute admittivity imaging because of its lack of reference data for handling the forward modeling errors. To reduce the effect of boundary geometry errors in imaging abdominal fat, we develop a depth-based reconstruction method that uses a specially chosen current pattern to construct reference-like data, which are then used to identify the border between subcutaneous fat and muscle. The performance of the proposed method is demonstrated by numerical simulations using 32-channel EIT system and human like domain.

preprint2015arXiv

Mathematical framework for multi-frequency identification of thin insulating and small conductive inhomogeneities

We are aiming to identify the thin insulating inhomogeneities and small conductive inhomogeneities inside an electrically conducting medium by using multi-frequency electrical impedance tomography (mfEIT). The thin insulating inhomogeneities are considered in the form of tubular neighborhood of a curve and small conductive inhomogeneities are regarded as circular disks. Taking advantage of the frequency dependent behavior of insulating objects, we give a rigorous derivation of the potential along thin insulating objects at various frequencies. Asymptotic formula is given to analyze relationship between inhomogeneities and boundary potential at different frequencies. In numerical simulations, spectroscopic images are provided to visualize the reconstructed admittivity at various frequencies. For the view of both kinds of inhomogeneities, an integrated reconstructed image based on principle component analysis (PCA) is provided. Phantom experiments are performed by using Swisstom EIT-Pioneer Set.

preprint2014arXiv

Characterization of Metal Artifacts in X-ray Computed Tomography

Metal streak artifacts in X-ray computerized tomography (CT) are rigorously characterized here using the notion of the wavefront set from microlocal analysis. The metal artifacts are caused mainly from the mismatch of the forward model of the filtered back-projection; the presence of metallic subjects in an imaging subject violates the model's assumption of the CT sinogram data being the Radon transform of an image. The increasing use of metallic implants has increased demand for the reduction of metal artifacts in the field of dental and medical radiography. However, it is a challenging issue due to the serious difficulties in analyzing the X-ray data, which depends nonlinearly on the distribution of the metallic subject. In this paper, we found that the metal streaking artifacts cause mainly from the boundary geometry of the metal region. The metal streaking artifacts are produced only when the wavefront set of the Radon transform of the characteristic function of a metal region does not contain the wavefront set of the square of the Radon transform. We also found a sufficient condition for the non-existence of the metal streak artifacts.

preprint2014arXiv

Electrical impedance tomography-based pressure-sensing using conductive membrane

This paper presents a mathematical framework for a flexible pressure-sensor model using electrical impedance tomography (EIT). When pressure is applied to a conductive membrane patch with clamped boundary, the pressure-induced surface deformation results in a change in the conductivity distribution. This change can be detected in the current-voltage data ({\it i.e.,} EIT data) measured on the boundary of the membrane patch. Hence, the corresponding inverse problem is to reconstruct the pressure distribution from the data. The 2D apparent conductivity (in terms of EIT data) corresponding to the surface deformation is anisotropic. Thus, we consider a constrained inverse problem by restricting the coefficient tensor to the range of the map from pressure to 2D-apparent conductivity. This paper provides theoretical grounds for the mathematical model of the inverse problem. We develop a reconstruction algorithm based on a careful sensitivity analysis. We demonstrate the performance of the reconstruction algorithm through numerical simulations to validate its feasibility for future experimental studies.

preprint2014arXiv

Magnetic resonance-based reconstruction method of conductivity and permittivity distributions at the Larmor frequency

Magnetic resonance electrical property tomography is a recent medical imaging modality for visualizing the electrical tissue properties of the human body using radio-frequency magnetic fields. It uses the fact that in magnetic resonance imaging systems the eddy currents induced by the radio-frequency magnetic fields reflect the conductivity ($σ$) and permittivity ($ε$) distributions inside the tissues through Maxwell's equations. The corresponding inverse problem consists of reconstructing the admittivity distribution ($γ=σ+iωε$) at the Larmor frequency ($ω/2π=$128 MHz for a 3 tesla MRI machine) from the positive circularly polarized component of the magnetic field ${\bf H}=(H_x,H_y,H_z)$. Previous methods are usually based on an assumption of local homogeneity ($\nablaγ\approx 0$) which simplifies the governing equation. However, previous methods that include the assumption of homogeneity are prone to artifacts in the region where $γ$ varies. Hence, recent work has sought a reconstruction method that does not assume local-homogeneity. This paper presents a new magnetic resonance electrical property tomography reconstruction method which does not require any local homogeneity assumption on $γ$. We find that $γ$ is a solution of a semi-elliptic partial differential equation with its coefficients depending only on the measured data $H^+$, which enable us to compute a blurred version of $γ$. To improve the resolution of the reconstructed image, we developed a new optimization algorithm that minimizes the mismatch between the data and the model data as a highly nonlinear function of $γ$. Numerical simulations are presented to illustrate the potential of the proposed reconstruction method.

preprint2014arXiv

Mathematical modeling of mechanical vibration assisted conductivity imaging

This paper aims at mathematically modeling a new multi-physics conductivity imaging system incorporating mechanical vibrations simultaneously applied to an imaging object together with current injections. We perturb the internal conductivity distribution by applying time-harmonic mechanical vibrations on the boundary. This enhances the effects of any conductivity discontinuity on the induced internal current density distribution. Unlike other conductivity contrast enhancing frameworks, it does not require a prior knowledge of a reference data. In this paper, we provide a mathematical framework for this novel imaging modality. As an application of the vibration-assisted impedance imaging framework, we propose a new breast image reconstruction method in electrical impedance tomography (EIT). As its another application, we investigate a conductivity anomaly detection problem and provide an efficient location search algorithm. We show both analytically and numerically that the applied mechanical vibration increases the data sensitivity to the conductivity contrast and enhances the quality of reconstructed images and anomaly detection results. For numerous applications in impedance imaging, the proposed multi-physics method opens a new difference imaging area called the vibration-difference imaging, which can augment the time-difference and also frequency-difference imaging methods for sensitivity improvements.