Researcher profile

Jiazhou Wang

Jiazhou Wang contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - UnverifiedVerification L1Unclaimed author
5works
0followers
7topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2025arXiv

BatteryAgent: Synergizing Physics-Informed Interpretation with LLM Reasoning for Intelligent Battery Fault Diagnosis

Fault diagnosis of lithium-ion batteries is critical for system safety. While existing deep learning methods exhibit superior detection accuracy, their "black-box" nature hinders interpretability. Furthermore, restricted by binary classification paradigms, they struggle to provide root cause analysis and maintenance recommendations. To address these limitations, this paper proposes BatteryAgent, a hierarchical framework that integrates physical knowledge features with the reasoning capabilities of Large Language Models (LLMs). The framework comprises three core modules: (1) A Physical Perception Layer that utilizes 10 mechanism-based features derived from electrochemical principles, balancing dimensionality reduction with physical fidelity; (2) A Detection and Attribution Layer that employs Gradient Boosting Decision Trees and SHAP to quantify feature contributions; and (3) A Reasoning and Diagnosis Layer that leverages an LLM as the agent core. This layer constructs a "numerical-semantic" bridge, combining SHAP attributions with a mechanism knowledge base to generate comprehensive reports containing fault types, root cause analysis, and maintenance suggestions. Experimental results demonstrate that BatteryAgent effectively corrects misclassifications on hard boundary samples, achieving an AUROC of 0.986, which significantly outperforms current state-of-the-art methods. Moreover, the framework extends traditional binary detection to multi-type interpretable diagnosis, offering a new paradigm shift from "passive detection" to "intelligent diagnosis" for battery safety management.

preprint2022arXiv

An Efficient and Robust System for Vertically Federated Random Forest

As there is a growing interest in utilizing data across multiple resources to build better machine learning models, many vertically federated learning algorithms have been proposed to preserve the data privacy of the participating organizations. However, the efficiency of existing vertically federated learning algorithms remains to be a big problem, especially when applied to large-scale real-world datasets. In this paper, we present a fast, accurate, scalable and yet robust system for vertically federated random forest. With extensive optimization, we achieved $5\times$ and $83\times$ speed up over the SOTA SecureBoost model \cite{cheng2019secureboost} for training and serving tasks. Moreover, the proposed system can achieve similar accuracy but with favorable scalability and partition tolerance. Our code has been made public to facilitate the development of the community and the protection of user data privacy.

preprint2022arXiv

First implementation of full-workflow automation in radiotherapy: the All-in-One solution on rectal cancer

The aim of this work is to describe the technical characteristics of an AI-powered radiotherapy workflow that enables full-process automation (All-in-One), evaluate its performance implemented for on-couch initial treatment of rectal cancer, and provide insight into the behavior of full-workflow automation in the specialty of radiotherapy. The All-in-One workflow was developed based on a CT-integrated linear accelerator. It incorporates routine radiotherapy procedures from simulation, autosegmentation, autoplanning, image guidance, beam delivery, and in vivo quality assurance (QA) into one scheme, with critical decision points involved, while the patient is on the treatment couch during the whole process. For the enrolled ten patients with rectal cancer, minor modifications of the autosegmented target volumes were required, and the Dice similarity coefficient and 95% Hausdorff distance before and after modifications were 0.892{\pm}0.061 and 18.2{\pm}13.0 mm, respectively. The autosegmented normal tissues and automatic plans were clinically acceptable without any modifications or reoptimization. The pretreatment IGRT corrections were within 2 mm in all directions, and the EPID-based in vivo QA showed a γ passing rate better than 97{\%} (3{\%}/3 mm/10{\%} threshold). The duration of the whole process was 23.2{\pm}3.5 minutes, depending mostly on the time required for manual modification and plan evaluation. The All-in-One workflow enables full automation of the entire radiotherapy process by seamlessly integrating multiple routine procedures. The one-stop solution shortens the time scale it takes to ready the first treatment from days to minutes, significantly improving the patient experience and the efficiency of the workflow, and shows potential to facilitate the clinical application of online adaptive replanning.

preprint2022arXiv

Multi-stage Moving Target Defense: A Security-enhanced D-FACTS Implementation Approach

In recent studies, moving target defense (MTD) has been applied to detect false data injection (FDI) attacks using distributed flexible AC transmission system (D-FACTS) devices. However, the inherent conflict between the security goals of MTD (i.e., detecting FDI attacks) and the economic goals of D-FACTS devices (i.e., reducing power losses) would impede the application of MTD in real systems. Moreover, the detection capabilities of existing MTDs are often insufficient. This paper proposes a multi-stage MTD (MMTD) approach to resolve these two issues by adding a group of designed security-oriented schemes before D-FACTS' economic-oriented scheme to detect FDI attacks. We keep these security-oriented schemes for a very short time interval and then revert to the economic-oriented scheme for the remaining time to ensure the economic requirements. We prove that a designed MMTD can significantly improve the detection capability compared to existing one-stage MTDs. We find the supremum of MMTD's detection capability and study its relationship with system topology and D-FACTS deployment. Meanwhile, a greedy algorithm is proposed to search the MMTD strategy to reach this supremum. Simulation results show that the proposed MMTD can achieve the supremum against FDI attacks while outperforming current MTD strategies on economic indicators.

preprint2020arXiv

Data-driven dose calculation algorithm based on deep learning

In this study we performed a feasibility investigation on implementing a fast and accurate dose calculation based on a deep learning technique. A two dimensional (2D) fluence map was first converted into a three dimensional (3D) volume using ray traversal algorithm. A 3D U-Net like deep residual network was then established to learn a mapping between this converted 3D volume, CT and 3D dose distribution. Therefore an indirect relationship was built between a fluence map and its corresponding 3D dose distribution without using significantly complex neural networks. 200 patients, including nasopharyngeal, lung, rectum and breast cancer cases, were collected and applied to train the proposed network. Additional 47 patients were randomly selected to evaluate the accuracy of the proposed method through comparing dose distributions, dose volume histograms (DVH) and clinical indices with the results from a treatment planning system (TPS), which was used as the ground truth in this study. Results: The proposed deep learning based dose calculation algorithm achieved good predictive performance. For 47 tested patients, the average per-voxel bias of the deep learning calculated value and standard deviation (normalized to the prescription), relative to the TPS calculation, is 0.17%. The average deep learning calculated values and standard deviations for relevant clinical indices were compared with the TPS calculated results and the t-test p-values demonstrated the consistency between them. Conclusions: In this study we developed a new deep learning based dose calculation method. This approach was evaluated by the clinical cases with different sites. Our results demonstrated its feasibility and reliability and indicated its great potential to improve the efficiency and accuracy of radiation dose calculation for different treatment modalities