Source author record

Jianing Dong

Jianing Dong appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

Radiation hardness study on a CMOS pixel sensor for charged particle tracking

A CMOS pixel sensor, named Supix-1, is developed for a pixelated silicon tracker for the Circular Electron-Positron Collider (CEPC) project. The sensor, consisted of nine sectors varying in pixel sizes, diode sizes and geometries, is fabricated with a 180 nm CMOS Image Sensor (CIS) process to study the particle detection performance of enlarged pixels. In this work, the radiation-induced effects on the charge collection of the sensor under the fluence of 1 $\times$ 10^13 1 MeV neq/cm^2 are studied by the measurements with the radioactive source of Fe-55 and the Technology Computer Aided Design (TCAD) simulations, since the radiation hardness of 6.8 $\times$ 10^12 1 MeV neq/cm^2 per year for Non-Ionizing Energy Loss (NIEL) effects is required. In measurements, the sensor gain has been calibrated using the k-$α$ peak of Fe-55 before and after irradiation. The pixel-wise equivalent noise charge (ENC), charge collection efficiency (CCE) and signal-to-noise ratio (SNR) were evaluated. The radiation-induced effects on cluster properties are studied through a self-developed reconstruction algorithm. In TCAD simulations, charge collections in 5 $\times$ 5 pixel matrixes for two typical impinging cases of incident particles were simulated with and without irradiation. Both measurements and simulations indicate that enlarged pixels with area of 21 $μ$m $\times$ 84 $μ$m, though suffering greater loss on sensor performance than small pixels do, still have satisfactory noise and charge collection performance after irradiation for particle tracking in the upcoming collider detectors.

preprint2016arXiv

PandaX-III: Searching for Neutrinoless Double Beta Decay with High Pressure $^{136}$Xe Gas Time Projection Chambers

Searching for the Neutrinoless Double Beta Decay (NLDBD) is now regarded as the topmost promising technique to explore the nature of neutrinos after the discovery of neutrino masses in oscillation experiments. PandaX-III (Particle And Astrophysical Xenon Experiment III) will search for the NLDBD of $^{136}$Xe at the China Jin Ping underground Laboratory (CJPL). In the first phase of the experiment, a high pressure gas Time Projection Chamber (TPC) will contain 200 kg, 90% $^{136}$Xe enriched gas operated at 10 bar. Fine pitch micro-pattern gas detector (Microbulk Micromegas) will be used at both ends of the TPC for the charge readout with a cathode in the middle. Charge signals can be used to reconstruct tracks of NLDBD events and provide good energy and spatial resolution. The detector will be immersed in a large water tank to ensure $\sim$5 m of water shielding in all directions. The second phase, a ton-scale experiment, will consist of five TPCs in the same water tank, with improved energy resolution and better control over backgrounds.

preprint2016arXiv

The calibration and electron energy reconstruction of the BGO ECAL of the DAMPE detector

The DArk Matter Particle Explorer (DAMPE) is a space experiment designed to search for dark matter indirectly by measuring the spectra of photons, electrons, and positrons up to 10 TeV. The BGO electromagnetic calorimeter (ECAL) is its main sub-detector for energy measurement. In this paper, the instrumentation and development of the BGO ECAL is briefly described. The calibration on the ground, including the pedestal, minimum ionizing particle (MIP) peak, dynode ratio, and attenuation length with the cosmic rays and beam particles is discussed in detail. Also, the energy reconstruction results of the electrons from the beam test are presented.