Source author record

Xiaolian Wang

Xiaolian Wang appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

10works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

10 published item(s)

preprint2020arXiv

Energy correction based on fluorescence attenuation of DAMPE

The major scientific goals of DArk Matter Particle Explorer (DAMPE) are to study cosmic-ray electrons (including positrons) and gamma rays from 5 GeV to 10 TeV and nuclei from Z = 1 to 26 up to 100 TeV. The deposited energy measured by the Bismuth Germanate Oxide (BGO) calorimeter of DAMPE is affected by fluorescence attenuation in BGO crystals that are 600 mm long. In this work, an in-orbit attenuation calibration method is reported, and energy correction of the sensitive detector unit of the BGO calorimeter is also presented.

preprint2016arXiv

PandaX-III: Searching for Neutrinoless Double Beta Decay with High Pressure $^{136}$Xe Gas Time Projection Chambers

Searching for the Neutrinoless Double Beta Decay (NLDBD) is now regarded as the topmost promising technique to explore the nature of neutrinos after the discovery of neutrino masses in oscillation experiments. PandaX-III (Particle And Astrophysical Xenon Experiment III) will search for the NLDBD of $^{136}$Xe at the China Jin Ping underground Laboratory (CJPL). In the first phase of the experiment, a high pressure gas Time Projection Chamber (TPC) will contain 200 kg, 90% $^{136}$Xe enriched gas operated at 10 bar. Fine pitch micro-pattern gas detector (Microbulk Micromegas) will be used at both ends of the TPC for the charge readout with a cathode in the middle. Charge signals can be used to reconstruct tracks of NLDBD events and provide good energy and spatial resolution. The detector will be immersed in a large water tank to ensure $\sim$5 m of water shielding in all directions. The second phase, a ton-scale experiment, will consist of five TPCs in the same water tank, with improved energy resolution and better control over backgrounds.

preprint2016arXiv

Temperature Dependence Calibration and Correction of the DAMPE BGO Electromagnetic Calorimeter

A BGO electromagnetic calorimeter (ECAL) is built for the DArk Matter Particle Explorer (DAMPE) mission. The effect of temperature on the BGO ECAL was investigated with a thermal vacuum experiment. The light output of a BGO crystal depends on temperature significantly. The temperature coefficient of each BGO crystal bar has been calibrated, and a correction method is also presented in this paper.

preprint2016arXiv

The calibration and electron energy reconstruction of the BGO ECAL of the DAMPE detector

The DArk Matter Particle Explorer (DAMPE) is a space experiment designed to search for dark matter indirectly by measuring the spectra of photons, electrons, and positrons up to 10 TeV. The BGO electromagnetic calorimeter (ECAL) is its main sub-detector for energy measurement. In this paper, the instrumentation and development of the BGO ECAL is briefly described. The calibration on the ground, including the pedestal, minimum ionizing particle (MIP) peak, dynode ratio, and attenuation length with the cosmic rays and beam particles is discussed in detail. Also, the energy reconstruction results of the electrons from the beam test are presented.

preprint2015arXiv

A study of energy correction for the electron beam data in the BGO ECAL of the DAMPE

The DArk Matter Particle Explorer (DAMPE) is an orbital experiment aiming at searching for dark matter indirectly by measuring the spectra of photons, electrons and positrons originating from deep space. The BGO electromagnetic calorimeter is one of the key sub-detectors of the DAMPE, which is designed for high energy measurement with a large dynamic range from 5 GeV to 10 TeV. In this paper, some methods for energy correction are discussed and tried, in order to reconstruct the primary energy of the incident electrons. Different methods are chosen for the appropriate energy ranges. The results of Geant4 simulation and beam test data (at CERN) are presented.

preprint2014arXiv

Experimental spectra analysis in THM with the help of simulation based on Geant4 framework

The Coulomb barrier and electron screening cause difficulties in directly measuring nuclear reaction cross sections of charged particles in astrophysical energies. The Trojan-horse method has been introduced to solve the difficulties as a powerful indirect tool. In order to understand experimental spectra better, Geant4 is employed to simulate the method for the first time. Validity and reliability of the simulation are examined by comparing the experimental data with simulated results. The Geant4 simulation can give useful information to understand the experimental spectra better in data analysis and is beneficial to the design for future related experiments.

preprint2014arXiv

Study on the temperature dependence of BGO light yield

The temperature dependence of BGO coupled with photomultiplier tube R5610A-01 was studied in the range of -30°C~30°C. The temperature coefficient of the BGO and R5610A in whole was tested to be -1.82%. And the temperature coefficient of the gain of the R5610A is -0.44% which was tested in the same situation using a blue LED. Thus the temperature coefficient of BGO's light yield can be evaluated as -1.38%.

preprint2013arXiv

Detection of Alpha Particles and Low Energy Gamma Rays by Thermo-Bonded Micromegas in Xenon Gas

Micromegas is a type of micro-pattern gaseous detector currently under R&D for applications in rare event search experiments. Here we report the performance of a Micromegas structure constructed with a micromesh thermo-bonded to a readout plane, motivated by its potential application in two-phase xenon detectors for dark matter and neutrinoless double beta decay experiments. The study is carried out in pure xenon at room temperature. Measurements with alpha particles from the Americium-241 source showed that gas gains larger than 200 can be obtained at xenon pressure up to 3 atm. Gamma rays down to 8 keV were observed with such a device.

preprint2011arXiv

Hadronic Trigger using electromagnetic calorimeter and particle identification at high-pT with STAR Detector

We derive a new method to improve the statistics of identified particles at high transverse momentum (\pt) using online-triggered events by the Barrel Electro-Magnetic-Calorimeter (BEMC) detector. The BEMC is used to select hadronic interaction and energy deposit from showers created by charged hadrons ($π^{\pm},K^{\pm}$ and $p$($\bar{p}$)) in the BEMC. With this trigger, the statistics of the high \pt particles are significantly enhanced by about a factor of 100 with selection efficiency up to 20%. In addition, resonant states ($ρ^0$, $K^{\star}$) and weak-decay V0 (\Ks and \La(\aLa)) can be constructed by selecting the BEMC-trigger hadron as one of its daughters. We also show that the trigger efficiency can be obtained reliably in simulation and data-driven approaches.