Researcher profile

Jian-Song Wang

Jian-Song Wang contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - Baseline
4works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2016arXiv

Nuclear in-medium effects on $η$ dynamics in proton-nucleus collisions

The dynamics of $η$ meson produced in proton-induced nuclear reactions via the decay of N$^{\ast}(1535)$ has been investigated within the Lanzhou quantum molecular dynamics transport model (LQMD). The in-medium modifications of the $η$ production in dense nuclear matter are included in the model, in which an attractive $η$-nucleon potential is implemented. The impact of the $η$ optical potential on the $η$ dynamics is investigated. It is found that the attractive potential leads to the reduction of high-momentum (kinetic energy) production from the spectra of momentum distributions and inclusive cross sections and increasing the reabsorption process by surrounding nucleons.

preprint2013arXiv

A simulation study of a dual-plate in-room PET system for dose verification in carbon ion therapy

Carbon ion therapy have the ability to overcome the limitation of convertional radiotherapy due to its most energy deposition in selective depth, usually called Bragg peak, which results in increased biological effectiness. During carbon ion therapy, lots positron emitters such as $^{11}$C, $^{15}$O, $^{10}$C are generated in irradiated tissues by nuclear reactions. Immediately after patient irradiation, PET scanners can be used to measure the spatial distribution of positron emitters, which can track the carbon beam to the tissue. In this study, we designed and evaluated an dual-plate in-room PET scanner to monitor patient dose in carbon ion therapy, which is based on GATE simulation platform. A dual-plate PET is designed to avoid interference with the carbon beam line and with patient positioning. Its performance was compared with that of four-head and full-ring PET scanners. The dual-plate, four-head and full-ring PET scanners consisted of 30, 60, 60 detector modules, respectively, with a 36 cm distance between directly opposite detector modules for dose deposition measurements. Each detector module was consisted of a 24$\times$24 array of 2$\times2\times$18 mm$^{3}$ LYSO pixels coupled to a Hamamatsu H8500 PMT. To esitmate the production yield of positron emitters, a 10$\times15\times$15 cm$^{3}$ cuboid PMMA phantom was irradiated with 172, 200, 250 AMeV $^{12}$C beams. 3D images of the activity distribution of the three type scanners are produced by an iterative reconstruction algorithm. By comparing the longitudinal profile of positron emitters, measured along the carbon beam path, we concluded that the development of a dual-plate PET scanner is feasible to monitor the dose distribution for carbon ion therapy.

preprint2013arXiv

Optimum performance investigation of LYSO crystal pixels: A comparison between GATE simulation and experimental data

Monte Carlo simulation plays an important role in the study of time of flight (TOF) positron emission tomography (PET) prototype. As it can incorporate accurate physical modeling of scintillation detection process, from scintillation light generation, the transport of scintillation photos through the crystal(s), to the conversion of these photons into electronic signals. The Geant4 based simulation software GATE can provide a user-friendly simulation platform containing the properties needed. In this work, we developed a dedicated module in GATE simulation tool. Using this module, we simulated the light yield, energy resolution, time resolution of LYSO pixels with the same cross-section ($4\times4 mm^{2}$) of different lengths: 5 mm, 10 mm, 15 mm, 20 mm, 25 mm, coupled to a PMT. The experiments were performed to validate the GATE simulation results. The results indicate that the best time resolution (484.0$\pm$67.5 ps) and energy resolution (13.3$\pm$0.4 %) could be produced by using pixel with length of 5 mm. The module can also be applied to other cases for precisely simulating optical photons propagating in scintillators.

preprint1999arXiv

Isospin Effects of the Critical Behavior in the Lattice Gas Model

Isospin effects of the critical phenomena were studied via Xe isotopes in the frame of lattice gas model. All the critical temperatures for four Xe isotopes are close to 5.5 MeV at the same freeze-out density of about 0.39 $ρ_0$. The critical values of power law parameter of mass distribution, mean multiplicity of intermediate mass fragments (IMF), information entropy and Campi's second moment show minor dependence on the isospin at the critical point.