A simulation study of a dual-plate in-room PET system for dose verification in carbon ion therapy

Carbon ion therapy have the ability to overcome the limitation of convertional radiotherapy due to its most energy deposition in selective depth, usually called Bragg peak, which results in increased biological effectiness. During carbon ion therapy, lots positron emitters such as $^{11}$C, $^{15}$O, $^{10}$C are generated in irradiated tissues by nuclear reactions. Immediately after patient irradiation, PET scanners can be used to measure the spatial distribution of positron emitters, which can track the carbon beam to the tissue. In this study, we designed and evaluated an dual-plate in-room PET scanner to monitor patient dose in carbon ion therapy, which is based on GATE simulation platform. A dual-plate PET is designed to avoid interference with the carbon beam line and with patient positioning. Its performance was compared with that of four-head and full-ring PET scanners. The dual-plate, four-head and full-ring PET scanners consisted of 30, 60, 60 detector modules, respectively, with a 36 cm distance between directly opposite detector modules for dose deposition measurements. Each detector module was consisted of a 24$\times$24 array of 2$\times2\times$18 mm$^{3}$ LYSO pixels coupled to a Hamamatsu H8500 PMT. To esitmate the production yield of positron emitters, a 10$\times15\times$15 cm$^{3}$ cuboid PMMA phantom was irradiated with 172, 200, 250 AMeV $^{12}$C beams. 3D images of the activity distribution of the three type scanners are produced by an iterative reconstruction algorithm. By comparing the longitudinal profile of positron emitters, measured along the carbon beam path, we concluded that the development of a dual-plate PET scanner is feasible to monitor the dose distribution for carbon ion therapy.

preprint2013arXivOpen access

Signal facts

What is known right now

Open access9 authors2 topics

Next steps

Decide what to do with this paper

Use like or dislike for the fast social read. The more specific scholarly feedback stays available below when needed.

Log in to curate

Reading frame

Keep the important context close to the paper

Keep the important signals around this paper in one place: votes, save state, collection context, reviews and the metadata you need before deciding what to do next.

Institutions

Add specific reaction

Move through the context

Research map

Open full explorer

Move through nearby people, institutions, topics and adjacent work without leaving the paper page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Structured reviews

0 review(s)

ContributeLeave structured feedbackUse the review template when you have a concrete strength, concern or method question.Open review form

No structured reviews yet. High-signal critique starts here.

Work discussion

0 comment(s)

DiscussAdd a high-signal commentKeep quick notes, caveats and replication pointers separate from formal reviews.Open comment form

No discussion yet. The first strong comment sets the tone.