Researcher profile

Xiu-Ling Zhang

Xiu-Ling Zhang contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - Baseline
3works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2015arXiv

Study of time resolution by digital methods with DRS4 system

A new Digital Pulse Processing (DPP) system, based on domino ring sampler version 4 (DRS4), with good time resolution for the LaBr3 detectors has been developed and different digital timing analysis methods for processing the detector raw signals are reported. The system, composed of an eight channels DRS4 chip, was used as the readout electronic and acquisition system to process the outputs signals from XP20D0 Photomultiplier Tubes (PMTs). The PMTs were coupled with LaBr3 scintillator and placed on opposite side of the radioactive positron 22Na source for 511keV gama-ray test. By analyzing the raw data acquired by the system, the best coincidence timing resolution is about 194.7ps (FWHM), obtained by the digital constant fraction discrimination (dCFD) method and better than the other digital methods and analysis method based on the conventional analog systems. The results indicate that it is a promising approach to better localize the positron annihilation in the positron emission tomography (PET) with time of flight (TOF) and they are also suitable for the scintillation timing measurement, such as in TOF-DeltaE and TOF-E systems for particle identification, with picosecond accuracy timing measurement. Furthermore, this system is more simple and convenient in comparison with other systems.

preprint2013arXiv

A simulation study of a dual-plate in-room PET system for dose verification in carbon ion therapy

Carbon ion therapy have the ability to overcome the limitation of convertional radiotherapy due to its most energy deposition in selective depth, usually called Bragg peak, which results in increased biological effectiness. During carbon ion therapy, lots positron emitters such as $^{11}$C, $^{15}$O, $^{10}$C are generated in irradiated tissues by nuclear reactions. Immediately after patient irradiation, PET scanners can be used to measure the spatial distribution of positron emitters, which can track the carbon beam to the tissue. In this study, we designed and evaluated an dual-plate in-room PET scanner to monitor patient dose in carbon ion therapy, which is based on GATE simulation platform. A dual-plate PET is designed to avoid interference with the carbon beam line and with patient positioning. Its performance was compared with that of four-head and full-ring PET scanners. The dual-plate, four-head and full-ring PET scanners consisted of 30, 60, 60 detector modules, respectively, with a 36 cm distance between directly opposite detector modules for dose deposition measurements. Each detector module was consisted of a 24$\times$24 array of 2$\times2\times$18 mm$^{3}$ LYSO pixels coupled to a Hamamatsu H8500 PMT. To esitmate the production yield of positron emitters, a 10$\times15\times$15 cm$^{3}$ cuboid PMMA phantom was irradiated with 172, 200, 250 AMeV $^{12}$C beams. 3D images of the activity distribution of the three type scanners are produced by an iterative reconstruction algorithm. By comparing the longitudinal profile of positron emitters, measured along the carbon beam path, we concluded that the development of a dual-plate PET scanner is feasible to monitor the dose distribution for carbon ion therapy.

preprint2013arXiv

Optimum performance investigation of LYSO crystal pixels: A comparison between GATE simulation and experimental data

Monte Carlo simulation plays an important role in the study of time of flight (TOF) positron emission tomography (PET) prototype. As it can incorporate accurate physical modeling of scintillation detection process, from scintillation light generation, the transport of scintillation photos through the crystal(s), to the conversion of these photons into electronic signals. The Geant4 based simulation software GATE can provide a user-friendly simulation platform containing the properties needed. In this work, we developed a dedicated module in GATE simulation tool. Using this module, we simulated the light yield, energy resolution, time resolution of LYSO pixels with the same cross-section ($4\times4 mm^{2}$) of different lengths: 5 mm, 10 mm, 15 mm, 20 mm, 25 mm, coupled to a PMT. The experiments were performed to validate the GATE simulation results. The results indicate that the best time resolution (484.0$\pm$67.5 ps) and energy resolution (13.3$\pm$0.4 %) could be produced by using pixel with length of 5 mm. The module can also be applied to other cases for precisely simulating optical photons propagating in scintillators.