Source author record

Jean-Michel Friedt

Jean-Michel Friedt appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2021arXiv

Digital Doppler-cancellation servo for ultra-stable optical frequency dissemination over fiber

Progress made in optical references, including ultra-stable Fabry-Perot cavities, optical frequency combs and optical atomic clocks, have driven the need for ultra-stable optical fiber networks. Telecom-wavelength ultra-pure optical signal transport has been demonstrated on distances ranging from the laboratory scale to the continental scale. In this manuscript, we present a Doppler-cancellation setup based on a digital phase-locked loop for ultra-stable optical signal dissemination over fiber. The optical phase stabilization setup is based on a usual heterodyne Michelson-interferometer setup, while the Software Defined Radio (SDR) implementation of the phase-locked loop is based on a compact commercial board embedding a field programmable gate array, analog-to-digital and digital-to-analog converters. Using three different configurations including an undersampling method, we demonstrate a 20 m long fiber link with residual fractional frequency instability as low as $10^{-18}$ at 1000 s, and an optical phase noise of $-70$ dBc/Hz at 1 Hz with a telecom frequency carrier.

preprint2020arXiv

Phase Sensitivity and Phase Noise of Cantilever-Type Magnetoelastic Sensors Based on the $Δ$E Effect

Magnetoelastic sensors for the detection of low-frequency and low-amplitude magnetic fields are in the focus of research since more than 30 years. In order to minimize the limit of detection (LOD) of such sensor systems, it is of high importance to understand and to be able to quantify the relevant noise sources. In this contribution, cantilever-type electromechanic and magnetoelastic resonators, respectively, are comprehensively investigated and mathematically described not only with regard to their phase sensitivity but especially to the extent of the sensor-intrinsic phase noise. Both measurements and calculations reveal that the fundamental LOD is limited by additive phase noise due to thermal-mechanical noise of the resonator, i.e. by thermally induced random vibrations of the cantilever, and by thermal-electrical noise of the piezoelectric material. However, due to losses in the magnetic material parametric flicker phase noise arises, limiting the overall performance. In particular it is shown that the LOD is virtually independent of the magnetic sensitivity but is solely determined by the magnetic losses. Instead of the sensitivity, the magnetic losses, represented by the material's effective complex permeability, should be considered as the most important parameter for the further improvement of such sensors in the future. This implication is not only valid for magnetoelastic cantilevers but also applies to any type of magnetoelastic resonator.

preprint2020arXiv

Sub-surface H2S detection by a Surface Acoustic Wave passive wireless sensor interrogated with a ground penetrating radar

Long-term monitoring of organic pollutants in the soil is a major environmental challenge. We propose to meet this issue by the development of a polymer dedicated to selectively react with H2S, coating surface acoustic wave transducers designed as passive cooperative targets with the compound, and probing their response using Ground Penetrating RADAR, thus providing the capability to monitor the presence of H2S in the subsurface environment. The selectivity is brought by including lead(II) cation in a reticulated polymer matrix which can be deposited as a thin layer on a surface acoustic wave sensor. We demonstrate a signal enhancement mechanism in which water absorption magnifies the signal detection, making the sensor most sensitive to H2S in an underground environment saturated with moisture.

preprint2019arXiv

Noise Analysis of Open-Loop and Closed-Loop SAW Magnetic Field Sensor Systems

Transmission surface acoustic wave (SAW) sensors are widely used in various fields of application. In order to maximize the limit of detection (LOD) of such sensor systems, it is of high importance to understand and to be able to quantify the relevant noise sources. In this paper, low noise readout systems for the application with a SAW delay line magnetic field sensor in an open-loop and closed-loop configuration are presented and analyzed with regard to their phase noise contribution. By applying oscillator phase noise theory to closed-loop sensor systems, it is shown that the phase noise of the SAW delay line oscillator can be predicted accurately. This allows the derivation of expressions for the limits of detection for both readout structures. Based on these equations, the equivalence between the LOD of open-loop and closed-loop SAW delay line readout can be shown analytically, assuming that the sensor contributes the dominant phase noise. This equality is verified by measurements. These results are applicable to all kinds of phase sensitive delay line sensors.

preprint2016arXiv

Combined surface acoustic wave and surface plasmon resonance measurement of collagen and fibrinogen layers

We use an instrument combining optical (surface plasmon resonance) and acoustic (Love mode acoustic wave device) real-time measurements on a same surface for the identification of water content in collagen and fibrinogen protein layers. After calibration of the surface acoustic wave device sensitivity by copper electrodeposition, the bound mass and its physical properties -- density and optical index -- are extracted from the complementary measurement techniques and lead to thickness and water ratio values compatible with the observed signal shifts. Such results are especially usefully for protein layers with a high water content as shown here for collagen on an hydrophobic surface. We obtain the following results: collagen layers include 70+/-20 % water and are 16+/-3 to 19+/-3 nm thick for bulk concentrations ranging from 30 to 300 ug/ml. Fibrinogen layers include 50+/-10 % water for layer thicknesses in the 6+/-1.5 to 13+/-2 nm range when the bulk concentration is in the 46 to 460 ug/ml range.

preprint2015arXiv

A HBAR-oscillator-based 4.596~GHz frequency source: Application to a coherent population trapping Cs vapor cell atomic clock

This article reports on the design and characterization of a high-overtone bulk acoustic wave resonator (HBAR)-oscillator-based 4.596~GHz frequency source. A 2.298~GHz signal, generated by an oscillator constructed around a thermally-controlled two-port AlN-sapphire HBAR resonator with a Q-factor of 24000 at 68$^{\circ}$C, is frequency multiplied by 2 to 4.596~GHz, half of the Cs atom clock frequency. The temperature coefficient of frequency (TCF) of the HBAR is measured to be $-23$~ppm/$^{\circ}$C at 2.298~GHz. The measured phase noise of the 4.596~GHz source is $-105$~dBrad$^2$/Hz at 1~kHz offset and $-150$~dBrad$^2$/Hz at 100~kHz offset. The 4.596~GHz output signal is used as a local oscillator (LO) in a laboratory-prototype Cs microcell-based coherent population trapping (CPT) atomic clock. The signal is stabilized onto the atomic transition frequency by tuning finely a voltage-controlled phase shifter (VCPS) implemented in the 2.298~GHz HBAR-oscillator loop, preventing the need for a high-power-consuming direct digital synthesis (DDS). The short-term fractional frequency stability of the free-running oscillator is 1.8 $\times$ 10$^{-9}$ at one second integration time. In locked regime, the latter is improved in a preliminary proof-of-concept experiment at the level of 6.6 $\times$ 10$^{-11}~τ^{-1/2}$ up to a few seconds and found to be limited by the signal-to-noise ratio of the detected CPT resonance.