Researcher profile

Jan Meijer

Jan Meijer contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
10works
0followers
8topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

10 published item(s)

preprint2026arXiv

Oxygen in diamond: thermal stability of ST1 spin centres and creation of oxygen-pair complexes

Little is known about oxygen-related defects in diamond. Recently, the promising room-temperature spin centre named ST1 was identified as an oxygen centre, but of still unknown atomic structure and thermal stability. In this work, we report on the optically active oxygen-related centres and the conditions for their formation, using ion implantation of oxygen in various conditions of depth and fluence. More specifically, we establish the temperature formation/stability range of the ST1 centre, which has a maximum at about 1100°C and is narrower than for NV centres. In these conditions, optically detected magnetic resonance (ODMR) on small ST1 ensembles was measured with a spin readout contrast of > 20% at 300K. In cathodoluminescence, the 535 nm ST1 peak is not observed. Besides, a broad peak centred at 460 nm is measured for implantation of O$_2$ molecular ions. For an annealing temperature of 1500°C, a different centre is formed (with ZPL at 584.5 nm) with an intensity increasing with a power law 1.5 < p < 1.9 dependence from the implantation fluence. This suggests that this centre contains two oxygen atoms. Besides, a new spectral feature associated to an intrinsic defect was also observed, with four prominent lines (especially at 594nm). Finally, the thermal formation and stability of oxygen centres in diamond presented here are important for the identification of the atomic structure of defects such as the ST1 and possible O$_2$V$_x$ complex by means of ab initio calculations. Indeed, the formation energies and charge states of defect centres are easier to compute than the full energy level scheme, which to date still remains unsuccessful regarding the ST1 centre.

preprint2022arXiv

Defect engineering of silicon with ion pulses from laser acceleration

Defect engineering is foundational to classical electronic device development and for emerging quantum devices. Here, we report on defect engineering of silicon single crystals with ion pulses from a laser accelerator with ion flux levels up to 10^22 ions/cm^2/s. Low energy ions from plasma expansion of the laser-foil target are implanted near the surface and then diffuse into silicon samples that were locally pre-heated by high energy ions. We observe low energy ion fluences of ~10^16 cm^-2, about four orders of magnitude higher than the fluence of high energy (MeV) ions. In the areas of highest energy deposition, silicon crystals exfoliate from single ion pulses. Color centers, predominantly W and G-centers, form directly in response to ion pulses without a subsequent annealing step. We find that the linewidth of G-centers increase in areas with high ion flux much more than the linewidth of W-centers, consistent with density functional theory calculations of their electronic structure. Laser ion acceleration generates aligned pulses of high and low energy ions that expand the parameter range for defect engineering and doping of semiconductors with tunable balances of ion flux, damage rates and local heating.

preprint2022arXiv

Detection of single W-centers in silicon

Controlling the quantum properties of individual fluorescent defects in silicon is a key challenge towards advanced quantum photonic devices prone to scalability. Research efforts have so far focused on extrinsic defects based on impurities incorporated inside the silicon lattice. Here we demonstrate the detection of single intrinsic defects in silicon, which are linked to a tri-interstitial complex called W-center, with a zero-phonon line at 1.218$μ$m. Investigating their single-photon emission properties reveals new information about this common radiation damage center, such as its dipolar orientation and its photophysics. We also identify its microscopic structure and show that although this defect does not feature electronic states in the bandgap, Coulomb interactions lead to excitonic radiative recombination below the silicon bandgap. These results could set the stage for numerous quantum perspectives based on intrinsic luminescent defects in silicon, such as quantum integrated photonics, quantum communications and quantum sensing.

preprint2022arXiv

Microscopic-scale recording of brain neuronal electrical activity using a diamond quantum sensor

An important tool in the investigation of the early stages of neurodegenerative disease is the study of dissected living tissue from the brain of an animal model. Such investigations allow the physical structure of individual neurons and neural circuits to be probed alongside neuronal electrical activity, disruption of which can shed light on the mechanisms of emergence of disease. Existing techniques for recording activity rely on potentially damaging direct interaction with the sample, either mechanically as point electrical probes or via intense focused laser light combined with highly specific genetic modification and/or potentially toxic fluorescent dyes. In this work, we instead perform passive, microscopic-scale recording of electrical activity using a biocompatible quantum sensor based on colour centres in diamond. We record biomagnetic field induced by ionic currents in mouse corpus callosum axons without direct sample interaction, accurately recovering signals corresponding to action potential propagation while demonstrating in situ pharmacology during biomagnetic recording through tetrodotoxin inhibition of voltage gated sodium channels. Our results open a promising new avenue for the microscopic recording of neuronal signals, offering the prospect of high resolution imaging of electrical circuits in the living mammalian brain.

preprint2022arXiv

Nanometers-thick Ferromagnetic Surface Produced by Laser Cutting of Diamond

In this work, we demonstrate that cutting diamond crystals with a laser (532~nm wavelength, 0.5~mJ energy, 200~ns pulse duration at 15~kHz) produces a $\lesssim 20~$nm thick surface layer with magnetic order at room temperature. We have measured the magnetic moment of five natural and six CVD diamond crystals of different size, nitrogen content and surface orientations with a SQUID magnetometer. A robust ferromagnetic response at 300~K is observed only for crystals that were cut with the laser along the (100) surface orientation. The magnetic signals are much weaker for the (110) and negligible for the (111) orientations. We attribute the magnetic order to the disordered graphite layer produced by the laser at the diamond surface. The ferromagnetic signal vanished after chemical etching or after moderate temperature annealing. The obtained results indicate that laser treatment of diamond may pave the way to create ferromagnetic spots at its surface.

preprint2021arXiv

High speed microcircuit and synthetic biosignal widefield imaging using nitrogen vacancies in diamond

The ability to measure the passage of electrical current with high spatial and temporal resolution is vital for applications ranging from inspection of microscopic electronic circuits to biosensing. Being able to image such signals passively and remotely at the same time is of high importance, to measure without invasive disruption of the system under study or the signal itself. A new approach to achieve this utilises point defects in solid state materials, in particular nitrogen vacancy (NV) centres in diamond. Acting as a high density array of independent sensors, addressable opto-electronically and highly sensitive to factors including temperature and magnetic field, these are ideally suited to microscopic widefield imaging. In this work we demonstrate such imaging of signals from a microscopic lithographically patterned circuit at the micrometer scale. Using a new type of lock-in amplifier camera, we demonstrate sub-millisecond (up to 3500 frames-per-second) spatially resolved recovery of AC and pulsed electrical current signals, without aliasing or undersampling. Finally, we demonstrate as a proof of principle the recovery of synthetic signals replicating the exact form of signals in a biological neural network: the hippocampus of a mouse.

preprint2020arXiv

Detection of biological signals from a live mammalian muscle using a diamond quantum sensor

The ability to perform noninvasive, non-contact measurements of electric signals produced by action potentials is essential in biomedicine. A key method to do this is to remotely sense signals by the magnetic field they induce. Existing methods for magnetic field sensing of mammalian tissue, used in techniques such as magnetoencephalography of the brain, require cryogenically cooled superconducting detectors. These have many disadvantages in terms of high cost, flexibility and limited portability as well as poor spatial and temporal resolution. In this work we demonstrate an alternative technique for detecting magnetic fields generated by the current from action potentials in living tissue using nitrogen vacancy centres in diamond. With 50pT/$\sqrt{Hz}$ sensitivity, we show the first measurements of sensing from mammalian tissue with a diamond sensor using mouse muscle optogenetically activated with blue light. We show these measurements can be performed in an ordinary, unshielded lab environment and that the signal can be easily recovered by digital signal processing techniques.

preprint2020arXiv

Optimisation of a diamond nitrogen vacancy centre magnetometer for sensing of biological signals

Sensing of signals from biological processes, such as action potential propagation in nerves, are essential for clinical diagnosis and basic understanding of physiology. Sensing can be performed electrically by placing sensor probes near or inside a living specimen or dissected tissue using well established electrophysiology techniques. However, these electrical probe techniques have poor spatial resolution and cannot easily access tissue deep within a living subject, in particular within the brain. An alternative approach is to detect the magnetic field induced by the passage of the electrical signal, giving the equivalent readout without direct electrical contact. Such measurements are performed today using bulky and expensive superconducting sensors with poor spatial resolution. An alternative is to use nitrogen vacancy (NV) centres in diamond that promise biocompatibilty and high sensitivity without cryogenic cooling. In this work we present advances in biomagnetometry using NV centres, demonstrating magnetic field sensitivity of approximately 100 pT/$\sqrt{Hz}$ in the DC/low frequency range using a setup designed for biological measurements. Biocompatibility of the setup with a living sample (mouse brain slice) is studied and optimized, and we show work toward sensitivity improvements using a pulsed magnetometry scheme. In addition to the bulk magnetometry study, systematic artifacts in NV-ensemble widefield fluorescence imaging are investigated.

preprint2020arXiv

Spectroscopic Investigations of Negatively Charged Tin-Vacancy Centres in Diamond

The recently discovered negatively charged tin-vacancy centre in diamond is a promising candidate for applications in quantum information processing (QIP). We here present a detailed spectroscopic study encompassing single photon emission and polarisation properties, the temperature dependence of emission spectra as well as a detailed analysis of the phonon sideband and Debye-Waller factor. Using photoluminescence excitation spectroscopy (PLE) we probe an energetically higher lying excited state and prove fully lifetime limited linewidths of single emitters at cryogenic temperatures. For these emitters we also investigate the stability of the charge state under resonant excitation. These results provide a detailed insight into the spectroscopic properties of the $\text{SnV}^-$ centre and lay the foundation for further studies regarding its suitability in QIP.

preprint2019arXiv

Spin Measurements of NV Centers Coupled to a Photonic Crystal Cavity

Nitrogen-vacancy (NV) centers feature outstanding properties like a spin coherence time of up to one second as well as a level structure offering the possibility to initialize, coherently manipulate and optically read-out the spin degree of freedom of the ground state. However, only about three percent of their photon emission are channeled into the zero phonon line (ZPL), limiting both the rate of indistinguishable single photons and the signal-to-noise ratio (SNR) of coherent spin-photon interfaces. We here report on the enhancement of the SNR of the optical spin read-out achieved by tuning the mode of a two-dimensional photonic crystal (PhC)cavity into resonance with the NV-ZPL. PhC cavities are fabricated by focused ion beam (FIB) milling in thin reactive ion (RIE) etched ultrapure single crystal diamond membranes featuring modes with Q-factors of up to 8250 at mode volumes below one cubic wavelength. NV centers are produced in the cavities in a controlled fashion by a high resolution atomic force microscope (AFM) implantation technique. On cavity resonance we observe a lifetime shortening from 9.0ns to 8.0ns as well as an enhancement of the ZPL emission by almost one order of magnitude. Although on resonance the collection efficiency of ZPL photons and the spin-dependent fluorescence contrast are reduced, the SNR of the optical spin read-out is almost tripled for the cavity-coupled NV centers.