Researcher profile

Jocelyn Achard

Jocelyn Achard contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - UnverifiedVerification L1Unclaimed author
5works
0followers
7topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2026arXiv

Oxygen in diamond: thermal stability of ST1 spin centres and creation of oxygen-pair complexes

Little is known about oxygen-related defects in diamond. Recently, the promising room-temperature spin centre named ST1 was identified as an oxygen centre, but of still unknown atomic structure and thermal stability. In this work, we report on the optically active oxygen-related centres and the conditions for their formation, using ion implantation of oxygen in various conditions of depth and fluence. More specifically, we establish the temperature formation/stability range of the ST1 centre, which has a maximum at about 1100°C and is narrower than for NV centres. In these conditions, optically detected magnetic resonance (ODMR) on small ST1 ensembles was measured with a spin readout contrast of > 20% at 300K. In cathodoluminescence, the 535 nm ST1 peak is not observed. Besides, a broad peak centred at 460 nm is measured for implantation of O$_2$ molecular ions. For an annealing temperature of 1500°C, a different centre is formed (with ZPL at 584.5 nm) with an intensity increasing with a power law 1.5 < p < 1.9 dependence from the implantation fluence. This suggests that this centre contains two oxygen atoms. Besides, a new spectral feature associated to an intrinsic defect was also observed, with four prominent lines (especially at 594nm). Finally, the thermal formation and stability of oxygen centres in diamond presented here are important for the identification of the atomic structure of defects such as the ST1 and possible O$_2$V$_x$ complex by means of ab initio calculations. Indeed, the formation energies and charge states of defect centres are easier to compute than the full energy level scheme, which to date still remains unsuccessful regarding the ST1 centre.

preprint2022arXiv

Microscopic-scale recording of brain neuronal electrical activity using a diamond quantum sensor

An important tool in the investigation of the early stages of neurodegenerative disease is the study of dissected living tissue from the brain of an animal model. Such investigations allow the physical structure of individual neurons and neural circuits to be probed alongside neuronal electrical activity, disruption of which can shed light on the mechanisms of emergence of disease. Existing techniques for recording activity rely on potentially damaging direct interaction with the sample, either mechanically as point electrical probes or via intense focused laser light combined with highly specific genetic modification and/or potentially toxic fluorescent dyes. In this work, we instead perform passive, microscopic-scale recording of electrical activity using a biocompatible quantum sensor based on colour centres in diamond. We record biomagnetic field induced by ionic currents in mouse corpus callosum axons without direct sample interaction, accurately recovering signals corresponding to action potential propagation while demonstrating in situ pharmacology during biomagnetic recording through tetrodotoxin inhibition of voltage gated sodium channels. Our results open a promising new avenue for the microscopic recording of neuronal signals, offering the prospect of high resolution imaging of electrical circuits in the living mammalian brain.

preprint2020arXiv

Detection of biological signals from a live mammalian muscle using a diamond quantum sensor

The ability to perform noninvasive, non-contact measurements of electric signals produced by action potentials is essential in biomedicine. A key method to do this is to remotely sense signals by the magnetic field they induce. Existing methods for magnetic field sensing of mammalian tissue, used in techniques such as magnetoencephalography of the brain, require cryogenically cooled superconducting detectors. These have many disadvantages in terms of high cost, flexibility and limited portability as well as poor spatial and temporal resolution. In this work we demonstrate an alternative technique for detecting magnetic fields generated by the current from action potentials in living tissue using nitrogen vacancy centres in diamond. With 50pT/$\sqrt{Hz}$ sensitivity, we show the first measurements of sensing from mammalian tissue with a diamond sensor using mouse muscle optogenetically activated with blue light. We show these measurements can be performed in an ordinary, unshielded lab environment and that the signal can be easily recovered by digital signal processing techniques.

preprint2020arXiv

Enhancing surface production of negative ions using nitrogen doped diamond in a deuterium plasma

The production of negative ions is of significant interest for applications including mass spectrometry, particle acceleration, material surface processing, and neutral beam injection for magnetic confinement fusion. Methods to improve the efficiency of the surface production of negative ions, without the use of low work function metals, are of interest for mitigating the complex engineering challenges these materials introduce. In this study we investigate the production of negative ions by doping diamond with nitrogen. Negatively biased ($-20$ V or $-130$ V), nitrogen doped micro-crystalline diamond films are introduced to a low pressure deuterium plasma (helicon source operated in capacitive mode, 2 Pa, 26 W) and negative ion energy distribution functions (NIEDFs) are measured via mass spectrometry with respect to the surface temperature (30$^{\circ}$C to 750$^{\circ}$C) and dopant concentration. The results suggest that nitrogen doping has little influence on the yield when the sample is biased at $-130$ V, but when a relatively small bias voltage of $-20$ V is applied the yield is increased by a factor of 2 above that of un-doped diamond when its temperature reaches 550$^{\circ}$C. The doping of diamond with nitrogen is a new method for controlling the surface production of negative ions, which continues to be of significant interest for a wide variety of practical applications.

preprint2020arXiv

Optimisation of a diamond nitrogen vacancy centre magnetometer for sensing of biological signals

Sensing of signals from biological processes, such as action potential propagation in nerves, are essential for clinical diagnosis and basic understanding of physiology. Sensing can be performed electrically by placing sensor probes near or inside a living specimen or dissected tissue using well established electrophysiology techniques. However, these electrical probe techniques have poor spatial resolution and cannot easily access tissue deep within a living subject, in particular within the brain. An alternative approach is to detect the magnetic field induced by the passage of the electrical signal, giving the equivalent readout without direct electrical contact. Such measurements are performed today using bulky and expensive superconducting sensors with poor spatial resolution. An alternative is to use nitrogen vacancy (NV) centres in diamond that promise biocompatibilty and high sensitivity without cryogenic cooling. In this work we present advances in biomagnetometry using NV centres, demonstrating magnetic field sensitivity of approximately 100 pT/$\sqrt{Hz}$ in the DC/low frequency range using a setup designed for biological measurements. Biocompatibility of the setup with a living sample (mouse brain slice) is studied and optimized, and we show work toward sensitivity improvements using a pulsed magnetometry scheme. In addition to the bulk magnetometry study, systematic artifacts in NV-ensemble widefield fluorescence imaging are investigated.