Researcher profile

Jake S. Bobowski

Jake S. Bobowski contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - Baseline
5works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2026arXiv

Simulating diffusion and disorder-induced localization in random walks and transmission lines

We present two complementary simulations that lead to an exploration of Anderson localization, a phenomenon in which wave diffusion is suppressed in disordered media by interference from multiple scattering. To build intuition, the first models the random walk of classical, non-interacting point-like particles, providing a clear analogy to the way disorder can limit transport. The second examines the propagation of an electromagnetic pulse through a one-dimensional, lossless transmission line with randomly varying propagation constant and characteristic impedance along its length, a system that captures the interference effects essential for true Anderson localization. We evaluate quantitative measures that reveal the transition from normal diffusion to localization of particles in one case, and the exponential confinement of wave energy in the other. Together, these simulations offer a pair of accessible tools for investigating localization phenomena in an instructional setting.

preprint2020arXiv

Calibrated Single-Contact Voltage Sensor for High-Voltage Monitoring Applications

A single-contact voltage sensor designed for accurate measurements of ac voltages across a pair of conductors is described. The sensor design is motivated by remote monitoring applications where accurate voltage measurement of high-voltage transmission lines is required. The body of the sensor is electrically and mechanically attached to a single conductor: either the neutral or high-voltage conductor. A capacitive sensing plate attached to the sensor creates a capacitive voltage divider using the stray capacitance to the non-contacted line. A very high-impedance buffer is used to measure the voltage across the divider output and estimate the line voltage. An important part of the work includes a method of calibrating the sensor such that blind voltage measurements can be made without knowing the exact geometry of the conductors. Other important aspects of the design include a two-stage voltage divider for retaining accuracy and increasing the voltage range of the sensor. The work is supported by extensive numerical simulation models which were used to determine the optimum design for the sensing plate and to evaluate the sensitivity to different configurations including conductor spacing and the height above ground. For calibration values which are accurate to 1%, the line voltage can be measured with an accuracy of 10%. The paper describes the theory, design, and experimental verification of the sensor up to a line voltage of 7.5 kVrms.

preprint2020arXiv

Split superconducting and time-reversal symmetry-breaking transitions, and magnetic order in Sr$_2$RuO$_4$ under uniaxial stress

Among unconventional superconductors, Sr$_2$RuO$_4$ has become a benchmark for experimentation and theoretical analysis because its normal-state electronic structure is known with exceptional precision, and because of experimental evidence that its superconductivity has, very unusually, a spontaneous angular momentum, i.e. a chiral state. This hypothesis of chirality is however difficult to reconcile with recent evidence on the spin part of the order parameter. Measurements under uniaxial stress offer an ideal way to test for chirality, because under uniaxial stress the superconducting and chiral transitions are predicted to split, allowing the empirical signatures of each to be identified separately. Here, we report zerofield muon spin relaxation (ZF-$μ$SR) measurements on crystals placed under uniaxial stresses of up to 1.05 GPa. We report a clear stress-induced splitting between the onset temperatures of superconductivity and time-reversal symmetry breaking, consistent with qualitative expectations for chiral superconductivity. We also report the appearance of unexpected bulk magnetic order under a uniaxial stress of ~ 1.0 GPa in clean Sr$_2$RuO$_4$.

preprint2020arXiv

The Complex Permeability of Split-Ring Resonator Arrays Measured at Microwave Frequencies

We have measured the relative permeability of split-ring resonator (SRR) arrays used in metamaterials designed to have $μ^\prime< 0$ over a narrow range of microwave frequencies. The SRR arrays were loaded into the bore of a loop-gap resonator (LGR) and reflection coefficient measurements were used to determine both the real and imaginary parts of the array&#39;s effective permeability. Data were collected as a function of array size and SRR spacing. The results were compared to those obtained from continuous extended split-ring resonators (ESRRs). The arrays of planar SRRs exhibited enhanced damping and a narrower range of frequencies with $μ^\prime<0$ when compared to the ESRRs. The observed differences in damping, however, were diminished considerably when the array size was expanded from a one-dimensional array of $N$ SRRs to a $2\times 2\times N$ array. Our method can also be used to experimentally determine the effective permeability of other metamaterial designs.

preprint2017arXiv

Probing Split-Ring Resonator Permeabilities with Loop-Gap Resonators

A method is proposed to experimentally determine the effective complex permeability of split-ring resonator (SRR) arrays used in the design of metamaterials at microwave frequencies. We analyze the microwave response of a loop-gap resonator (LGR) whose bore has been partially loaded with one or more SRRs. Our analysis reveals that the resonance frequency, magnetic plasma frequency, and damping constant of the effective permeability of the SRR array can be extracted from fits to the reflection coefficient (S11) of an inductively-coupled LGR. We propose LGR designs that would allow both a one-dimensional array of SRRs and small three-dimensional arrays of SRRs to be characterized. Finally, we demonstrate the method using a toroidal LGR loaded with a single extended SRR of length z.