Researcher profile

Hossein Arabi

Hossein Arabi contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
12works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

12 published item(s)

preprint2022arXiv

A novel shape-based loss function for machine learning-based seminal organ segmentation in medical imaging

Automated medical image segmentation is an essential task to aid/speed up diagnosis and treatment procedures in clinical practices. Deep convolutional neural networks have exhibited promising performance in accurate and automatic seminal segmentation. For segmentation tasks, these methods normally rely on minimizing a cost/loss function that is designed to maximize the overlap between the estimated target and the ground-truth mask delineated by the experts. A simple loss function based on the degrees of overlap (i.e., Dice metric) would not take into account the underlying shape and morphology of the target subject, as well as its realistic/natural variations; therefore, suboptimal segmentation results would be observed in the form of islands of voxels, holes, and unrealistic shapes or deformations. In this light, many studies have been conducted to refine/post-process the segmentation outcome and consider an initial guess as prior knowledge to avoid outliers and/or unrealistic estimations. In this study, a novel shape-based cost function is proposed which encourages/constrains the network to learn/capture the underlying shape features in order to generate a valid/realistic estimation of the target structure. To this end, the Principal Component Analysis (PCA) was performed on a vectorized training dataset to extract eigenvalues and eigenvectors of the target subjects. The key idea was to use the reconstruction weights to discriminate valid outcomes from outliers/erroneous estimations.

preprint2022arXiv

A novel unsupervised covid lung lesion segmentation based on the lung tissue identification

This study aimed to evaluate the performance of a novel unsupervised deep learning-based framework for automated infections lesion segmentation from CT images of Covid patients. In the first step, two residual networks were independently trained to identify the lung tissue for normal and Covid patients in a supervised manner. These two models, referred to as DL-Covid and DL-Norm for Covid-19 and normal patients, respectively, generate the voxel-wise probability maps for lung tissue identification. To detect Covid lesions, the CT image of the Covid patient is processed by the DL-Covid and DL-Norm models to obtain two lung probability maps. Since the DL-Norm model is not familiar with Covid infections within the lung, this model would assign lower probabilities to the lesions than the DL-Covid. Hence, the probability maps of the Covid infections could be generated through the subtraction of the two lung probability maps obtained from the DL-Covid and DL-Norm models. Manual lesion segmentation of 50 Covid-19 CT images was used to assess the accuracy of the unsupervised lesion segmentation approach. The Dice coefficients of 0.985 and 0.978 were achieved for the lung segmentation of normal and Covid patients in the external validation dataset, respectively. Quantitative results of infection segmentation by the proposed unsupervised method showed the Dice coefficient and Jaccard index of 0.67 and 0.60, respectively. Quantitative evaluation of the proposed unsupervised approach for Covid-19 infectious lesion segmentation showed relatively satisfactory results. Since this framework does not require any annotated dataset, it could be used to generate very large training samples for the supervised machine learning algorithms dedicated to noisy and/or weakly annotated datasets.

preprint2022arXiv

Deep Learning-Based Attenuation and Scatter Correction of Brain 18F-FDG PET Images in the Image Domain

Attenuation and scatter correction (AC) is crucial for quantitative Positron Emission Tomography (PET) imaging. Recently, direct application of AC in the image domain using deep learning approaches has been proposed for the hybrid PET/MR and dedicated PET systems that lack accompanying transmission or anatomical imaging. This study set out to investigate deep learning-based AC in the image domain using different input settings.

preprint2022arXiv

Deep Learning-Based Partial Volume Correction in Standard and Low-Dose PET-CT Imaging

A standard dose of radioactive tracer must be delivered into the patients body to obtain high-quality Positron Emission Tomography (PET) images for diagnostic purposes, which raises the risk of radiation harm. A reduced tracer dose, on the other hand, results in poor image quality and a noise-induced quantitative bias in PET imaging. The partial volume effect (PVE), which is the result of PET intrinsic limited spatial resolution, is another source of quality and quantity degradation in PET imaging. The utilization of anatomical information for PVE correction (PVC) is not straightforward due to the internal organ motions, patient involuntary motions, and discrepancies in the appearance and size of the structures in anatomical and functional images. Furthermore, an additional MR imaging session is necessary for anatomical information, which may not be available. We set out to build a deep learning-based framework for predicting partial volume corrected full-dose (FD-PVC) pictures from either standard or low-dose (LD) PET images without requiring any anatomical data in order to provide a joint solution for PVC and denoise low-dose PET images.

preprint2022arXiv

Design and implementation of brain surgery bipolar electrocautery simulator using haptic technology

Surgical simulators have been widely used in training and evaluation of physicians and surgeons. Virtual reality augmented with haptic technology has made it feasible to develop more realistic surgical simulators. In this context, we set out to design and develop a brain surgery bipolar electrocautery simulator using haptic technology. A 3D model of brain tissue was generated based on a brain craniotomy image. Bipolar forceps were also modeled to visually assimilate real forceps. An experiment was developed to assess the learning process of the participants. In this experiment, the volunteers were asked to cauterize a large blood vessel in the brain while minimizing the damage done to the brain tissue. The experiment was performed on 20 volunteers, and statistical analysis was conducted on the learning process and error reduction during the surgery. Next, the volunteers were divided into gamer and non gamer groups. The analysis of the volunteers operation demonstrated that, on average, there was a 5 percent reduction in the percentage of applied force error. It was also shown that the results achieved by the gamer and non gamer group has significant difference with a p value of 0.0001. So, playing computer games would increase hand control, focus, and reflex and positively affect surgery skills.

preprint2022arXiv

Does prior knowledge in the form of multiple low-dose PET images (at different dose levels) improve standard-dose PET prediction?

Reducing the injected dose would result in quality degradation and loss of information in PET imaging. To address this issue, deep learning methods have been introduced to predict standard PET images (S-PET) from the corresponding low-dose versions (L-PET). The existing deep learning-based denoising methods solely rely on a single dose level of PET images to predict the S-PET images. In this work, we proposed to exploit the prior knowledge in the form of multiple low-dose levels of PET images (in addition to the target low-dose level) to estimate the S-PET images.

preprint2022arXiv

Joint brain tumor segmentation from multi MR sequences through a deep convolutional neural network

Brain tumor segmentation is highly contributive in diagnosing and treatment planning. The manual brain tumor delineation is a time-consuming and tedious task and varies depending on the radiologists skill. Automated brain tumor segmentation is of high importance, and does not depend on either inter or intra-observation. The objective of this study is to automate the delineation of brain tumors from the FLAIR, T1 weighted, T2 weighted, and T1 weighted contrast-enhanced MR sequences through a deep learning approach, with a focus on determining which MR sequence alone or which combination thereof would lead to the highest accuracy therein.

preprint2021arXiv

Deep learning-based attenuation correction in the image domain for myocardial perfusion SPECT imaging

Objective: In this work, we set out to investigate the accuracy of direct attenuation correction (AC) in the image domain for the myocardial perfusion SPECT imaging (MPI-SPECT) using two residual (ResNet) and UNet deep convolutional neural networks. Methods: The MPI-SPECT 99mTc-sestamibi images of 99 participants were retrospectively examined. UNet and ResNet networks were trained using SPECT non-attenuation corrected images as input and CT-based attenuation corrected SPECT images (CT-AC) as reference. The Chang AC approach, considering a uniform attenuation coefficient within the body contour, was also implemented. Quantitative and clinical evaluation of the proposed methods were performed considering SPECT CT-AC images of 19 subjects as reference using the mean absolute error (MAE), structural similarity index (SSIM) metrics, as well as relevant clinical indices such as perfusion deficit (TPD). Results: Overall, the deep learning solution exhibited good agreement with the CT-based AC, noticeably outperforming the Chang method. The ResNet and UNet models resulted in the ME (count) of ${-6.99\pm16.72}$ and ${-4.41\pm11.8}$ and SSIM of ${0.99\pm0.04}$ and ${0.98\pm0.05}$, respectively. While the Change approach led to ME and SSIM of ${25.52\pm33.98}$ and ${0.93\pm0.09}$, respectively. Similarly, the clinical evaluation revealed a mean TPD of ${12.78\pm9.22}$ and ${12.57\pm8.93}$ for the ResNet and UNet models, respectively, compared to ${12.84\pm8.63}$ obtained from the reference SPECT CT-AC images. On the other hand, the Chang approach led to a mean TPD of ${16.68\pm11.24}$. Conclusion: We evaluated two deep convolutional neural networks to estimate SPECT-AC images directly from the non-attenuation corrected images. The deep learning solutions exhibited the promising potential to generate reliable attenuation corrected SPECT images without the use of transmission scanning.

preprint2021arXiv

Deep learning-based synthetic CT generation from MR images: comparison of generative adversarial and residual neural networks

Currently, MRI-only radiotherapy (RT) eliminates some of the concerns about using CT images in RT chains such as the registration of MR images to a separate CT, extra dose delivery, and the additional cost of repeated imaging. However, one remaining challenge is that the signal intensities of MRI are not related to the attenuation coefficient of the biological tissue. This work compares the performance of two state-of-the-art deep learning models; a generative adversarial network (GAN) and a residual network (ResNet) for synthetic CTs (sCT) generation from MR images. The brain MR and CT images of 86 participants were analyzed. GAN and ResNet models were implemented for the generation of synthetic CTs from the 3D T1-weighted MR images using a six-fold cross-validation scheme. The resulting sCTs were compared, considering the CT images as a reference using standard metrics such as the mean absolute error (MAE), peak signal-to-noise ratio (PSNR) and the structural similarity index (SSIM). Overall, the ResNet model exhibited higher accuracy in relation to the delineation of brain tissues. The ResNet model estimated the CT values for the entire head region with an MAE of 114.1 HU compared to MAE=-10.9 HU obtained from the GAN model. Moreover, both models offered comparable SSIM and PSNR values, although the ResNet method exhibited a slightly superior performance over the GAN method. We compared two state-of-the-art deep learning models for the task of MR-based sCT generation. The ResNet model exhibited superior results, thus demonstrating its potential to be used for the challenge of synthetic CT generation in PET/MR AC and MR-only RT planning.

preprint2021arXiv

Dosimetric characterization of a new 192Ir pulse dose rate brachytherapy source with the Monte Carlo simulation and thermoluminescent dosimeter

In this study, recommendations of the AAPM TG- 43 (U1) report have been followed to characterize the new 192Ir pulse dose rate source, provided by the Applied Radiation Research School, Nuclear Science and Technology Research Institute in Iran. Dose rate constant, radial dose function, geometry factors, and anisotropy function were calculated according to the relevant American Association of Physicists in Medicine AAPM and TG43 (U1) reports. In this study, 192Ir source was characterized using Monte Carlo simulation in water phantom, and in addition, experimental measurements were carried out using thermoluminescent dosimeters (TLD-100) in plexiglass (PMMA) phantoms. The dose-rate constant for the 192Ir PDR was found to be equal to 1.131 cGyh-1U-1 and 1.173 cGyh-1U-1 with TLD measurement and Monte Carlo simulation, respectively. Also in this study, the geometry function, radial dose functions g(r), and the anisotropy function have been calculated at distances from 0.1 to 16 cm. The dose-rate constant of these calculations has been compared with measured values for an actual 192Ir seed. The results of dosimetry parameters, presented in tabulated and graphical formats, exhibited good agreement to those reported from other commercially available PDR 192Ir sources. The results obtained in this study are in close agreement with the characteristics of the commercially available 192Ir sources. The results obtained in this study can be treated as an initial assessment of this source to be employed in the conventional treatment planning systems subsequent to complementary investigations.

preprint2021arXiv

Monte Carlo-based estimation of patient absorbed dose in 99mTc-DMSA, -MAG3, and -DTPA SPECT imaging using the University of Florida (UF) phantoms

SPECT imaging is one of the common modalities used to examine kidney disease. The radiopharmaceuticals such as 99mTc-MAG3, 99mTc-DTPA, and 99mTc-DMSA are commonly employed for pediatric patients. It is generally accepted that children organs are more sensitive to radiation than adults, due to their growth rate. Therefore, evaluating the absorbed dose in children to avoid irrecoverable damage is highly crucial. In this work, absorbed dose by different organs of children within the SPECT imaging for the above-mentioned radiopharmaceuticals were estimated through the use of Monte Carlo simulation for patients at the ages of 4, 8, 11, and 14-years old. The patients absorbed dose was estimated based on the specific radiopharmaceutical uptake patterns and the age-related human body models. To this end, we used the University of Florida (UF) voxel-wise baby phantoms and the Monte Carlo simulation for the pediatric patients at 4, 8, 11, and 14 years of age. The accuracy of the dosimetric outcomes was evaluated versus the ICRP 128 data. The highest and lowest doses absorbed by the kidneys were 0.48 mGy-MBq and 0.0042 mGy-MBq obtained for 4-year-old and 14-year-old children using 99mTc-DMSA and 99mTc-MAG3 radiopharmaceuticals, respectively. Moreover, in these cases, the relative errors of simulation results compared to the reference ICRP data were 12.1% and 0.95%, respectively. The simulation results were in good agreement with the ICRP 128 data. The results showed that the highest absorbed dose was by kidneys and when 99mTc-DMSA was used. The highest and lowest absorbed dose in the organs occurs when 99mTc-DMSA and 99mTc-MAG3 (in normal renal function) are used, respectively. On the other hand, the results indicated that the dose received by the organs decreases with age.

preprint2021arXiv

Quantitative analysis of image quality in low-dose CT imaging for Covid-19 patients

We set out to simulate four reduced dose-levels (60%-dose, 40%-dose, 20%-dose, and 10%-dose) of standard CT imaging using Beer-Lambert's law across 49 patients infected with COVID-19. Then, three denoising filters, namely Gaussian, Bilateral, and Median, were applied to the different low-dose CT images, the quality of which was assessed prior to and after the application of the various filters via calculation of peak signal-to-noise ratio (PSNR), root mean square error (RMSE), structural similarity index measure (SSIM), and relative CT-value bias, separately for the lung tissue and whole-body. The quantitative evaluation indicated that 10%-dose CT images have inferior quality (with RMSE=322.1-+104.0 HU and bias=11.44-+4.49% in the lung) even after the application of the denoising filters. The bilateral filter exhibited superior performance to suppress the noise and recover the underlying signals in low-dose CT images compared to the other denoising techniques. The bilateral filter led to RMSE and bias of 100.21-+16.47 HU, -0.21-+1.20%, respectively in the lung regions for 20%-dose CT images compared to the Gaussian filter with RMSE=103.46-+15.70 HU and bias=1.02-+1.68%, median filter with RMSE=129.60-+18.09 HU and bias=-6.15-+2.24%, and the nonfiltered 20%-dose CT with RMSE=217.37-+64.66 HU and bias=4.30-+1.85%. In conclusion, the 20%-dose CT imaging followed by the bilateral filtering introduced a reasonable compromise between image quality and patient dose reduction.