Source author record

Hervé Rigneault

Hervé Rigneault appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

13works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

13 published item(s)

preprint2026arXiv

Widefield two-photon random illumination microscopy (2P-RIM)

Biological and biomedical samples are routinely examined using focused two-photon (2P) fluorescence microscopy due to its intrinsic axial sectioning and reduced out-of-focus bleaching. However, 2P imaging often requires excitation intensities that can damage samples through ionization and radical formation. Additionally, the lateral resolution of 2P microscopy is lower compared to linear one-photon (1P) fluorescence microscopy. Widefield 2P microscopy, using cameras, holds promise for reducing photo-toxicity while maintaining high image acquisition rates. Widefield imaging trades the high power and short integration times of sequential single point scanning for the low power and extended integration times of parallel detection across millions of pixels. However, generating effective axial sectioning over arbitrarily large fields of view (FOVs) has remained a challenge. In this work, we introduce 2P Random Illumination Microscopy (2P-RIM), an easy-to-implement 2P widefield technique, that achieves low photo-damage, fast imaging, micrometric axial sectioning, and enhanced lateral resolution for arbitrarily large FOVs. By using widefield speckled illuminations in conjunction with an image standard deviation matching algorithm, 2P-RIM demonstrated multicolor imaging over FOVs greater than 200 um, lateral resolution 220 nm, axial sectioning 2 um, and peak excitation powers about 10 times lower than those used in focused laser scanning microscopy.

preprint2022arXiv

Signal-to-noise ratio analysis of single-pixel detection multiplexing under photon-noise. Cases of Hadamard and Cosine positive modulation

In typical single-pixel detection multiplexing, an unknown object is sequentially illuminated with intensity patterns: the total signal is summed into a single-pixel detector and is then demultiplexed to retrieve the object. Because of measurement noise, the retrieved object differs from the ground truth by some error quantified by the signal-to-noise ratio (SNR). In situations where the noise only arises from the photon counting process, it has not been made clear if single-pixel detection multiplexing leads to a better SNR than simply scanning the object with a focused intensity spot - a modality known as raster scanning. This study theoretically assesses the SNR associated with certain types of single-pixel detection multiplexing, and compares it with raster scanning. In particular, we show that, under photon noise, when the positive intensity modulation is based on Hadamard or Cosine patterns, single-pixel detection multiplexing does not systematically improve the SNR as compared to raster scanning. Instead, it only improves the SNR on object pixels at least $k$ times brighter than the object mean signal $\bar{x}$, where $k$ is a constant that depends on the modulation scheme.

preprint2022arXiv

Tapered multi-core fiber for lensless endoscopes

We present a novel fiber-optic component, a "tapered multi-core fiber (MCF)", designed for integration into ultra-miniaturized endoscopes for minimally invasive two-photon point-scanning imaging and to address the power delivery issue that has faced MCF based lensless endoscopes. With it we achieve experimentally a factor 6.0 increase in two-photon signal yield while keeping the ability to point-scan by the memory effect, and a factor 8.9 sacrificing the memory effect. To reach this optimal design we first develop and validate a fast numerical model capable of predicting the essential properties of an arbitrarily tapered MCF from its structural parameters. We then use this model to identify the tapered MCF design parameters that result in a chosen set of target properties (point-spread function, delivered power, presence or absence of memory effect). We fabricate the identified target designs by stack-and-draw and post-processing on a CO$_{2}$ laser-based glass processing and splicing system. Finally we demonstrate the performance gain of the fabricated tapered MCFs in two-photon imaging when used in a lensless endoscope system. Our results show that tailoring of the taper profile brings new degrees of freedom that can be efficiently exploited for lensless endoscopes.

preprint2021arXiv

Roadmap on Wavefront Shaping and deep imaging in complex media

The last decade has seen the development of a wide set of tools, such as wavefront shaping, computational or fundamental methods, that allow to understand and control light propagation in a complex medium, such as biological tissues or multimode fibers. A vibrant and diverse community is now working on this field, that has revolutionized the prospect of diffraction-limited imaging at depth in tissues. This roadmap highlights several key aspects of this fast developing field, and some of the challenges and opportunities ahead.

preprint2019arXiv

Arago spot formation in the time domain

Using the space-time duality we theoretically and experimentally revisit the Arago spot formation in the time domain and explore the temporal emergence of a bright spot in the time shadow of an initial waveform. We describe the linear regime of propagation using Fresnel's integrals and show that in the presence of Kerr nonlinearity the Arago spot formation is affected depending on the sign of the dispersion. We finally confirm experimentally the Arago spot formation in the time domain using a telecommunication optical fiber platform.

preprint2016arXiv

Extended field-of-view in a lensless endoscope using an aperiodic multicore fiber

We investigate lensless endoscopy using coherent beam combining and aperiodic multicore fibers (MCF). We show that diffracted orders, inherent to MCF with periodically arranged cores, dramatically reduce the field of view (FoV) and that randomness in MCF core positions can increase the FoV up to the diffraction limit set by a single fiber core, while maintaining MCF experimental feasibility. We demonstrate experimentally pixelation-free lensless endoscopy imaging over a 120 micron FoV with an aperiodic MCF designed with widely spaced cores. We show that this system is suitable to perform beam scanning imaging by simply applying a tilt to the proximal wavefront.

preprint2016arXiv

Widefield lensless endoscopy via speckle-correlations

Flexible fiber-optic endoscopes provide a minimally-invasive solution for imaging at depths beyond the reach of conventional microscopes. Current endoscopes require focusing and/or scanning mechanisms at the distal end, which limit miniaturization and frame-rate, and induce aberrations. Alternative lensless solutions are based on adaptive wavefront-correction, but are extremely sensitive to fiber bending. Here, we demonstrate a novel endoscopic approach, which enables single-shot imaging at a variable working distance through a conventional fiber bundle, without the use of any distal optics. Our approach computationally retrieves the object image from a single speckle pattern transmitted through the bundle, exploiting phase information preserved through inherent angular speckle correlations. Unlike conventional fiber-bundle endoscopes, the resulting image is unpixelated, the resolution is diffraction-limited, objects can be imaged at variable working distance, and the technique is completely insensitive to fiber bending. Since no optical elements are required, miniaturization is limited only by the bundle diameter.

preprint2016arXiv

Widefield lensless endoscopy with a multicore fiber

We demonstrate pixelation-free real-time widefield endoscopic imaging through an aperiodic multicore fiber (MCF) without any distal opto-mechanical elements or proximal scanners. Exploiting the memory effect in MCFs the images in our system are directly obtained without any post-processing using a static wavefront correction obtained from a single calibration procedure. Our approach allows for video-rate 3D widefield imaging of incoherently illuminated objects with imaging speed not limited by the wavefront shaping device refresh rate.

preprint2015arXiv

Direct imaging of molecular symmetry by coherent anti-Stokes Raman scattering

Nonlinear optical methods, such as coherent anti-Stokes Raman scattering (CARS) and stimulated Raman scattering (SRS), are able to perform label free imaging, with chemical bonds specificity. Here, we demonstrate that the use of circularly polarized light allows to retrieve not only the chemical nature but also the symmetry of the probed sample, in a single shot measurement. Our symmetry-resolved scheme offers simple access to the local organization of vibrational bonds and as a result provides enhanced image contrast for anisotropic samples as well as an improved chemical selectivity. We quantify the local organization of vibrational bonds on crystalline and biological samples, thus providing new information not accessible by spontaneous Raman and SRS techniques. This work stands for a novel symmetry-resolved contrast in vibrational microscopy, with potential application in biological diagnostic.

preprint2015arXiv

Ultra-thin rigid endoscope: Two-photon imaging through a graded-index multi-mode fiber

Rigid endoscopes like graded-index (GRIN) lenses are known tools in biological imaging, but it is conceptually difficult to miniaturize them. In this letter, we demonstrate an ultra-thin rigid endoscope with a diameter of only 125 microns. In addition, we identify a domain where two-photon endoscopic imaging with fs-pulse excitation is possible. We validate the ultra-thin rigid endoscope consisting of a few cm of graded-index multi-mode fiber by using it to acquire optically sectioned two-photon fluorescence endoscopic images of three-dimensional samples.

preprint2014arXiv

Plasmonic antennas and zero mode waveguides to enhance single molecule fluorescence detection and fluorescence correlation spectroscopy towards physiological concentrations

Single-molecule approaches to biology offer a powerful new vision to elucidate the mechanisms that underpin the functioning of living cells. However, conventional optical single molecule spectroscopy techniques such as Förster fluorescence resonance energy transfer (FRET) or fluorescence correlation spectroscopy (FCS) are limited by diffraction to the nanomolar concentration range, far below the physiological micromolar concentration range where most biological reaction occur. To breach the diffraction limit, zero mode waveguides and plasmonic antennas exploit the surface plasmon resonances to confine and enhance light down to the nanometre scale. The ability of plasmonics to achieve extreme light concentration unlocks an enormous potential to enhance fluorescence detection, FRET and FCS. Single molecule spectroscopy techniques greatly benefit from zero mode waveguides and plasmonic antennas to enter a new dimension of molecular concentration reaching physiological conditions. The application of nano-optics to biological problems with FRET and FCS is an emerging and exciting field, and is promising to reveal new insights on biological functions and dynamics.

preprint2006arXiv

Axial localization of luminophores by partial coherence interferometry

We propose a solution for increasing the axial resolution of confocal microscopes. In the experimental set-up described in this paper an interference phenomenon between two counterpropagating beams is used to determine the axial position of a luminophore. The optical path difference between the two waves, which is related to the position of the luminophore, is recovered thanks to a second interferometer by using partial coherence interferometry demodulation technique. The proposed solution can find applications in biology for localizing with nanometric resolution a small number of tagged species.