Researcher profile

Han Wen

Han Wen contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

Online calibration of a linear micro tomosynthesis scanner

In a linear tomosynthesis scanner designed for imaging histologic samples of several centimeter size at 10 micrometer resolution, the mechanical instability of the scanning stage (+/-10 micrometers) exceeded the resolution of the image system, making it necessary to determine the trajectory of the stage for each scan to avoid blurring and artifacts in the images that would arise from the errors in the geometric information used in 3D reconstruction. We present a method for online calibration by attaching a layer of randomly dispersed micro glass beads or calcium particles to the bottom of the sample stage. The marker layer was easy to produce and proven effective in the calibration procedure.

preprint2022arXiv

Online geometric calibration of a hybrid CT system for ultrahigh-resolution imaging

A hybrid imaging system consisting of a standard CT scanner and a low-profile photon-counting detector insert in contact with the patient's body has been used to produce ultrahigh-resolution images in a limited volume in chest scans of patients. The detector insert is placed on the patient bed as needed and not attached. Thus, its position and orientation in the scanner is dependent on the patient's position and scan settings. To allow accurate image reconstruction, we devised a method of determining the relative geometry of the detector insert and the CT scanner for each scan using fiducial markers. This method uses an iterative registration algorithm to align the markers in the reconstructed volume from the detector insert to that of the concurrent CT scan. After obtaining precise geometric information of the detector insert relative to the CT scanner, the two complementary sets of images are summed together to create a detailed image with reduced artifacts.

preprint2020arXiv

TSA-inspired micro tomosythesis scanner for rapid scouting of histopathology samples

In pathology protocols, each tissue block can generate a large number of sections making it impractical to analyze every section. X-ray microscopy that provides a rapid survey of intact tissue blocks can help pinpoint the relevant structures in 3D space for subsequent analysis, and thus reduce workload and enable further automation downstream. Unlike dedicated virtual histology studies by traditional micro computed tomography (CT), routine scout imaging is constrained by a time window of minutes and minimal sample handling to avoid interfering with the pathology protocols. Traditional micro CT was not able to meet the requirements due to lengthy study times or sample alteration by the introduction of x-ray contrast agents. A form of x-ray tomosynthesis used in security screening was found to be efficient for rapid microscopy of unstained samples. When compared to a commercial micro CT scanner, it provided a 10-fold increase in imaging speed and a 4.8-fold increase in contrast-to-noise ratio. We report the results from a variety of human and animal tissue samples, where it served as an integral step of pathology protocols. In cases of vascular disease, it provided quantitative measurements of calcification in intact samples, which were difficult to obtain by standard pathology procedures. The prospect of continuous and automated screening of many samples in an assembly-line approach is discussed.

preprint2019arXiv

On numerical errors to the fields surrounding a relativistically moving particle in PIC codes

The particle-in-cell (PIC) method is widely used to model the self-consistent interaction between discrete particles and electromagnetic fields. It has been successfully applied to problems across plasma physics including plasma based acceleration, inertial confinement fusion, magnetically confined fusion, space physics, astrophysics, high energy density plasmas. In many cases the physics involves how relativistic particles are generated and interact with plasmas. However, when relativistic particles stream across the grid both in vacuum and in plasma there are many numerical issues that may arise which can lead to incorrect physics. We present a detailed analysis of how discretized Maxwell solvers used in PIC codes can lead to numerical errors to the fields that surround particles that move at relativistic speeds across the grid. Expressions for the axial electric field as integrals in k space are presented. Two types of errors to these expressions are identified. The first arises from errors to the numerator of the integrand and leads to unphysical fields that are antisymmetric about the particle. The second arises from errors to the denominator of the integrand and lead to Cerenkov like radiation in "vacuum". These fields are not anti-symmetric, extend behind the particle, and cause the particle to accelerate or decelerate depending on the solver and parameters. The unphysical fields are studied in detail for two representative solvers - the Yee solver and the FFT based solver. A solution for eliminating these unphysical fields by modifying the k operator in the axial direction is also presented. Using a customized finite difference solver, this solution was successfully implemented into OSIRIS. Results from the customized solver are also presented. This solution will be useful for a beam of particles that all move in one direction with a small angular divergence.