Source author record

Dumitru Mazilu

Dumitru Mazilu appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

Online calibration of a linear micro tomosynthesis scanner

In a linear tomosynthesis scanner designed for imaging histologic samples of several centimeter size at 10 micrometer resolution, the mechanical instability of the scanning stage (+/-10 micrometers) exceeded the resolution of the image system, making it necessary to determine the trajectory of the stage for each scan to avoid blurring and artifacts in the images that would arise from the errors in the geometric information used in 3D reconstruction. We present a method for online calibration by attaching a layer of randomly dispersed micro glass beads or calcium particles to the bottom of the sample stage. The marker layer was easy to produce and proven effective in the calibration procedure.

preprint2022arXiv

Online geometric calibration of a hybrid CT system for ultrahigh-resolution imaging

A hybrid imaging system consisting of a standard CT scanner and a low-profile photon-counting detector insert in contact with the patient's body has been used to produce ultrahigh-resolution images in a limited volume in chest scans of patients. The detector insert is placed on the patient bed as needed and not attached. Thus, its position and orientation in the scanner is dependent on the patient's position and scan settings. To allow accurate image reconstruction, we devised a method of determining the relative geometry of the detector insert and the CT scanner for each scan using fiducial markers. This method uses an iterative registration algorithm to align the markers in the reconstructed volume from the detector insert to that of the concurrent CT scan. After obtaining precise geometric information of the detector insert relative to the CT scanner, the two complementary sets of images are summed together to create a detailed image with reduced artifacts.

preprint2020arXiv

TSA-inspired micro tomosythesis scanner for rapid scouting of histopathology samples

In pathology protocols, each tissue block can generate a large number of sections making it impractical to analyze every section. X-ray microscopy that provides a rapid survey of intact tissue blocks can help pinpoint the relevant structures in 3D space for subsequent analysis, and thus reduce workload and enable further automation downstream. Unlike dedicated virtual histology studies by traditional micro computed tomography (CT), routine scout imaging is constrained by a time window of minutes and minimal sample handling to avoid interfering with the pathology protocols. Traditional micro CT was not able to meet the requirements due to lengthy study times or sample alteration by the introduction of x-ray contrast agents. A form of x-ray tomosynthesis used in security screening was found to be efficient for rapid microscopy of unstained samples. When compared to a commercial micro CT scanner, it provided a 10-fold increase in imaging speed and a 4.8-fold increase in contrast-to-noise ratio. We report the results from a variety of human and animal tissue samples, where it served as an integral step of pathology protocols. In cases of vascular disease, it provided quantitative measurements of calcification in intact samples, which were difficult to obtain by standard pathology procedures. The prospect of continuous and automated screening of many samples in an assembly-line approach is discussed.