preprint2022arXiv

Online calibration of a linear micro tomosynthesis scanner

In a linear tomosynthesis scanner designed for imaging histologic samples of several centimeter size at 10 micrometer resolution, the mechanical instability of the scanning stage (+/-10 micrometers) exceeded the resolution of the image system, making it necessary to determine the trajectory of the stage for each scan to avoid blurring and artifacts in the images that would arise from the errors in the geometric information used in 3D reconstruction. We present a method for online calibration by attaching a layer of randomly dispersed micro glass beads or calcium particles to the bottom of the sample stage. The marker layer was easy to produce and proven effective in the calibration procedure.

preprint2022arXiv

Online geometric calibration of a hybrid CT system for ultrahigh-resolution imaging

A hybrid imaging system consisting of a standard CT scanner and a low-profile photon-counting detector insert in contact with the patient's body has been used to produce ultrahigh-resolution images in a limited volume in chest scans of patients. The detector insert is placed on the patient bed as needed and not attached. Thus, its position and orientation in the scanner is dependent on the patient's position and scan settings. To allow accurate image reconstruction, we devised a method of determining the relative geometry of the detector insert and the CT scanner for each scan using fiducial markers. This method uses an iterative registration algorithm to align the markers in the reconstructed volume from the detector insert to that of the concurrent CT scan. After obtaining precise geometric information of the detector insert relative to the CT scanner, the two complementary sets of images are summed together to create a detailed image with reduced artifacts.

preprint2020arXiv

TSA-inspired micro tomosythesis scanner for rapid scouting of histopathology samples

In pathology protocols, each tissue block can generate a large number of sections making it impractical to analyze every section. X-ray microscopy that provides a rapid survey of intact tissue blocks can help pinpoint the relevant structures in 3D space for subsequent analysis, and thus reduce workload and enable further automation downstream. Unlike dedicated virtual histology studies by traditional micro computed tomography (CT), routine scout imaging is constrained by a time window of minutes and minimal sample handling to avoid interfering with the pathology protocols. Traditional micro CT was not able to meet the requirements due to lengthy study times or sample alteration by the introduction of x-ray contrast agents. A form of x-ray tomosynthesis used in security screening was found to be efficient for rapid microscopy of unstained samples. When compared to a commercial micro CT scanner, it provided a 10-fold increase in imaging speed and a 4.8-fold increase in contrast-to-noise ratio. We report the results from a variety of human and animal tissue samples, where it served as an integral step of pathology protocols. In cases of vascular disease, it provided quantitative measurements of calcification in intact samples, which were difficult to obtain by standard pathology procedures. The prospect of continuous and automated screening of many samples in an assembly-line approach is discussed.

preprint2014arXiv

Spherical-Wave Far-Field Interferometer for Hard X-Ray Phase Contrast Imaging

Low dose, high contrast x-ray imaging is of general interest in medical diagnostic applications. X-ray Mach-Zehnder interferometers using collimated synchrotron beams demonstrate the highest levels of phase contrast under a given exposure dose. However, common x-ray sources emit divergent cone beams. Here, we developed a spherical-wave inline Mach-Zehnder interferometer for phase contrast imaging over an extended area with a broadband and divergent source. The first tabletop system was tested in imaging experiments of a mammographic accreditation phantom and various biological specimens. The noise level of the phase contrast images at a clinical radiation dose corresponded to a 6 nano radian bending of the x-ray wavefront. Un-resolved structures with conventional radiography and near-field interferometer techniques became visible at a fraction of the radiation dose.

preprint2013arXiv

Motionless Phase Stepping in X-Ray Phase Contrast Imaging with a Compact Source

X-ray phase contrast imaging offers a way to visualize the internal structures of an object without the need to deposit any radiation, and thereby alleviate the main concern in x-ray diagnostic imaging procedures today. Grating-based differential phase contrast imaging techniques are compatible with compact x-ray sources, which is a key requirement for the majority of clinical x-ray modalities. However, these methods are substantially limited by the need for mechanical phase stepping. We describe an electromagnetic phase stepping method that eliminates mechanical motion, and thus removing the constraints in speed, accuracy and flexibility. The method is broadly applicable to both projection and tomography imaging modes. The transition from mechanical to electromagnetic scanning should greatly facilitate the translation of x-ray phase contrast techniques into mainstream applications.