Researcher profile

Guy Ron

Guy Ron contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2020arXiv

$^{23}$Ne Production at SARAF-I

In this article, we present a measurement of flow rate, yield and effusion time of a $^{23}$Ne production and transport system. We used an accelerator-driven Li(d,n) neutron source to produce neutrons up to 20 MeV. The radioactive atoms were produced by a $^{23}$Na(n,p) reaction at a NaCl target. Later, the atoms were diffused out from the NaCl crystals and effused from the production chamber via a 10 m hose to a measurement cell and their decay products were detected using high purity germanium (HPGe) and plastic scintillator detectors. The resulting flow rate was $6.9\pm0.5\cdot 10^4\sfrac{atoms}{sec}$ and the total yield was $3.2\pm0.4\cdot10^{-9}\sfrac{atoms}{deuteron}$. We summarize our methods and estimates of efficiencies, rates of production and effusion.

preprint2020arXiv

A decay microscope for trapped neon isotopes

We review the design, simulation, and tests, of a detection system for measuring the energy distribution of daughter nuclei recoiling from the beta-decay of laser trapped neon isotopes. This distribution is sensitive to several new physics effects in the weak sector. Our `decay microscope' relies on imaging the velocity distribution of high energy recoil ions in coincidence with electrons shaken-off in the decay. We demonstrate by way of Monte-Carlo simulation, that the nuclear microscope increases the statistical sensitivity of kinematic measurements to the underlying energy distribution, and limits the main systematic bias caused by discrepancy in the trap position along the detection axis.

preprint2020arXiv

Polarization transfer to bound protons measured by quasi-elastic electron scattering on $^{12}$C

We report the measurements of the transverse ($P'x$) and longitudinal ($P'z$) components of the polarization transfer to a bound proton in carbon via the quasi-free $^{12}{\rm C}(\vec e,e'\vec p)$ reaction, over a wide range of missing momenta. We determine these polarization-transfers separately for protons knocked out from the $s$- and $p$-shells. The electron-beam polarization was measured to determine the individual components with systematic uncertainties which allow a detailed comparison with theoretical calculations.

preprint2020arXiv

The SPOT-IL Positron Beam Construction and Its Use for Doppler Broadening Measurement of Titanium Thin Films

The construction and first operation of the slow positron beam built at the Hebrew University is reported here. The beam follows a traditional design, using a 22Na source, a Tungsten moderator, and a target cell equipped with a load-lock system for easy sample insertion. The beam energy varies between 0.03 keV and 30 keV. The detection system consists of two high purity Germanium detectors, facing each other, allowing low-background Doppler-Broadening (DB) measurements. Event readout is done using a state-of-the-art compact desktop system. The target cell is designed to allow a combined measurement of DB and sample conductivity, with the flexibility to add more detection options in the future. The beam has been successfully tested by using it to charecterize Titanium (Ti) films. Two 1.2 μm Ti films -- as produced, and after annealing, were measured at various energies (2 keV - 25 keV), and the results show consistent behavior with previous measurements.