Source author record

Giovanni Mana

Giovanni Mana appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

26works
15topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

26 published item(s)

preprint2022arXiv

Neutron interference from a split-crystal interferometer

We report the first successful operation of a neutron interferometer having a separate beam recombining crystal. We achieved this result at the neutron interferometry setup S18 at the ILL in Grenoble by a collaboration between TU Wien, ILL Grenoble and INRIM Torino. While previous interferometers were machined out of a single crystal block, we managed to align two crystals on nanoradian and picometer scales, as required to obtain neutron interference. As a decisive proof of principle demonstration, it opens the door to a new generation of neutron interferometers and exciting applications.

preprint2022arXiv

The kilogram: inertial or gravitational mass?

With the redefinition of the international system of units, the value of the Planck constant was fixed, similarly to the values of the unperturbed ground state hyperfine transition frequency of the $^{133}$Cs atom, speed of light in vacuum. Theoretically and differently from the past, the kilogram is now explicitly defined as the unit of inertial mass. Experimentally, the kilogram is realized by atom count or the Kibble balance. We show that only the former method measures the inertial mass without assuming the universality of free fall. Therefore, the agreement between the two measures can be interpreted as a test of the equivalence principle.

preprint2021arXiv

Defocused travelling-fringes in scanning triple-Laue x-ray interferometry

The measurement of the silicon lattice parameter by a separate-crystal triple-Laue x-ray interferometer is a key step for the kilogram realisation by counting atoms. Since the measurement accuracy is approaching nine significant digits, a reliable model of the interferometer operation is demanded to quantify or exclude systematic errors. This paper investigates both analytically and experimentally the effect of defocus (a difference between the splitter-to-mirror distance on the one hand and the analyser-to-mirror one on the other) on the phase of the interference fringes and the measurement of the lattice parameter.

preprint2021arXiv

Measurement of the miscut angle in the determination of the Si lattice parameter

The measurement of the angle between the interferometer front mirror and the diffracting planes is a critical aspect of the Si lattice-parameter measurement by combined x-ray and optical interferometry. In addition to being measured off-line by x-ray diffraction, it was checked on-line by transversely moving the analyser crystal and observing the phase shift of the interference fringe. We describe the measurement procedure and give the miscut angle of the $^{28}$Si crystal whose lattice parameter was an essential input-datum for, yesterday, the determination of the Avogadro constant and, today, the kilogram realisation by counting atoms. These data are a kindness to others that might wish to repeat the measurement of the lattice-parameter of this unique crystal.

preprint2020arXiv

A more accurate measurement of the $^{28}$Si lattice parameter

In 2011, a discrepancy between the values of the Planck constant measured by counting Si atoms and by comparing mechanical and electrical powers prompted a review, among others, of the measurement of the spacing of $^{28}$Si {220} lattice planes, either to confirm the measured value and its uncertainty or to identify errors. This exercise confirmed the result of the previous measurement and yields the additional value $d_{220}=192014711.98(34)$ am having a reduced uncertainty.

preprint2020arXiv

Model selection in the average of inconsistent data: an analysis of the measured Planck-constant values

When the data do not conform to the hypothesis of a known sampling-variance, the fitting of a constant to a set of measured values is a long debated problem. Given the data, fitting would require to find what measurand value is the most trustworthy. Bayesian inference is here reviewed, to assign probabilities to the possible measurand values. Different hypothesis about the data variance are tested by Bayesian model comparison. Eventually, model selection is exemplified in deriving an estimate of the Planck constant.

preprint2020arXiv

X-ray phase contrast topography to measure the surface stress and bulk strain in a silicon crystal

The measurement of the Si lattice parameter by x-ray interferometry assumes the use of strain-free crystals, which might not be true because of intrinsic stresses due to surface relaxation, reconstruction, and oxidation. We used x-ray phase-contrast topography to investigate the strain sensitivity to the finishing, annealing, and coating of the interferometer crystals.We assessed the topography capabilities by measuring the lattice strain due to films of copper deposited on the interferometer mirror-crystal. A byproduct has been the measurement of the surface stresses after complete relaxation of the coatings.

preprint2016arXiv

30Si Mole Fraction of a Silicon Material Highly Enriched in 28Si Determined by Instrumental Neutron Activation Analysis

The latest determination of the Avogadro constant, carried out by counting the atoms in a pure silicon crystal highly enriched in 28Si, reached the target 2x10-8 relative uncertainty required for the redefinition of the kilogram based on the Planck constant. The knowledge of the isotopic composition of the enriched silicon material is central; it is measured by isotope dilution mass spectrometry. In this work, an independent estimate of the 30Si mole fraction was obtained by applying a relative measurement protocol based on Instrumental Neutron Activation Analysis. The amount of 30Si isotope was determined by counting the 1266.1 keV gamma-photons emitted during the radioactive decay of the radioisotope 31Si produced via the neutron capture reaction 30Si(n,gamma)31Si. The x(30Si) = 1.043(19)x10-6 mol mol-1 is consistent with the value currently adopted by the International Avogadro Coordination.

preprint2016arXiv

Half-life of 31Si

Half-life values are widely used in nuclear chemistry to model the exponential decay of the quantified radionuclides. The analysis of existing data reveals a general lack of information on the performed experiments and an almost complete absence of uncertainty budgets. This is the situation for 31Si, the radionuclide produced via neutron capture reaction recently used to quantify trace amounts of 30Si in a sample of the silicon material highly enriched in 28Si and used for the determination of the Avogadro constant. In order to improve the quality of the now recommended 157.36(26) min value, we carried out repeated observations of the 31Si decay rate via gamma-ray spectrometry measurements. This paper reports the result we obtained, including details of the experiment and the evaluation of the uncertainty.

preprint2016arXiv

Model uncertainty and reference value of the Planck constant

Statistical parametric models are proposed to explain the values of the Planck constant obtained by comparing electrical and mechanical powers and by counting atoms in Si 28 enriched crystals. They assume that uncertainty contributions -- having heterogeneous, datum-specific, variances -- might not be included in the error budgets of some of the measured values. Model selection and model averaging are used to investigate data consistency, to identify a reference value of the Planck constant, and to include the model uncertainty in the error budget.

preprint2015arXiv

Covariant priors and model uncertainty

In the application of Bayesian methods to metrology, pre-data probabilities play a critical role in the estimation of the model uncertainty. Following the observation that distributions form Riemann's manifolds, methods of differential geometry can be applied to ensure covariant priors and uncertainties independent of parameterization. Paradoxes were found in multi-parameter problems and alternatives were developed; but, when different parameters are of interest, covariance may be lost. This paper overviews information geometry, investigates some key paradoxes, and proposes solutions that preserve covariance.

preprint2015arXiv

Diffraction effects in length measurements by laser interferometry

High-accuracy dimensional measurements by laser interferometers require corrections because of diffraction, which makes the effective fringe-period different from the wavelength of a plane (or spherical) wave $λ_0$. By using a combined X-ray and optical interferometer as a tool to investigate diffraction across a laser beam, we observed wavelength variations as large as $10^{-8}λ_0$. We show that they originate from the wavefront evolution under paraxial propagation in the presence of wavefront- and intensity-profile perturbations.

preprint2015arXiv

The correlation of the $N_A$ measurements by counting $^{28}$Si atoms

An additional value of the Avogadro constant was obtained by counting the atoms in isotopically enriched Si spheres. With respect to the previous determination, the spheres were etched and repolished to eliminate metal contaminations and to improve the roundness. In addition, all the input quantities -- molar mass, lattice parameter, mass, and volume -- were remeasured aiming at a smaller uncertainty. In order to make the values given Refs.\ 1 and 2 usable for a least squares adjustment, we report about the estimate of their correlation.

preprint2014arXiv

Lattice strain at c-Si surfaces: a density functional theory calculation

The measurement of the Avogadro constant by counting Si atoms is based on the assumption that Si balls of about 94 mm diameter have a perfect crystal structure up to the outermost atom layers. This not the case because of the surface relaxation and reconstruction, the possible presence of an amorphous layer, and the oxidation process due to the interaction with the ambient. This paper gives the results of density functional calculations of the strain components orthogonal to crystal surface in a number of configurations likely found in real samples.

preprint2014arXiv

Neutron activation analysis of the 30Si content of highly enriched 28Si: proof of concept and estimation of the achievable uncertainty

We investigated the use of neutron activation to estimate the 30Si mole fraction of the ultra-pure silicon material highly enriched in 28Si for the measurement of the Avogadro constant. Specifically, we developed a relative method based on Instrumental Neutron Activation Analysis and using a natural-Si sample as a standard. To evaluate the achievable uncertainty, we irradiated a 6 g sample of a natural-Si material and modeled experimentally the signal that would be produced by a sample of the 28Si-enriched material of similar mass and subjected to the same measurement conditions. The extrapolation of the expected uncertainty from the experimental data indicates that a measurement of the 30Si mole fraction of the 28Si-enriched material might reach a 4% relative combined standard uncertainty.

preprint2014arXiv

The distribution of the electric current in a watt-balance coil

In the watt balance experiments, separate measurements of the magnetic and electromotive forces in a coil in a magnetic field enable a virtual comparison between mechanical and electric powers to be carried out, which lead to an accurate measurement of the Planck constant. This paper investigates the three-dimensional nature of the coil-field interaction and describes the balance operation by a continuous three-dimensional model.

preprint2013arXiv

Bayesian estimate of the degree of a polynomial given a noisy data sample

A widely used method to create a continuous representation of a discrete data-set is regression analysis. When the regression model is not based on a mathematical description of the physics underlying the data, heuristic techniques play a crucial role and the model choice can have a significant impact on the result. In this paper, the problem of identifying the most appropriate model is formulated and solved in terms of Bayesian selection. Besides, probability calculus is the best way to choose among different alternatives. The results obtained are applied to the case of both univariate and bivariate polynomials used as trial solutions of systems of thermodynamic partial differential equations.

preprint2013arXiv

Elemental characterization of the Avogadro silicon crystal WASO 04 by neutron activation analysis

Analytical measurements of the 28Si crystal used for the determination of the Avogadro constant are essential to prevent biased results or under-estimated uncertainties. A review of the existing data confirms the high-purity of silicon with respect to a large number of elements. In order to obtain a direct evidence of purity, we developed a relative analytical method based on neutron activation. As a preliminary test, this method was applied to a sample of the Avogadro crystal WASO 04. The investigation concerned twenty-nine elements. The mass fraction of Au was quantified to be 1.03(18) x 10-12. For the remaining twenty-eight elements, the mass fractions are below the detection limits, which range between 1 x 10-12 and 1 x 10-5.

preprint2013arXiv

Finite element analysis of surface-stress effects in the Si lattice-parameter measurement

A stress exists in solids surfaces, similarly to liquids, also if the underlying bulk material is stress-free. This paper investigates the surface stress effect on the measured value of the Si lattice parameter used to determine the Avogadro constant by counting Si atoms. An elastic-film model has been used to provide a surface load in a finite element analysis of the lattice strain of the x-ray interferometer crystal used to measure the lattice parameter. Eventually, an experiment is proposed to work a lattice parameter measurement out so that there is a visible effect of the surface stress.

preprint2013arXiv

Precision measurements of the Planck and Avogadro constants

Precision measurements of the fundamental constants are tour de force of basic metrology, where the useful information is usually beyond the last digit of the measured value. They challenge theoretical models and measurement technologies and set a network of measurement equations on which a universal system of units can be built, which stems from the most basic concepts of physics. Because of their connection with the mass unit, the Avogadro and Planck constants are on the spotlight.

preprint2011arXiv

Does the measured value of the Planck constant depend on the energy of measurements?

The measurement of the Avogadro constant opened the way to a comparison of the watt-balance measurements of the Planck constant with the values calculated from the quotients of the Planck constant and the mass of a particle or an atom. Since the energy scales of these measurements span nine energy decades, these data provide insight into the consistency of our understanding of physics.

preprint2011arXiv

On the average of inconsistent data

When data do not conform to the hypothesis of a known sampling-variance, the fitting of a constant to the set of measured values is a long debated problem. Given the data, the fitting would require to find which measurand value is most probable. A fitting procedure is here reviewed which assigns probabilities to the possible measurand values, on the assumption that the uncertainty associated with each datum is the lower bound to the standard deviation. This procedure is applied to derive an estimate of the Planck constant.

preprint2010arXiv

Measurement of the \{220\} lattice-plane spacing of a $^{28}$Si crystal

The spacing of the \{220\} lattice planes of a $^{28}$Si crystal was measured by combined x-ray and optical interferometry to a $3.5\times 10^{-9}$ relative accuracy. The result is $d_{220}=(192014712.67 \pm 0.67)$ am, at 20.0 $^\circ$C and 0 Pa. This value is greater by $(1.9464 \pm 0.0067)\times 10^{-9} d_{220}$ than the spacing in natural Si, a difference which confirms quantum mechanics calculations. Subsequently, this crystal has been used to determine the Avogadro constant by counting the Si atoms, a key step towards a realization of the mass unit based on a conventional value of the Planck or the Avogadro constants.