Researcher profile

Giorgio Gratta

Giorgio Gratta contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
6works
0followers
9topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2022arXiv

Librational Feedback Cooling

Librational motion, whereby a rigid body undergoes angular oscillation around a preferred direction, can be observed in optically trapped, silica microspheres. We demonstrate the cooling of one librational degree of freedom for $\sim 5~μ$m diameter spheres that have been induced to rotate with an external electric field coupled to their electric dipole moment. Cooling is accomplished by adding a phase modulation to the rotating field. The degree of cooling is quantified by applying a $π/2$ shift to the phase of the electric field and fitting the resulting exponential decay of the librational motion to obtain a damping time, as well as estimating a mode temperature from the observed libration in equilibrium. The result is an important step in the study of the dynamics of trapped microspheres, crucial to cooling the mechanical motion to its ground state, as well as providing insights regarding the charge mobility in the material at microscopic scales.

preprint2020arXiv

A Tetramethylsilane TPC with Cherenkov light readout and 3D reconstruction

We describe the construction and calibration of a multi-channel liquid time projection chamber filled with Tetramethylsilane (TMS). Its charge readout system consists of 8 wires each in the $X$ and $Y$ directions. The chamber is also equipped with a Cherenkov light readout system consisting of a 5-inch photomultiplier tube (PMT) coupled to the liquid volume through a viewport. The energy scale of the detector is calibrated using positron-electron pairs produced by 4.4 MeV gamma rays emitted from an AmBe source, using an external trigger on the positron annihilation gammas. The external trigger is then reconfigured to tag cosmic ray muons passing through the active TMS volume, which are used to measure the stopping power in TMS and the electron lifetime in the detector. We find a most-probable energy loss from minimum ionising particles (MIPs) of $Δ_p/ds$ = (0.60$\pm$0.01) MeV/cm. We also derive an electron lifetime of 43$^{+680}_{-21}~μ$s by measuring the most-probable energy loss as a function of drift time. For both fast electron and muon signals, the PMT detects prompt Cherenkov light, demonstrating the possibility of random triggering. The room-temperature organic target medium, together with the self-triggering capabilities and long electron lifetimes reported in this work, make this an attractive technology to further explore for rare event detectors or other applications in the area of radiation measurements.

preprint2020arXiv

Absolute pressure and gas species identification with an optically levitated rotor

The authors describe a novel variety of spinning-rotor vacuum gauge in which the rotor is a ${\sim}4.7{\text -}μ$m-diameter silica microsphere, optically levitated. A rotating electrostatic field is used to apply torque to the permanent electric dipole moment of the silica microsphere and control its rotational degrees of freedom. When released from a driving field, the microsphere's angular velocity decays exponentially with a damping time inversely proportional to the residual gas pressure, and dependent on gas composition. The gauge is calibrated by measuring the rotor mass with electrostatic co-levitation, and assuming a spherical shape, confirmed separately, and uniform density. The gauge is cross-checked against a capacitance manometer by observing the torsional drag due to a number of different gas species. The techniques presented can be used to perform absolute vacuum measurements localized in space, owing to the small dimensions of the microsphere and the ability to translate the optical trap in three dimensions, as well as measurements in magnetic field environments. In addition, the dynamics of the microsphere, paired with a calibrated vacuum gauge, can be used to measure the effective molecular mass of a gas mixture without the need for ionization and at pressures up to approximately 1 mbar.

preprint2020arXiv

High sensitivity, levitated microsphere apparatus for short-distance force measurements

A high sensitivity force sensor based on dielectric microspheres in vacuum, optically trapped by a single, upward-propagating laser beam, is described. Off-axis parabolic mirrors are used both to focus the 1064~nm trapping beam and to recollimate it to provide information on the horizontal position of the microsphere. The vertical degree of freedom is readout by forming an interferometer between the light retroreflected by the microsphere and a reference beam, hence eliminating the need for auxiliary beams. The focus of the trapping beam has a 1/e$^2$ radius of 3.2~$μ$m and small non-Gaussian tails, suitable for bringing devices close to the trapped microsphere without disturbing the optical field. Electrodes surrounding the trapping region provide excellent control of the electric field, which can be used to drive the translational degrees of freedom of a charged microsphere and the rotational degrees of freedom of a neutral microsphere, coupling to its electric dipole moment. With this control, the charge state can be determined with single electron precision, the mass of individual microspheres can be measured, and empirical calibrations of the force sensitivity can be made for each microsphere. A force noise of $<1\times10^{-17}$~N/$\sqrt{\rm Hz}$, which is comparable to previous reports, is measured on all three degrees of freedom for 4.7~$μ$m diameter, 84~pg silica microspheres. Various devices have been brought within $1.6~μ$m of the surface of a trapped microsphere. Metrology in the trapping region is provided by two custom-designed microscopes providing views in the horizontal and one of the vertical planes. The apparatus opens the way to performing high sensitivity three-dimensional force measurements at short distance.

preprint2020arXiv

Quantum Detection using Magnetic Avalanches in Single-Molecule Magnets

The detection of a single quantum of energy with high efficiency and low false positive rate is of considerable scientific interest, from serving as single quantum sensors of optical and infra-red photons to enabling the direct detection of low-mass dark matter. We report the first experimental demonstration of magnetic avalanches induced by scattering of quanta in single-molecule magnet (SMM) crystals made of Mn12-acetate, establishing the use of SMMs as particle detectors for the first time. While the current setup has an energy threshold in the MeV regime, our results motivate the exploration of a wide variety of SMMs whose properties could allow for detection of sub-eV energy depositions.

preprint2020arXiv

Searching for New Interactions at Sub-micron Scale Using the Mossbauer Effect

A new technique to search for new scalar and tensor interactions at the sub-micrometer scale is presented. The technique relies on small shifts of nuclear gamma lines produced by the coupling between matter and the nuclei in the source or absorber of a Mossbauer spectrometer. Remarkably, such energy shifts are rather insensitive to electromagnetic interactions that represent the largest background in searches for new forces using atomic matter. This is because nuclei are intrinsically shielded by the electron clouds. Additionally, electromagnetic interactions cause energy shifts by coupling to nuclear moments that are suppressed by the size of the nuclei, while new scalar interactions can directly affect these shifts. Finally, averaging over unpolarized nuclei, further reduces electromagnetic interactions. We discuss several possible configurations, using the traditional Mossbauer effect as well as nuclear resonant absorption driven by synchrotron radiation. For this purpose, we examine the viability of well known Mossbauer nuclides along with more exotic ones that result in substantially narrower resonances. We find that the technique introduced here could substantially improve the sensitivity to a variety of new interactions and could also be used, in conjunction with mechanical force measurements, to corroborate a discovery or explore the new physics that may be behind a discovery.