Source author record

G. Das

G. Das appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2020arXiv

Approximate four-loop QCD corrections to the Higgs-boson production cross section

We study the soft and collinear (SV) contributions to inclusive Higgs-boson production in gluon-gluon fusion at four loops. Using recent progress for the quark and gluon form factors and Mellin moments of splitting functions, we are able to complete the soft-gluon enhanced contributions exactly in the limit of a large number of colours, and to a sufficiently accurate numerical accuracy for QCD. The four-loop SV contributions increase the QCD cross section at 14 TeV by 2.7% and 0.2% for the standard choices mu_R=m_H and mu_R=m_H/2 of the renormalization scale, and reduce the scale uncertainty to below +-3%. As by-products, we derive the complete delta(1-x) term for the gluon-gluon splitting function at four loops and its purely Abelian contributions at five loops, and provide a numerical result for the single pole of the four-loop gluon form factor in dimensional regularization. Finally we present the closely related fourth-order coefficients D_4 for the soft-gluon exponentiation of Higgs-boson and Drell-Yan lepton-pair production.

preprint2016arXiv

Study of Performance of Bakelite Resistive Plate Chamber (RPC)

Resistive Plate Chamber (RPC) is a type of gaseous detector having excellent time and position resolutions. VECC is involved in the R\&D of indigenously developed bakelite RPCs. The largest size of bakelite RPC developed in India is 100 cm $\times$ 100 cm. We present here the test results of a bakelite sample along with the cosmic ray test results of a bakelite RPC (30 cm $\times$ 30 cm $\times$ 0.2cm) fabricated at VECC. The steps taken towards the development of a large size (240 cm $\times$ 120 cm $\times$ 0.2 cm) bakelite RPC have also been discussed.

preprint2014arXiv

Development of Multi-gap Resistive Plate Chamber (MRPC) for medical imaging

The low cost and high resolution Multi-gap Resistive Plate Chamber (MRPC) opens up a new possibility to find an efficient alternative detector for the Time of Flight (TOF) based Positron Emission Tomography, where the sensitivity of the system depends largely on the time resolution of the detector. In a layered structure, suitable converters can be used to increase the photon detection efficiency. In this paper results of the cosmic ray test of a four-gap bakelite-based prototype MRPC operated in streamer mode and six-gap glass-based MRPC operated in avalanche mode are discussed.

preprint2012arXiv

Measurement of electrical properties of electrode materials for the bakelite Resistive Plate Chambers

Single gap (gas gap 2 mm) bakelite Resistive Plate Chamber (RPC) modules of various sizes from 10 cm \times 10 cm to 1 m \times 1 m have been fabricated, characterized and optimized for efficiency and time resolution. Thin layers of different grades of silicone compound are applied to the inner electrode surfaces to make them smooth and also to reduce the surface resistivity. In the silicone coated RPCs an efficiency > 90% and time resolution \sim 2 ns (FWHM) have been obtained for both the streamer and the avalanche mode of operation. Before fabrication of detectors the electrical properties such as bulk resistivity and surface resistivity of the electrode materials are measured carefully. Effectiveness of different silicone coating in modifying the surface resistivity was evaluated by an instrument developed for monitoring the I-V curve of a high resistive surface. The results indicate definite correlation of the detector efficiency for the atmospheric muons and the RPC noise rates with the surface resistivity and its variation with the applied bias voltage. It was also found that the surface resistivity varies for different grades of silicone material applied as coating, and the results are found to be consistent with the detector efficiency and noise rate measurements done with these RPCs.