Source author record

Ferruccio Renzoni

Ferruccio Renzoni appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

11works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

11 published item(s)

preprint2020arXiv

Sub-Sm$^{-1}$ electromagnetic induction imaging with an unshielded atomic magnetometer

Progress in electromagnetic induction imaging with atomic magnetometers has brought its domain to the edge of the regime useful for biomedical imaging. However, a demonstration of imaging below the required 1 Sm$^{-1}$ level is still missing. In this Letter, we use an $^{87}$Rb radio-frequency atomic magnetometer operating near room temperature in an unshielded environment to image calibrated solutions mimicking the electric conductivity of live tissues. By combining the recently introduced near-resonant imaging technique with a dual radio-frequency coil excitation scheme, we image 5 mL of solutions down to 0.9 Sm$^{-1}$. We measure a signal-to-noise ratio of 2.7 at 2 MHz for 0.9 Sm$^{-1}$, increased up to 7.2 with offline averaging. Our work is an improvement of 50 times on previous imaging results, and demonstrates the sensitivity and stability in unshielded environments required for imaging biological tissues, in particular for the human heart.

preprint2016arXiv

Compact setup for the production of $^{87}$Rb $|F = 2, m_F = +2\rangle$ Bose-Einstein condensates in a hybrid trap

We present a compact experimental apparatus for Bose-Einstein condensation of $^{87}$Rb in the $|F = 2, m_F = +2\rangle$ state. A pre-cooled atomic beam of $^{87}$Rb is obtained by using an unbalanced magneto-optical trap, allowing controlled transfer of trapped atoms from the first vacuum chamber to the science chamber. Here, atoms are transferred to a hybrid trap, as produced by overlapping a magnetic quadrupole trap with a far-detuned optical trap with crossed beam configuration, where forced radiofrequency evaporation is realized. The final evaporation leading to Bose-Einstein condensation is then performed by exponentially lowering the optical trap depth. Control and stabilization systems of the optical trap beams are discussed in detail. The setup reliably produces a pure condensate in the $|F = 2, m_F = +2\rangle$ state in 50 s, which include 33 s loading of the science magneto-optical trap and 17 s forced evaporation.

preprint2016arXiv

Electromagnetic Imaging with Atomic Magnetometers: A Novel Approach to Security and Surveillance

We describe our research programme on the use of atomic magnetometers to detect conductive objects via electromagnetic induction. The extreme sensitivity of atomic magnetometers at low frequencies, up to seven orders of magnitude higher than a coil-based system, permits deep penetration through different media and barriers, and in various operative environments. This eliminates the limitations usually associated with electromagnetic detection.

preprint2016arXiv

Electromagnetic induction imaging with a radio-frequency atomic magnetometer

We report on a compact, tunable, and scalable to large arrays imaging device, based on a radio-frequency optically pumped atomic magnetometer operating in magnetic induction tomography modality. Imaging of conductive objects is performed at room temperature, in an unshielded environment and without background subtraction. Conductivity maps of target objects exhibit not only excellent performance in terms of shape reconstruction but also demonstrate detection of sub-millimetric cracks and penetration of conductive barriers. The results presented here demonstrate the potential of a future generation of imaging instruments, which combine magnetic induction tomography and the unmatched performance of atomic magnetometers.

preprint2016arXiv

Optical atomic magnetometry for magnetic induction tomography of the heart

We report on the use of radio-frequency optical atomic magnetometers for magnetic induction tomography measurements. We demonstrate the imaging of dummy targets of varying conductivities placed in the proximity of the sensor, in an unshielded environment at room-temperature and without background subtraction. The images produced by the system accurately reproduce the characteristics of the actual objects. Furthermore, we perform finite element simulations in order to assess the potential for measuring low-conductivity biological tissues with our system. Our results demonstrate the feasibility of an instrument based on optical atomic magnetometers for magnetic induction tomography imaging of biological samples, in particular for mapping anomalous conductivity in the heart.

preprint2015arXiv

Universal asymptotic behavior in nonlinear systems driven by a two-frequency forcing

We examine the time-dependent behavior of a nonlinear system driven by a two-frequency forcing. By using a non-perturbative approach, we are able to derive an asymptotic expression, valid in the long-time limit, for the time average of the output variable which describes the response of the system. We identify several universal features of the asymptotic response of the system, which are independent of the details of the model. In particular, we determine an asymptotic expression for the width of the resonance observed by keeping one frequency fixed, and varying the other one. We show that this width is smaller than the usually assumed Fourier width by a factor determined by the two driving frequencies, and independent of the model system parameters. Additional general features can also be identified depending on the specific symmetry properties of the system. Our results find direct application in the study of sub-Fourier signal processing with nonlinear systems.

preprint2014arXiv

Irrationality and quasiperiodicity in driven nonlinear systems

We analyse the relationship between irrationality and quasiperiodicity in nonlinear driven systems. To that purpose we consider a nonlinear system whose steady-state response is very sensitive to the periodic or quasiperiodic character of the input signal. In the infinite time limit, an input signal consisting of two incommensurate frequencies will be recognised by the system as quasiperiodic. We show that this is in general not true in the case of finite interaction times. An irrational ratio of the driving frequencies of the input signal is not sufficient for it to be recognised by the nonlinear system as quasiperiodic, resulting in observations which may differ by several orders of magnitude from the expected quasiperiodic behavior. Thus, the system response depends on the nature of the irrational ratio, as well as the observation time. We derive a condition for the input signal to be identified by the system as quasiperiodic. Such a condition also takes into account the sub-Fourier response of the nonlinear system.

preprint2014arXiv

Magnetic induction tomography using an all-optical $^{87}$Rb atomic magnetometer

We demonstrate Magnetic Induction Tomography (MIT) with an all-optical atomic magnetometer. Our instrument creates a conductivity map of conductive objects. Both shape and size of the imaged samples compare very well with the actual shape and size. Given the potential of all-optical atomic magnetometers for miniaturization and extreme sensitivity, the proof-of-principle presented here opens up promising avenues in the development of instrumentation for magnetic induction tomography.

preprint2013arXiv

Collective strong coupling in multimode cavity QED

We study an atom-cavity system in which the cavity has several degenerate transverse modes. Mode-resolved cavity transmission spectroscopy reveals well-resolved atom-cavity resonances for several cavity modes, a signature of collective strong coupling for the different modes. Furthermore, the experiment shows that the cavity modes are coupled via the atomic ensemble contained in the cavity. The experimental observations are supported by a detailed theoretical analysis. The work paves the way to the use of interacting degenerate modes in cavity-based quantum information processing, where qubits corresponding to different cavity modes interact via an atom shared by the two modes. Our results are also relevant to the experimental realization of quantum spin glasses with ultracold atoms.

preprint2013arXiv

Control of transport in higher dimensional systems via dynamical decoupling of degrees of freedom with quasiperiodic driving fields

We consider the problem of the control of transport in higher dimensional periodic structures by applied ac fields. In a generic crystal, transverse degrees of freedom are coupled, and this makes the control of motion difficult to implement. We show, both with simulations and with an analytical functional expansion on the driving amplitudes, that the use of quasiperiodic driving significantly suppresses the coupling between transverse degrees of freedom. This allows a precise control of the transport, and does not require a detailed knowledge of the crystal geometry.

preprint2013arXiv

Magnetic induction measurements using an all-optical $^{87}$Rb atomic magnetometer

In this work we propose, and experimentally demonstrate, the use of a self-oscillating all-optical atomic magnetometer for magnetic induction measurements. Given the potential for miniaturization of atomic magnetometers, and their extreme sensitivity, the present work shows that atomic magnetometers may play a key role in the development of instrumentation for magnetic induction tomography.